Preferred Language
Articles
/
hoaPrYYBIXToZYALfaOq
Strength compensation of deep beams with large web openings using carbon fiber–reinforced polymer sheets
...Show More Authors

This article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while the other eight deep beams were with openings in shear spans and with carbon fiber–reinforced polymer sheet strengthening around opening zones. The opening size was adopted to be 200 × 200 mm dimensions in eight deep beams, while it was considered to be 230 × 230 mm dimensions in the other eight specimens. In eight specimens the opening was located at the center of the shear span, while in the other eight beams the opening was attached to the interior edge of the shear span. Carbon fiber–reinforced polymer sheets were installed around openings to compensate for the cutout area of concrete. Results gained from the experimental test showed that the creation of openings in shear spans affect the load-carrying capacity, where the reduction of the failure load for specimens with the opening but without strengthening may attain 66% compared to deep beams without openings. On the other hand, the strengthening by carbon fiber–reinforced polymer sheets for beams with openings increased the failure load by 20%–47% compared with the identical deep beam without strengthening. A significant contribution of carbon fiber–reinforced polymer sheets in restricting the deformability of deep beams was observed.

Scopus Clarivate Crossref
Publication Date
Wed Jun 10 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Plasma Treatment on Shear Bond Strength of High Impact Acrylic Resin Denture Base Lined with Two Types of Soft Lining Materials after Immersion in Distilled Water and Denture Cleanser
...Show More Authors

Background: In dentistry, dentist takes the advantages of soft lining materials due to the viscoelastic properties. The major problem is the adhesion of the soft liner with the denture base material. Materials and Methods: Heat cured of high impact acrylic resin specimens prepared with dimensions 75x13x13mm for shear bond strength test, soft lining material (Refit and Mollosil) with a 3-mm thickness and used to join each two acrylic blocks. Also four specimens with the same previous dimensions utilized for chemical and physical surface analysis. The specimens grouped as control (without plasma) and experiment (with oxygen plasma) treated high impact acrylic specimens. Results: Plasma treatment increased the shear bond strength for both Refi

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 01 2018
Journal Name
European Journal Of Pharmaceutical Sciences
The effect of size and polymer architecture of doxorubicin–poly(ethylene) glycol conjugate nanocarriers on breast duct retention, potency and toxicity
...Show More Authors

View Publication
Scopus (22)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Fri Jun 29 2018
Journal Name
Journal Of Engineering
Experimental Investigation of Short Square Normal and Hybrid Fiber Reactive Powder Concrete Columns Subjected to Chloride Solution Attack
...Show More Authors

In this research, the structural behavior of reinforced concrete columns made of normal and hybrid reactive powder concrete (hybrid by steel and polypropylene fibers) subjected to chloride salts with concentration was 8341.6 mg/l. The study consists of two parts, the first one is experimental study and the second one is theoretical analysis.  Three main variables were adopted in the experimental program; concrete type, curing type and loading arrangement. Twenty (120x120x1200) mm columns were cast and tested depending on these variables. The samples were reinforced using two different bars; Ø8 for ties and Ø12 with minimum longitudinal reinforcement (0.01Ag). The specimens were divided into two main groups based o

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 01 2019
Journal Name
Sensors And Actuators B: Chemical
Fabrication and Characterizations of a Novel Etched-tapered Single Mode Optical Fiber Ammonia Sensors Integrating PANI/GNF Nanocomposite
...Show More Authors

View Publication
Scopus (41)
Crossref (47)
Scopus Clarivate Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Jacc: Cardiovascular Interventions
CRT-100.98 International Registry of Cardiovascular Diseases in Women (IROCW): Assessing the Feasibility of Large Data Registry in the Absence of Funding and Electronic Database – Initial Data From Iraq
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Wed Jun 10 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of cavity design for cusp coverage on fracture strength of weakened maxillary first premolars using two esthetic restorative systems (CAD/CAM hybrid ceramic and nanohybrid composite) (An in vitro study)
...Show More Authors

Background: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 30 2023
Journal Name
Baghdad Science Journal
Deep Learning-based Predictive Model of mRNA Vaccine Deterioration: An Analysis of the Stanford COVID-19 mRNA Vaccine Dataset
...Show More Authors

The emergence of SARS-CoV-2, the virus responsible for the COVID-19 pandemic, has resulted in a global health crisis leading to widespread illness, death, and daily life disruptions. Having a vaccine for COVID-19 is crucial to controlling the spread of the virus which will help to end the pandemic and restore normalcy to society. Messenger RNA (mRNA) molecules vaccine has led the way as the swift vaccine candidate for COVID-19, but it faces key probable restrictions including spontaneous deterioration. To address mRNA degradation issues, Stanford University academics and the Eterna community sponsored a Kaggle competition.This study aims to build a deep learning (DL) model which will predict deterioration rates at each base of the mRNA

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (3)
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Al-nahrain Journal Of Science
The Efficiency of Titanium-Graphite Electrode Cells in the Presence of Ionic Liquids and Deep Eutectic Solvents as Electrolytes
...Show More Authors

Prior to the start of production, several factors must be considered, including the price, effectiveness, and environmental friendliness of batteries. Ionic liquids and deep eutectic solvents have shown significant success when employed as electrolytes with Titanium-graphite cells, especially when combined with additives that enhance their conductivity by reducing the high viscosity of these liquids. Evaluating the discharge voltage of the AlCl3-chloroacetamide IL with DCM as an additive revealed a voltage of 1.16V and an internal resistance of 11 Ohm. These electrochemical cells exhibited an intriguing response. Otherwise, when utilizing CaCl2.2H2O:

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Nov 01 2025
Journal Name
Journal Of Education And Health Promotion
Effect of deep-breathing exercise training on reducing stress among maintenance hemodialysis patients: Quasi-experimental randomized trial study
...Show More Authors
BACKGROUND:

Dialysis is a stressful process and follows various psychological and social problems, which can lead to psychological disturbances. Patients on dialysis experience psychological distress, and the reduction of stress in patients provides psychological resources to cope with their physical condition. The study aimed to evaluate the effect of deep-breathing exercise training on the level of stress among maintenance hemodialysis patients.

MATERIALS AND METHODS:

This study is a randomized

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Feb 06 2023
Journal Name
3c Tecnología_glosas De Innovación Aplicadas A La Pyme
Bond Strength Of Acrylic Soft Liner To Nd:Yag Laser-Treated Thermoplastic Acrylic Denture Base Material
...Show More Authors

Aim of the study: Using surface roughness and tensile bond strength tests, the objective of this investigation was to ascertain the impact of laser surface modification on the binding strength of injectable thermoplastic acrylic denture base material to acrylic-based soft-liner material. Materials and methods: Acrylic base soft liner material was bonded to injectable thermoplastic acrylic resin (Deflex). Forty specimens were created (20 disc, 20 dumbbells) 10 of each specimen type as control specimens, and 10 were treated with nano pulse Nd: YAG laser. The data were analyzed using the Kruskal-Wallis test and unpaired t-test (a=.05) and the roughness test was performed utilizing a double column universal test machine. Results: Compar

... Show More
View Publication
Clarivate Crossref