An experimental program was conducted to determine the residual of composite Steel Beams-Reinforced Concrete (SB-RC) deck floors fabricated from a rolled steel beam topped with a reinforced concrete slab, exposed to high temperatures (fire flame) of 300, 500, and 700ºC for 1 hour, and then allowed to cool down by leaving them in the lab condition to return to the ambient temperature. The burning results showed that, by exposing them to a fire flame of up to 300ºC, no serious permanent deflection occurred. It was also noticed that the specimen recovered 93% of 19.2 mm of the deflection caused by burning. The recovered deflection of burned composite SB-RC deck floor at 500ºC was 40% of 77.9 mm of the deflection caused by burning with a residual deflection of 46.4 mm. The greatest deterioration occurred when exposed to 700ºC, at this temperature, a higher unrecoverable permanent deflection was recorded (160.3 mm) of the maximum measured burning deflection (173.8mm), indicating that the percent recovered deflection was 8%. Then, all composite SB-RC deck floors were loaded until failure to determine the percent decrease in their ultimate capacity. The results were compared with the behavior of composite SB-RC deck floor without burning (reference specimen).
This study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p
... Show MoreThe study aimed to identify the importance of time in the Faculties of Physical Education and Sports Sciences at the University of Baghdad, as well as to identify the relationship between time management and the level of staff functional performance. The research population consisted of the staff members who work in the Faculties of Physical Education and Sports Sciences for Girls in Al-Jadriya for the academic year 2017-2018. A random sample of 50 staff members from each faculty were selected, that is the total number was (100) staff members. The researchers identified the concept of time management and functional performance, after that a questionnaire consisting of (39) statements and (6) parts presented to a specialized group of experts
... Show MoreThe study was conducted in the poultry field of the Department of Animal Production/ College of Agricultural Engineering Sciences/ University of Baghdad/ Abu Ghraib, for the period from 28/04/2022 to 08/06/2022 to demonstrate the effect of adding a mixture of Lion’s mane Hericium erinaceus and Reishi Mushroom Ganoderma lucidum to broiler's diets on productive performance, 120 one day old Ross 308 breed broiler chicks were used in the experiment, with (10 birds / replicate) with an average starting weight of 49.95 g. The experiment treatments were as follows:(T1) basic diet control treatment free of any addition. (T2) the basic diet with the addition of 0.5 g/kg fodder of Lion's Mane mushroom with 0.5 g/kg fodder of the Reishi Mus
... Show MoreThe study aimed to identify the importance of time in the Faculties of Physical Education and Sports Sciences atthe University of Baghdad, as well as to identify the relationship between time management and the level of staff functionalperformance. The research population consisted of the staff members who work in the Faculties of Physical Education andSports Sciences for Girls in Al-Jadriya for the academic year 2017-2018. A random sample of 50 staff members from eachfaculty were selected, that is the total number was (100) staff members. The researchers identified the concept of timemanagement and functional performance, after that a questionnaire consisting of (39) statements and (6) parts presented to aspecialized group of experts. The
... Show MoreThe banking sector has a significant impact on the economic growth of the country, and the importance of this sector must assess its financial performance from time to time, to measure the situation related to money for each bank and how to put the supervision of the efficiency of the full. The research aims at evaluating the financial performance according to the elements of the CAMELS model, which including capital adequacy, asset quality, management efficiency, profitability, liquidity, and market risk sensitivity. The research included the study of Al-Mansour Investment Bank during the period from 2014 to 2018. The base capital ratio was used to total assets to measure capital adequacy The proportion of investments to total a
... Show MoreIn a hybrid cooling solar thermal systems , a solar collector is used to convert solar energy into heat energy in order to super heat the refrigerant leaving the compressor, and this process helps in the transformation of refrigerant state from gaseous state to the liquid state in upper two-thirds of the condenser instead of the lower two-thirds such as in the traditional air-conditioning systems and this will reduce the energy needed to run the process of cooling .In this research two systems with a capacity of 2 tons each were used, a hybrid air-conditioning system with an evacuated tubes solar collector and a traditional air-conditioning system . The refrigerant of each type was R22.The comparison was in the amou
... Show MoreThis paper develops a nonlinear transient three-dimensional heat transfer finite element model and a rate independent three-dimensional deformation model, developed for the CO2 laser welding simulations in Al-6061-T6 alloy. Simulations are performed using an indirect coupled thermal-structural method for the process of welding. Temperature-dependent thermal properties of Al-6061-T6, effect of latent heat of fusion, and the convective and radiative boundary conditions are included in the model. The heat input to the model is assumed to be a Gaussian heat source. The finite element code ANSYS12, along with a few FORTRAN subroutines, are employed to obtain the numerical results. The benefit of the proposed methodology is that it
... Show MoreWhen a vehicle is left parked in the sun for an extended period, the gathered heat causes damage to several interiors within the cabin and causes discomfort for people and animals left inside the car. In the present work, the effect of the orientation of a parked white minibus on temperature distribution and cooling load calculation is studied experimentally in an open environment. Two different cases were studied facing south and facing east. For several hours, the temperature inside the car cabin had been monitored and measured at five separate locations. The cooling load calculations are carried out based on the experimental measurements. The results show that the overheating of parked cars always happens as a result
... Show More