Preferred Language
Articles
/
huaVLZ4BmraWrQ4dbF97
Biomechanical finite element analysis of a single implant threaded in anterior and posterior regions of maxilla bone
...Show More Authors

Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two different regions of maxilla bone (anterior (type III bone) and posterior (type IV bone)). A 3D-CAD geometry of implant-maxilla bone was created through importing digitally visualized CT skull images of a human adult, and then converted into a workable solid body through using a collection of engineering software. Tapered and cylindrical implant models with three different implant V-shaped thread depths (0.25 mm, 0.35 mm, 0.45 mm) were threaded into maxilla bone to investigate the design parameters effect on the final stress status. The proposed implant was of commercial dimensions of 10 mm length and 4 mm in diameter. A vertical static load of 250N was directly applied to the center of the suprastructure of the implant for each model. Results: Evaluations were performed for stress distribution patterns and maximum equivalent Von Mises (EQV) stresses for implants in two regions of maxilla bone under 250N vertical static loading. The obtained results throughout this work showed that, for all models, the highest stresses were located at the crestal cortical bone around the implant neck. The von-Mises stress distribution patterns at different models were similar and higher peak von-Mises stresses of cortical bone were seen in tapered implant body compared to cylinder body in all models. Conclusions: Within the restrictions of the current model, the results obtained can be applied clinically to select properly both implant thread depth and body shape design for a foreseeable success of implant therapy.

Scopus Crossref
View Publication
Publication Date
Sun Mar 06 2016
Journal Name
Baghdad Science Journal
Prevalence of Urinary Schistosomiasis in Al-Rusafah Regions of Baghdad governarate
...Show More Authors

Urinary Schistosomiasis is one of important diseases that cause irritation and damage of urinary tract and other systems and tissues and can not be expected by doctors when diagnosing urinary tract diseases.The current study is conducted to investigate the prevalence of schistosomiasisin Baghdad / Al-Rusafa. 191urine samples were collected fromresidents ofsome areas of Al-Rusafain Baghdad governarate (Almashtal, Albaladyat, Alameen, Baghdad aljadida and Alnahrawan) for the period from March until the end of September 2010.The samples were examined by the precipitation and examination of micro hematuria by reagent strips. The total infection percentage was 9.42% (18/191) and was significantly higher in males compared tofemales12.64% (11/87)

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Apr 30 2022
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
The effect of biomechanical feedback on the accuracy of the long serve in badminton
...Show More Authors

The primary aim of the study was to find out the values of some biomechanical variables for the long serve skill in badminton and to identify the effect of biomechanical feedback on the performance of long serve. The present study had a single group, pre-post experimental study design. The research community was determined by the intentional method of one group with a pre-and post-test. The players of the Assyrian badminton club constituted the research community. A total of 12 players were present in the research community. The badminton players falling within the age group of 15-17 years for the season 2020-2021 were recruited as the participants for the study. A total of five players were selected as the participant

... Show More
View Publication
Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Journal Of Taibah University Medical Sciences
Histological evaluation of the effects of bone morphogenetic protein 9 and angiopoietin 1 on bone healing
...Show More Authors

View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jul 05 2025
Journal Name
Annals Of Applied Sport Science
Motor Response Time and Biomechanical Factors in Stationary Handball Shooting Accuracy Among University Players
...Show More Authors

Background. Handball is a team sport that demands quick reflexes and precise motor skills, particularly in shooting. Players' ability to shoot accurately and swiftly while stationary makes upper limb reaction time crucial for success. Objectives. The research objective is to study the relationship between the motor time of the muscles of the arms and the index of accuracy of shooting from constancy in fourth-stage students in handball. Methods. The researchers used the descriptive method because it is one of the methods used in the research on a sample of students of the fourth stage of the college of Physical Education and Sports Sciences, where the sample consisted of 29 male students from the community of origin, 43 students. Results. Th

