Preferred Language
Articles
/
ijcpe-416
Differences Between Sodium Metasilicate and Silicic Acid as Silica Source for Zeolite Y Nano particles Synthesis by Sol- Gel Method
...Show More Authors

Zeolite Y nanoparticles were synthesized by sol - gel method. Dffirent samples using two silica sources were prepared.
Sodium metasilicate (Na2SiO3) (48% silica) and silicic acid silica (H2SiO3) (75% silica) were employed as silica
source and aluminum nitrate (Al(NO3)3.9H2O) was the aluminum source with tetrapropylammonium hydroxide
(TPAOH) as templating agent.
The synihesized-samples were characterized by X-ray diffraction, showed the requirement of diffirent aging time for
complete crystallization to be achieved. Transmission Electronic Microscope (TEM) images, showed the particles were
in the same range of 30 - 75 nm. FT-IR spectroscory, showed the synthesized samples having the zeolite Y crystal
properties. The initial mixing silica to alumina ratio (SiO2/Al2O3) was 10, but, sodium metasilicate sample was of 2.55
final ratio, while silicic acid sample have 18.41 and the surface area as tested by BET was of 555.87 m2/g from sodium
metasilicate sample and 276.3 m2/g from silicic acid sample.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 17 2011
Journal Name
Environmental Earth Sciences
Geochemistry and mineralogical composition of the airborne particles of sand dunes and dust storms settled in Iraq and their environmental impacts
...Show More Authors

View Publication
Crossref (38)
Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Analytica Chimica Acta
A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry
...Show More Authors

The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column

... Show More
View Publication
Scopus (32)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Wed Jun 21 2017
Journal Name
Research Journal Of Pharmaceutical, Biological And Chemical Sciences
Synthesis and characterization of Mixed-Ligand Complexes of Oxalic Acid and Trimethoprim with Mn(II), Co(II), Ni(II), Cu(II),Zn(II), and Cr (III) Ions: and antimicrobial Activities
...Show More Authors

Publication Date
Sun Jan 01 2012
Journal Name
Advances In Physics Theories And Applications
Synthesis, Characterization, And Antibacterial Activities Of Manganese (II), Cobalt(II), Iron (II), Nickel (II) , zinc (II) And Cadmium(II) Mixed- Ligand Complexes Containing Amino Acid(L-Valine) And Saccharin
...Show More Authors

new six mixed ligand complexes of some transition metal ions Manganese (II), Cobalt(II), Iron (II), Nickel (II) , and non transition metal ion zinc (II) And Cadmium(II) with L-valine (Val H ) as a primary ligand and Saccharin (HSac) as a secondary ligands have been prepared. All the prepared complexes have been characterized by molar conductance, magnetic susceptibility infrared, electronic spectral, Elemental microanalysis (C.H.N) and AA . The complexes with the formulas [M(Val)2(HSac)2] M= Mn (II) , Fe (II) , Co(II) ,Ni(II), Cu (II),Zn(II) and Cd(II) L- Val H= (C5H11NO2) , C7H5NO3S The study shows that these complexes have octahedral geometry; The metal complexes have been screened for their in microbiological activities against bacteria.

... Show More
Publication Date
Wed Jan 01 2025
Journal Name
Journal Of Advanced Pharmacy Education And Research
Ultra HPLC method development and validation for the determination of meclizine in pharmaceutical formulation
...Show More Authors

View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jun 07 2009
Journal Name
Baghdad Science Journal
A New Spectrophotometric Method for Analysis of Allopurinol in Aqueous Solutions and Pharmaceutical Preparations
...Show More Authors

A new method for determination of allopurinol in microgram level depending on its ability to reduce the yellow absorption spectrum of (I-3) at maximum wavelength ( ?max 350nm) . The optimum conditions such as "concentration of reactant materials , time of sitting and order of addition were studied to get a high sensitivity ( ? = 27229 l.mole-1.cm-1) sandal sensitivity : 0.0053 µg cm-2 ,with wide range of calibration curve ( 1 – 9 µg.ml-1 ) good stability (more then24 hr.) and repeatability ( RSD % : 2.1 -2.6 % ) , the Recovery % : ( 98.17 – 100.5 % ) , the Erel % ( 0.50 -1.83 % ) and the interference's of Xanthine , Cystein , Creatinine , Urea and the Glucose in 20 , 40 , 60 fold of analyate were also studied .

View Publication Preview PDF
Crossref
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Medicinal And Chemical Sciences
Simple Spectrophotometric Method for Determination of Drug Lisinopril in Pure Form and Pharmaceutical Formulations
...Show More Authors

Scopus (2)
Scopus
Publication Date
Tue Feb 21 2017
Journal Name
Biomechanics And Modeling In Mechanobiology
A novel method for non-invasively detecting the severity and location of aortic aneurysms
...Show More Authors

The influence of an aortic aneurysm on blood flow waveforms is well established, but how to exploit this link for diagnostic purposes still remains challenging. This work uses a combination of experimental and computational modelling to study how aneurysms of various size affect the waveforms. Experimental studies are carried out on fusiform-type aneurysm models, and a comparison of results with those from a one-dimensional fluid–structure interaction model shows close agreement. Further mathematical analysis of these results allows the definition of several indicators that characterize the impact of an aneurysm on waveforms. These indicators are then further studied in a computational model of a systemic blood flow network. This demonstr

... Show More
View Publication Preview PDF
Scopus (34)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Cooling Load Calculations For Typical Iraqi Roof And Wall Constructions Using Ashrae's RTS Method
...Show More Authors

The present work is an attempt to develop design data for an Iraqi roof and wall constructions using the latest ASHRAE Radiant Time Series (RTS) cooling load calculation method. The work involves calculation of cooling load theoretically by introducing the design data for Iraq, and verifies the results experimentally by field measurements. Technical specifications of Iraqi construction materials are used to derive the conduction time factors that needed in RTS method calculations. Special software published by Oklahoma state university is used to extract the conduction factors according to the technical specifications of Iraqi construction materials.  Good agreement between the average theoretical and measured cooli

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 30 2018
Journal Name
Iraqi Journal Of Medical Sciences
CLINICAL UTILITY OF URINARY ANTIGEN TEST AND MOLECULAR METHOD FOR DETECTION OF LEGIONELLA PNEUMOPHILA
...Show More Authors

Background: Legionella pneumophila (L. pneumophila) is gram-negative bacterium, which causes Legionnaires’ disease as well as Pontiac fever. Objective: To determine the frequency of Legionella pneumophila in pneumonic patients, to determine the clinical utility of diagnosing Legionella pneumonia by urinary antigen testing (LPUAT) in terms of sensitivity and specificity, to compares the results obtained from patients by urinary antigen test with q Real Time PCR (RT PCR) using serum samples and to determine the frequency of serogroup 1 and other serogroups of L. pneumophila. Methods: A total of 100 pneumonic patients (community acquired pneumonia) were enrolled in this study during a period between October 2016 to April 2017; 92 sam

... Show More
View Publication Preview PDF
Crossref