A field Experiment was carried out in Baghdad for the purpose of compare five horticulture machines during used two types of fuel deffirance in octane number, normal and super fuel which produced in Iraqi and measuring the vibrations transmitted of the three axes are longitudinal X , lateral Y and vertical Z from handlebar in (Mowers) to the operator which walks behind the mower, and the determine of the productivity practical of cutting, productivity passing and fuel consumption. Experiment Factorial used with two factors, The first factor was Five Mowers vary in width , types, weight and company manufacturer, The Second factor was the types of fuel used internal combination engine horticulture mowers were Normal fuel with Octane Number 82 and super fuel with Octane Number 95, according to randomized complete block design were used in this experiment with three replication . Least Significant Design (LSD) 0.05 was used to compare the mean of treatments. The result showed mower A type John Deer recorded the lowest vibration values in longitudinal, lateral, vertical and resultant whole vibration 5.21, 2.55, 3.85 and 6.97 m/sec² , higher productivity practical cutting 1160 m²/hr, higher productivity passing 128 kg/donam and least fuel consumption 1.378 L/donam. Super fuel recorded lowest longitudinal, lateral, vertical and resultant whole vibrations 4.63, 2.53, 3.86 and 6.54 m/sec², higher productivity practical cutting 1045 m²/hr and least fuel consumption 1.446 L/donam. The Result in the five mowers exceeded the legislated permissible vibration exposure limits in the worldwide.
This study's objective is to assess how well UV spectrophotometry can be used in conjunction with multivariate calibration based on partial least squares (PLS) regression for concurrent quantitative analysis of antibacterial mixture (Levofloxacin (LIV), Metronidazole (MET), Rifampicin (RIF) and Sulfamethoxazole (SUL)) in their artificial mixtures and pharmaceutical formulations. The experimental calibration and validation matrixes were created using 42 and 39 samples, respectively. The concentration range taken into account was 0-17 μg/mL for all components. The calibration standards' absorbance measurements were made between 210 and 350 nm, with intervals of 0.2 nm. The associated parameters were examined in order to develop the optimal c
... Show MoreIn this paper, suggested method as well as the conventional methods (probability
plot-(p.p.) for estimations of the two-parameters (shape and scale) of the Weibull
distribution had proposed and the estimators had been implemented for different
sample sizes small, medium, and large of size 20, 50, and 100 respectively by
simulation technique. The comparisons were carried out between different methods
and sample sizes. It was observed from the results that suggested method which
were performed for the first time (as far as we know), by using MSE indicator, the
comparisons between the studied and suggested methods can be summarized
through extremely asymptotic for indicator (MSE) results by generating random
error
The two dimensional steady, combined forced and natural convection in vertical channel is
investigated for laminar regime. To simulate the Trombe wall channel geometry properly, horizontal
inlet and exit segments have been added to the vertical channel. The vertical walls of the channel are
maintained at constant but different temperature while horizontal walls are insulated. A finite
difference method using up-wind differencing for the nonlinear convective terms, and central
differencing for the second order derivatives, is employed to solve the governing differential
equations for the mass, momentum, and energy balances. The solution is obtained for stream
function, vorticity and temperature as dependent variables
In this paper a mathematical model that analytically as well as numerically
the flow of infection disease in a population is proposed and studied. It is
assumed that the disease divided the population into five classes: immature
susceptible individuals (S1) , mature individuals (S2 ) , infectious individual
(I ), removal individuals (R) and vaccine population (V) . The existence,
uniqueness and boundedness of the solution of the model are discussed. The
local and global stability of the model is studied. Finally the global dynamics of
the proposed model is studied numerically.
Many developments happened in Service Oriented architecture models but with no details in its technology and requirement. This paper presents a new Service Oriented Architecture (SOA) to all Service Enterprise (SE) according to their demands. Therefore, the goal is to build a new complete architecture model for SOA methodologies according to current technology and business requirements that could be used in a real Enterprise environment. To do this, new types of services and new model called Lego Model are explained in details, and the results of the proposed architecture model in analyzed. Consequently, the complications are reduced to support business domains of enterprise and to start associating SOA methodologies in their corporate s
... Show MoreHigh Q-factor based on absorption can be achieved by tuning (the reflection and the transition percentage). In this work, the simple design and simulated in S-band have been investigated. The simulation results of G-shape resonator are shown triple band of absorption peaks 60%, 91.5%, and 70.3%) at resonance frequency 2.7 GHz, 3.26 GHz, and 4.05 GHz respectively. The results exhibited very high of the Q-factor ( 271 ) at resonance frequency ( 3.26 GHz ). The high Q-factor can be used to enhance the sensor sensing, narrowband band filter and image sensing.
The study aims to assess some physical, chemical, and bacterial characteristics of two drinking water treatment plants of Al- Dora and Al-Qadisiya in the area of ​​Karkh, Baghdad, Iraq. The areas covered by each plants and these sites of areas selected as the nearest and the farthest point from plants, for winter and summer season. Some physicochemical parameters of water quality were taken in this study and these parameters were temperature water, pH, electrical conductivity, total dissolved solids, free residual chlorine, calcium, magnesium, nitrate, nitrite, sulphate and heavy metals (lead). In addition to four bacterial indicators of drinking water pollution (APC, Total Coliform, Fecal Coliform
... Show MoreThis research depends on the relationship between the reflected spectrum, the nature of each target, area and the percentage of its presence with other targets in the unity of the target area. The changes occur in Land cover have been detected for different years using satellite images based on the Modified Spectral Angle Mapper (MSAM) processing, where Landsat satellite images are utilized using two software programming (MATLAB 7.11 and ERDAS imagine 2014). The proposed supervised classification method (MSAM) using a MATLAB program with supervised classification method (Maximum likelihood Classifier) by ERDAS imagine have been used to get farthest precise results and detect environmental changes for periods. Despite using two classificatio
... Show MoreExpansive soil is one of the most serious problems that face engineers during the execution of any infrastructure projects. Soil stabilization using chemical admixture is one of the most traditional and widespread methods of soil improvement. Nevertheless, soil improvement on site is one of the most economical solutions for many engineering applications. Using construction and demolishing waste in soil stabilization is still under research., The aim of this study is to identify the effect of using concrete demolishing waste (CDW) in soil stabilization. Serious tests were conducted to investigate the changes in the geotechnical properties of the natural soil stabilized with CDW. From the results, it is concluded that the
... Show MoreThe climate parameters annual rainfall and average mean temperature are investigated from 2000 to 2019 for Kut, Hilla and Iskandaryia. Evidence of climate change is noticed by decreasing the mean annual rainfall and relative humidity with an increase in the annual mean temperature. The climate water balance has been calculated. Due to high temperature, increased evaporation, and low precipitation rates, there was a large water deficit. The total water surplus in the Kut area is 32.86 mm from November to February, and in Hilla and Iskandaryia is 20.4 and 27.8 mm from December to February, respectively. The climate classification for the three stations was semi-dry to dry climates. The region has a significant water deficit of u
... Show More