A novel analytical method is developed for the determination of azithromycin. The method utilizes continuous flow injection analysis to enhance the chemiluminescence system of luminol, H2O2, and Cr(III). The method demonstrated a linear dynamic range of 0.001–100 mmol L-1 with a high correlation coefficient (r) of 0.9978, and 0.001–150 mmol L-1 with a correlation coefficient (r) of 0.9769 for the chemiluminescence emission versus azithromycin concentration. The limit of detection (L.O.D.) of the method was found to be 18.725 ng.50 µL−1 based on the stepwise dilution method for the lowest concentration within the linear dynamic range of the calibration graph. The relative standard deviation (R.S.D. %) for n = 6 was less than 1.2% for azithromycin concentrations of 10 mmol L-1 and 70 mmol L-1. The developed method was successfully applied for the determination of azithromycin in three pharmaceutical drugs. An analysis of variance (ANOVA) test revealed no significant difference between the reference method and the developed method.
A simple, sensitive and accurate spectrophotometric method has been developed for the determination of salbutamol sulphate (SAB) and isoxsuprine hydrochloride (ISX) in pure and pharmaceutical dosage. The method involved oxidation of (SAB) and (ISX) with a known excess of N-bromosuccinamid in acidic medium, and subsequent occupation of unreacted oxidant in decolorization of Evans blue dye (EB). This, in the presence of SAB or ISX was rectilinear over the ranges 1.0-12.0, 1.0-11.0 µg/mL, with molar absorptivity 4.21×104 and 2.58×104 l.mol-1.cm-1 respectively. The developed method had been successfully applied for the determination of the studied drugs in their pharmaceutical dosage resulting i
... Show MoreA rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium is studied. The method is based on the interaction of chromium with indigo carmine dye in acidic medium and the presence of oxalates as a catalyst for interaction, and after studying the absorption spectrum of the solution resulting observed decrease in the intensity of the absorption. As happened (Bleaching) for color dye, this palace and directly proportional to the chromium (VI) amount was measured intensity of the absorption versus solution was figurehead at a wavelength of 610 nm. A plot of absorbance with chromium (VI) concentration gives a straight line indicating that Beer’s law has been obeyed over the range of 0.5
... Show MoreStable isotope (?18O, ?D) values were determined along with the chemical compositions at 10 different locations along the Tigris river between Baghdad-Ammara cities of Iraq. The physico-chemical parameters and isotopic data were measured. The sampling site represents 34 % of total Tigris river in the republic of Iraq. The systematically increased in values of stable isotope as move from the downstream of the river and the most significantly appears at Kut lake. This increase occurs as a result of several factors, viz. (a) evaporation occurs low water level in the river and its tributaries, and (b) return flow water to the river from irrigation water in groundwater systems. The change in ion distribution and in the isotopic values related di
... Show MoreSimple, sensitive and accurate two methods were described for the determination of terazosin. The spectrophotometric method (A) is based on measuring the spectral absorption of the ion-pair complex formed between terazosin with eosin Y in the acetate buffer medium pH 3 at 545 nm. Method (B) is based on the quantitative quenching effect of terazosin on the native fluorescence of Eosin Y at the pH 3. The quenching of the fluorescence of Eosin Y was measured at 556 nm after excitation at 345 nm. The two methods obeyed Beer’s law over the concentration ranges of 0.1-8 and 0.05-7 µg/mL for method A and B respectively. Both methods succeeded in the determination of terazosin in its tablets
In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement. The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.
A study of Zooplankton community has been carried out at four selected sites on Dukan Lake. Samples of water and zooplankton were collected monthly for the period from July 2015 to February 2016. Some physical and chemical properties of water were studied and the results showed that the air temperature were ranged from 0 to 36.16 °C, water temperature ranged from 2.83 to 34.66 °C, hydrogen ion concentration of studied sites were found to lie in alkaline side, it was ranged between 6.87 to 8.57, electrical conductivity ranged from 190.79 to 850.08 µs.cm¹, turbidity ranged from 0.9-7.7 NTU, and dissolved oxygen from 3.3 to 6.8 mg.l-¹ while BOD5 were ranged from 0.53 to 34.66 mg.l-¹. Concerning to the zooplankton, 37 species were ident
... Show MoreAbstract
Binary logistic regression model used in data classification and it is the strongest most flexible tool in study cases variable response binary when compared to linear regression. In this research, some classic methods were used to estimate parameters binary logistic regression model, included the maximum likelihood method, minimum chi-square method, weighted least squares, with bayes estimation , to choose the best method of estimation by default values to estimate parameters according two different models of general linear regression models ,and different s
... Show More