Preferred Language
Articles
/
fhiLZ5UBVTCNdQwCbS0l
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
...Show More Authors

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05).Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed May 17 2023
Journal Name
College Of Islamic Sciences
Time in (what and whatever) conditionals
...Show More Authors

This is a research in which I studied the opinions of Arab scholars, in their studies
For (what) and (whatever) the two conditionals and their indication of time, and its name
B (time in (what) and (whatever) the two conditions), and I mentioned their opinions in it
This issue was discussed and discussed, and in this study it relied on the sources of the Arabic language.
Especially the books of grammar, interpretation, and the opinions of the scholars of the principles of jurisprudence are mentioned,
I also mentioned the opinion of the scholars of jurisprudence, and how they likened (whatever) to (everything).
In its indication of repetition, and as long as it indicates repetition, it indicates
time Because repetitio

... Show More
View Publication Preview PDF
Publication Date
Mon May 15 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Developing a Real Time Method for the Arabic Heterogonous DBMS Transformation
...Show More Authors

   A common problem facing many Application models is to extract and combine information from multiple, heterogeneous sources and to derive information of a new quality or abstraction level. New approaches for managing consistency, uncertainty or quality of Arabic data and enabling e-client analysis of distributed, heterogeneous sources are still required. This paper presents a new method by combining two algorithms (the partitioning and Grouping) that will be used to transform information in a real time heterogeneous Arabic database environment

View Publication Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Physics: Conference Series
A Multilevel Approach for Stability Conditions in Fractional Time Diffusion Problems
...Show More Authors
Abstract<p>The Caputo definition of fractional derivatives introduces solution to the difficulties appears in the numerical treatment of differential equations due its consistency in differentiating constant functions. In the same time the memory and hereditary behaviors of the time fractional order derivatives (TFODE) still common in all definitions of fractional derivatives. The use of properties of companion matrices appears in reformulating multilevel schemes as generalized two level schemes is employed with the Gerschgorin disc theorems to prove stability condition. Caputo fractional derivatives with finite difference representations is considered. Moreover the effect of using the inverse operator which tr</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jan 01 2006
Journal Name
Journal Of Engineering
SELF ORGANIZING FUZZY CONTROLLER FOR A NON-LINEAR TIME VARYING SYSTEM
...Show More Authors

This paper proposes a self organizing fuzzy controller as an enhancement level of the fuzzy controller. The adjustment mechanism provides explicit adaptation to tune and update the position of the output membership functions of the fuzzy controller. Simulation results show that this controller is capable of controlling a non-linear time varying system so that the performance of the system improves so as to reach the desired state in a less number of samples.

Publication Date
Fri Jan 01 2016
Journal Name
Applied Numerical Mathematics
Multiple time-dependent coefficient identification thermal problems with a free boundary
...Show More Authors

View Publication
Scopus (27)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Iaes International Journal Of Robotics And Automation
Implementation of a complex fractional order proportional-integral-derivative controller for a first order plus dead time system
...Show More Authors

This paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi

... Show More
Publication Date
Fri Apr 12 2019
Journal Name
Journal Of Economics And Administrative Sciences
Imported inflation ... concept, transmission channels, effects, and processors Iraq Case study for the period (1990-2015)
...Show More Authors

This research aims to explain the effect of the imported inflation (which moves through the raise of global prices to Iraqi economy) over local prices, besides, the recognition the most important channels of imported inflation moving, its causes, effects, ways and policies that reduce the negative effects. To achieve the research aim, the deductive approach was adopted through using descriptive method to describe and determine phenomenon. The most important conclusion is that the research found out that there are two channels to transmission imported inflation in world. The first channel is the direct channel (prices) and the second channel is the indirect (income). The most important recommendation is to create sovereign fund (O

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research &amp; Development
Predictive Value of Spectral Waveform Indices; Intimal Medial Thickness and Lumen Diameter of Carotid Artery in Iraqi Diabetic and Hypertensive Patients
...Show More Authors

Background: Diabetes and hypertension are related to cardiovascular risk factors and are possible to detect development of atherosclerosis in cardiovascular system, were can predict their effect and measurement by ultrasound and Doppler study. These risk factors included increased intima-media thickness, resistive index (RI) and pulsatility index (PI) of the right common carotid arteries. Method: We studied 20 patients with diabetes and hypertension, and 20 patients with diabetes only, were examine right carotid arteries for these two groups. In this sample we studied the Lumen diameter of the Rt. carotid arteries, Intima – media thickness (IMT), peak systolic velocity, end diastolic velocity, and Pulsatility index, Resistance index were

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jan 05 2009
Journal Name
J. Duhok Univ
The role of red pigment produced by Serratia marcescens as antibacterial and plasmid curing agent
...Show More Authors

Preview PDF
Publication Date
Mon Sep 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Treatment of Wastewater of Alcohol Factory by Filtration as Primary Treatment
...Show More Authors

View Publication Preview PDF