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Bacteriological Findings within Internal Implant Hole Following Flapless Implant Placement
...Show More Authors

Back ground: Microbial penetration inside the implant's internal hole creates a bacterial reservoir that is related with an area of inflamed connective tissue opposite the fixture-abutment junction and this can affect the health of the peri-implant tissue. Aims of the study: Evaluate the types aerobic and anaerobic bacterial count-percentage and difference between Aerobic and Anaerobic microflora in the implant screw hole three months after implant placement. Monitor the periodontal health status of all patients, throughout the study. Material and methods: Study methodology; Eight partially edentulous patients received 20 dental implants and these implants done with flapless surgical procedure. All patients examined clinically to determined

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jul 01 2018
Journal Name
Journal Of Craniofacial Surgery
Does Mixed Conventional/Piezosurgery Implant Site Preparation Affect Implant Stability?
...Show More Authors

The aim of this study was to compare the effect of conventional implant site preparation technique and a combination of conventional/piezosurgery preparation on implant stability measured at different time intervals, insertion torque, and preparation time. A randomized controlled study was designed, it included 26 patients who received 54 dental implants randomly assigned to 2 groups; in the control group, implants were installed after conventional preparation with drills whereas the study group received implants after mixed conventional/piezosurgery preparation. The outcome variables included: implant stability measured immediately after implant insertion, at 8 weeks and 16 weeks postoperatively, insertion torque and preparation time. All

... Show More
View Publication
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Thu Mar 22 2018
Journal Name
Journal Of Biodiversity And Environmental Sciences
Survey and taxonomical study of ants that collected from indoor in different regions of Iraq
...Show More Authors

Publication Date
Sun Sep 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Dynamics of a single Condensing Two-Phase Bubble
...Show More Authors

The dynamics of a single condensing two-phase bubble of two different dispersed-continuous systems were studied. The systems were, CCl4 - water and CCl4 - 100% glycerol. Cinephotography was used to determine the change in height, diameter and time. These results were used to determine the experimental rise velocity of the bubble, which was compared with a theoretical one based on some equations used. It was found that the velocity of the first system remained almost constant, while it decreased gradually for the second system.

View Publication Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Al-kindy College Medical Journal
Is the Clinical Diagnosis of Cutaneous Leishmaniasis Justified in Endemic Regions?
...Show More Authors

Leishmaniasis is a transmissible infection brought about by an obligatory intracellular protozoan from the genus Leishmania.  It occurs worldwide in tropical and subtropical regions and can be burdensome in resource-constrained countries. The infection ranges in severity from mild cutaneous lesions to more severe and sometimes life-threatening visceral and distorting mucocutaneous sicknesses. Importantly, cutaneous leishmaniasis (CL) is prevalent in the Middle East with a pooled prevalence of 12%. It imposes a significant health and socioeconomic burden

View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Oct 23 2025
Journal Name
Baghdad Science Journal
Continuous Flow Injection-Turbidimetric Analysis for Determination of Cobalt (II) Ion in Alloys Using a Microcell with Irradiation Sources at 0–180° Using a Single Solar Cell as a Detector
...Show More Authors

A cost-effective and efficient detector was created to conduct thorough turbidimetric measurements by reaction of Co (II) ion with calcium ferro cyanide to form bright green particulate, using the method of continuous flow injection analysis, the use of NAG-5SX1-1D-SSP Analyzer in determining cobalt (II) ion in a test for the validity of the new design. The NAG-5SX1-1D-SSP Analyzer is composed of five irradiation sources of white snow leds having the diameter of 10 mm with one solar cell of 55 mm length, 13.5 mm width. Using a selector switch to select the optimum voltage to be used which was 2.7 VDC. Under conditions of optimization, cobalt (II) ion was determined at 0.005–20 mmol. L–1(n = 23) while linearity dynamic range 0.005–7 mm

... Show More
View Publication
Scopus (2)
Crossref (5)
Scopus Clarivate Crossref