Preferred Language
Articles
/
jbcd-2383
Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements
...Show More Authors

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician could precisely predict the primary stability of an implant on insertion with different surgical procedures using his own tactile perception. Materials and methods: A total of (60) Iraqi adult patients, (28) males and (32) females, age ranged (22-66) years old were enrolled in this clinical prospective study. The maximum torque value recorded on implant insertion using calibrated manual torque ratchet adopting three categories: low (10 to 30 N/cm), medium (30 to 50 N/cm), and high insertion torque (50 to 70 N/cm). The oral surgeon was asked to indicate the perceived ISQs values according to his perception then Implant stability quotient were measured by Osstell ™. Bone density (type) was determined according to subjective bone resistance encountered while drilling as proposed by Lekohlm and Zarb. Results: A total of 160 implants were inserted. The mean peak IT value was 49 ± 2.61N/cm. The mean ISQ value was 71.7 ± 8.86. Statistical analysis show a significant correlation between ISQ values and PIT values (P<0.001) , between IT values and bone types and between perceived primary stability and actual primary stability (P<0.001) . Conclusions:The corresponding significant correlations between insertion torque, and ISQ values may help clinicians to predict primary stability on implant insertion, that may be associated with implant survival and success rates. A moderate reliability (correlation) between perceived ISQ values and those measured using RF analyzer(Ossttel device).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of Bolton’s Ratios in a Sample of Iraqi and Egyptian Populations
...Show More Authors

Background: The objective of this study was to investigate the possibility of standardizing the Bolton ratio analysis as a diagnostic measure for both Iraqi and Egyptian orthodontic populations within three Angle' classification groups. Materials and methods: Two hundred forty pretreatment study casts (one hundred twenty of each population) were included in this study and divided into three Angle' classification groups. The mesiodistal crown diameters of all teeth were measured for computing the anterior and total Bolton ratios. Analysis of variance was performed to compare the mean ratios of Bolton analysis as a function of the Angle classification.HSD test was used to specify the classes of malocclusion that have significant differences.

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect Of Treatment Protocol and Implant Dimensions on Primary Stability Utilizing Resonance Frequency Analysis
...Show More Authors

ABSTRACT Background: According to Branemark’s protocol, the waiting period between tooth extraction and implant placement is 6–8 months; this is the late placement technique. Achieving and maintaining implant stability are prerequisites for a dental implant to be successful. Resonance Frequency Analysis (RFA) is a noninvasive diagnostic method that measures implant stability. The aim of this study was to investigate the influence of treatment protocol and implant dimensions on primary implant stability utilizing RFA. Materials and methods: This study included 63 Iraqi patients (37 male, 26 female; ranging 22-66 years). According to treatment protocol, the sample was divided into 2 groups; A (delayed) & B (immediate). Dental im

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
The relationship of implant stability quotient and insertion torque in dental implant stability
...Show More Authors

Background: The insertion torque (IT) values and implant stability quotient (ISQ) values are the measurements most used to assess primary implant stability. This study aimed to assess the relationship between ISQ values and IT. Materials and methods: This study included 24 patients with a mean (SD) age of 47.9 (13.64) years (range 25-75 years). The patients received 42 dental implants (DI), 33 in the mandible and 9 in the maxilla. The DI were installed using the motorized method with 35 Ncm torque, When DI could not be inserted to the requisite depth by the motorized method, a hand ratchet was used and the IT was recorded as ˃ 35 Ncm. Implant stability was measured utilizing Osstell® ISQ. The secondary stability was measured after 16

... Show More
View Publication Preview PDF
Crossref (2)
Scopus Crossref
Publication Date
Thu Dec 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of dental implant stability during healing period and determination of the factors that affect implant stability by means of resonance frequency analysis(Clinical study)
...Show More Authors

Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Immunohistochemical expression of P53, as a marker of apoptosis in Hodgkin’s and Non Hodgkin’s lymphoma of the head and neck region
...Show More Authors

Background: Malignant lymphomas represent about 5% of all malignancy of the head and neck region which can involve lymph nodes as well as soft tissue and bone of the maxillofacial region. Apoptosis is considered a vital component of various processes including normal cell turnover, proper development and functioning of the immune system. Inappropriate apoptosis is a factor in many human conditions including neurodegenerative diseases, ischemic damage, autoimmune disorders and many types of cancer. Expression of p53 Proteins in Hodgkin׳s and Non Hodgkin׳s lymphomas suggested that it can help in monitoring of patients and the markers may aid in controlling the progression of lymphoma and detect the degree of aggressiveness of the diseas

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Immunohistochemical expression of MMP9, as a marker of local invasion in Hodgkin’s and Non-Hodgkin’s lymphoma of the head and neck region
...Show More Authors

Background: Malignant lymphoma is the generic term given to tumors of the lymphoid system and specifically of lymphocytes and their precursor cells, While all lymphomas are malignant neoplasms, there is a wide spectrum of clinical behavior, with some following an indolent clinical course and others behaving in an aggressive manner (will causing death in a short time frame if left untreated). The metastatic process involves intravasation and extravasation of tumor cells, followed by reimplantation of tumor cells, formation of a new tumor stoma, Degradation of the extracellular matrix and components of the basement membrane by proteases facilitates the detachment of tumor cells, their crossing of tissue boundaries, and invasion into adjacent

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The reliability of insertion torque as an indicator for primary stability in immediate dental implant: A prospective clinical study
...Show More Authors

Background: The primary stability of the dental implant is a crucial factor determining the ability to initiate temporary implant-supported prosthesis and for subsequent successful osseointegration, especially in the maxillary non-molar sites. This study assessed the reliability of the insertion torque of dental implants by relating it to the implant stability quotient values measured by the Osstell device. Material and methods: This study included healthy, non-smoker patients with no history of diabetes or other metabolic, or debilitating diseases that may affect bone healing, having non-restorable fractured teeth and retained roots in the maxillary non-molar sites. Primary dental implant stability was evaluated using a torque ratc

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Reliability of the multipeg™ transducer in measuring dental implant stability by using a resonance frequency analysis device (Osstell®): An observational clinical study
...Show More Authors

Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Dec 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Immunohistochemical expression of MMP1 and TIMP1 as markers of migration in Hodgkin’s and non-Hodgkin’s lymphoma of the head and neck region (A comparative study)
...Show More Authors

Background: Malignant lymphoma is a term that describes primary tumors of the lymphoreticular system, almost all of which arise from lymphocytes.MMP-1 is the most ubiquitously expressed interstitial collagenase, a subfamily of MMPs that cleaves stromal collagens. It is also called collagenase-1.TIMPs which inhibits MMP activity and thereby restrict extracellular matrix breakdown, TIMP-1 is a stromal factor that has a wide spectrum of functions in different tissues. Material and Methods: This study was performed on (68) formalin-fixed, paraffin-embedded blocks, histopathologically diagnosed as lymphoma (head and neck lesions). Immunohistochemical staining of MMP1and TIMP1 was performed on each case of the study sample. Results: The expressio

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of The College Of Languages (jcl)
A comparison between Objective and subjective tests
...Show More Authors

This paper aims at presenting a comparison between objective and subjective tests . This paper attemptsto shed light on these two aspects of tests and make do a compression by using suitable techniques for objective and subjective tests .

     The paper compares between the two techniques used by the objective and subjective tests respectively, the time and efforts required by each type, the extent to which each type can be reliable, and the skills each type is suitable to measure.

     The paper shows that objective tests, on the contrary of the subjective ones, encourages guess> Objective tests are used to test specific areas of langua

... Show More
View Publication Preview PDF