Preferred Language
Articles
/
huaVLZ4BmraWrQ4dbF97
Biomechanical finite element analysis of a single implant threaded in anterior and posterior regions of maxilla bone
...Show More Authors

Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two different regions of maxilla bone (anterior (type III bone) and posterior (type IV bone)). A 3D-CAD geometry of implant-maxilla bone was created through importing digitally visualized CT skull images of a human adult, and then converted into a workable solid body through using a collection of engineering software. Tapered and cylindrical implant models with three different implant V-shaped thread depths (0.25 mm, 0.35 mm, 0.45 mm) were threaded into maxilla bone to investigate the design parameters effect on the final stress status. The proposed implant was of commercial dimensions of 10 mm length and 4 mm in diameter. A vertical static load of 250N was directly applied to the center of the suprastructure of the implant for each model. Results: Evaluations were performed for stress distribution patterns and maximum equivalent Von Mises (EQV) stresses for implants in two regions of maxilla bone under 250N vertical static loading. The obtained results throughout this work showed that, for all models, the highest stresses were located at the crestal cortical bone around the implant neck. The von-Mises stress distribution patterns at different models were similar and higher peak von-Mises stresses of cortical bone were seen in tapered implant body compared to cylinder body in all models. Conclusions: Within the restrictions of the current model, the results obtained can be applied clinically to select properly both implant thread depth and body shape design for a foreseeable success of implant therapy.

Scopus Crossref
View Publication
Publication Date
Tue Jun 01 2021
Journal Name
Journal Of Engineering
Experimental Investigation of a Single Basin -Single Slope Solar Still Coupled with Evacuated Tube Solar Collector
...Show More Authors

This work is an experimental investigation for single basin-single slope solar still coupled with an evacuated tube solar collector. The work is carried out under the climatic conditions of Baghdad city (33.2456º North and East latitude, 44.3337º longitude) through certain days of the months of the year 2019 to study the impact of using evacuated tube solar collector on the daily productivity and efficiency under the outdoors climatic conditions. It was found that using the evacuated tube solar collector increase daily productivity from 2.175 kg/  to 2.95 kg/ for 9 hours (35.63 %) for clear days, also an enhancement about 10.97 % in daily efficiency.

View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Jun 03 2019
Journal Name
Rawal Medical Journal
SUPERIOR VERSUS ANTERIOR PLATING OF MIDSHAFT CLAVICLE FRACTURE IN ADULT COMPARATIVE STUDY
...Show More Authors

Clavicle fractures are common injuries in young, active individuals. The majority of the fractures (80% to 85%) occur in the mid-shaft of the bone and account for approximately 2.6% of all fractures. For many years the standard treatment of fracture clavicle was the "figure-of-eight" bandage but several indications for operative fixation, the position of plate fixation for clavicle fracture remains controversial. The aim of this study is to compare between anterio—inferior and anterior-superior plating of mid-shaft displaced clavicle fracture in complications, plate prominence, nonunion, malunion and range of motion. This study is a prospective study conducted in Al-Kindy teaching hospital .A total of 30 patients with fracture mid –sh

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
Brazilian Dental Science
Actual dimensions, design, and fabrication of readymade posterior palatal seal for completely edentulous patients
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu Sep 15 2022
Journal Name
Romanian Neurosurgery
Impact of dome projection on operative steps during clipping of a ruptured pure posteriorly directed posterior communicating artery aneurysms
...Show More Authors

Background: Ruptured posterior communicating artery (PCoA) aneurysms are common; they usually present with subarachnoid haemorrhage (SAH) and oculomotor nerve palsy. The aneurysmal dome projection may influence the safety access and aneurysmal neck clipping. Here, we discuss additional intraoperative steps that may be required to widen the surgical field to ensure safe surgical clipping of a rupture pure posteriorly directed PCoA aneurysm. Case description: A previously healthy 38-year-old male reported sudden severe headache and disturbed level of consciousness with a Glasgow coma scale (GCS) of 13. His initial computed tomography (CT) scan of the head showed SAH in the basal cistern. 3D-constructed CT angiography (CTA) revealed a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jun 01 2015
Journal Name
The European Physical Journal Applied Physics
A carbon nanotubes photoconductive detector for middle and far infrared regions based on porous silicon and a polyamide nylon polymer
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements
...Show More Authors

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician cou

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 11 2023
Journal Name
Applied Sciences
A Preliminary Study and Implementing Algorithm Using Finite State Automaton for Remote Identification of Drones
...Show More Authors

Electronic remote identification (ER-ID) is a new radio frequency (RF) technology that is initiated by the Federal Aviation Authorities (FAA). For security reasons, traffic control, and so on, ER-ID has been applied for drones by the FAA to enable them to transmit their unique identification and location so that unauthorized drones can be identified. The current limitation of the existing ER-ID algorithms is that the application is limited to the Wi-Fi and Bluetooth wireless controllers, which results in a maximum range of 10–20 m for Bluetooth and 50–100 m for Wi-Fi. In this study, a mathematical computing technique based on finite state automaton (FSA) is introduced to expand the range of the ER-ID RF system and reduce the ene

... Show More
View Publication
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-kindy College Medical Journal
Results of Kidney Biopsies among Adult Iraqi Patients in a Single Center
...Show More Authors

Background: Patients requiring renal biopsies have various glomerular diseases according to their demographic characteristics.
Objective: To study types of glomerular disease among adult Iraqi patients in a single center in Baghdad/Iraq
Material and Methods: A total of 120 native kidney biopsies were studied. All biopsies were adequate and were processed for Light Microscopy.
The age range of the study patients was 17-67 years, with a mean of 38.5 years. The mean follow up period was 28 weeks (4-52 weeks)
Indication for biopsy included: Nephrotic syndrome (N=72; 60%), Asymptomatic proteinuria (N=21; 17.5%), acute nephritic presentation (N=17; 14.16%), asymptomatic haematuria (N=10; 8.33%).
Results: Primary glomerulonephrit

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 22 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Finite Elements Analysis Study of Warming Effect on Deboned Force for Embedded NiTinol Wire into Linear Low Density Polyethylene
...Show More Authors

This study presents the debonding propagation in single NiTi wire shape memory alloy into linear low-density polyethylene matrix composite the study of using the pull-out test. The aim of this study is to investigate the pull-out tests to check the interfacial strength of the polymer composite in two cases, with activation NiTinol wire and without activation. In this study, shape memory alloy NiTinol wire 2 mm diameter and linear fully annealed straight shape were used. The study involved experimental and finite element analysis and eventually comparison between them. This pull-out test is considered a substantial test because its results have a relation with behavior of smart composite materials. The pull-out test was carried out by a u

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Advances In Animal And Veterinary Sciences
Community Composition of Parasitic Nematodes of Cyprinion Macrostomum from North and Mid West Regions In Iraq
...Show More Authors

View Publication
Scopus Crossref