Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05).Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running
In this study, aromatic polyamide reverse osmosis membranes were used to remove zinc ions from electroplating wastewater. Influence of different operating conditions such as time, zinc concentration and pressure on reverse osmosis process efficiency was studied. The experimental results showed, concentration of zinc in permeate increase with increases of time from 0 to 70 min, and flux of water through membrane decline with time. While, the concentrations of zinc in permeate increase with the increase in feed zinc concentration (10–300 mg/l), flux decrease with the increment of feed concentration. The raise of pressure from 1 to 4 bar, the zinc concentration decreases and the flux increase. The highest recovery percentage was found is 54.
... Show MoreVarious nutritional solutions given to patients contain amino acids. Possible interference of this supplementation with selected aminoglycoside antiboiotics, namely gentamycin and streptomycin was evaluated in vitro. In minimal medium, E.coli was inhibited by gentamycin and by streptomycin. Circumvention of this inhibition was obtained with a mixture of 20 amino acids in the medium. Deletion of amino acids revealved that circumvention. specific amino acids were required for such Deletion of the aromatic amino acids or cysteine abolished the protection against gentamycin and streptomycin, while the deletion of the branched chain amino acids abolished the protection against streptomycin only. Thereonine, on the other hand, appears to be essen
... Show MoreIn this study, aromatic polyamide reverse osmosis membranes were used to remove zinc ions from electroplating wastewater. Influence of different operating conditions such as time, zinc concentration and pressure on reverse osmosis process efficiency was studied. The experimental results showed, concentration of zinc in permeate increase with increases of time from 0 to 70 min, and flux of water through membrane decline with time. While, the concentrations of zinc in permeate increase with the increase in feed zinc concentration (10–300 mg/l), flux decrease with the increment of feed concentration. The raise of pressure from 1 to 4 bar, the zinc concentration decreases and the flux increase. The highest recovery percentage was fou
... Show MoreA simplified theoretical comparison of the hydrogen chloride (HCl) and hydrogen fluoride (HF) chemical lasers is presented by using computer program. The program is able to predict quantitative variations of the laser characteristics as a function of rotational and vibrational quantum number. Lasing is assumed to occur in a Fabry-Perot cavity on vibration-rotation transitions between two vibrational levels of hypothetical diatomic molecule. This study include a comprehensive parametric analysis that indicates that the large rotational constant of HF laser in comparison with HCl laser makes it relatively easy to satisfy the partial inversion criterion. The results of this computer program proved their credibility when compared with th
... Show MoreIn this research two algorithms are applied, the first is Fuzzy C Means (FCM) algorithm and the second is hard K means (HKM) algorithm to know which of them is better than the others these two algorithms are applied on a set of data collected from the Ministry of Planning on the water turbidity of five areas in Baghdad to know which of these areas are less turbid in clear water to see which months during the year are less turbid in clear water in the specified area.
Nanoparticles generation by laser ablation of a solid target in a liquid environment is an easy method. Cadmium Telluride (CdTe) colloidal nanoparticles have been synthesized by laser ablation Nd:YAG with wavelengths of 1064nm and double frequency at 532 nm, number of pulses 50 pulses, with pulse energy= 620mJ, 700mJ of a solid target CdTe is immersed in double distilled deionized water (DDIW) and in methanol liquid. Influences of the laser energy and different solutions on the formation and optical characterization of the CdTe nanoparticles have been studied using atomic force microscope (AFM) and the UV-Vis absorption. As a results, it leads to the absorbance in UV-Vis spectra of samples prepared in water at laser wavelength of 532nm i
... Show MoreA solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS
... Show MoreSlag of aluminum is a residue which results during the melting process of primary and secondary aluminum production. Salt slag of aluminum is hazardous solid waste according to the European Catalogue for Hazardous Wastes. Hence, recovery of aluminum not only saves the environment, but also has advantages of financial and economic returns. In this research, aluminum was recovered and purified from the industrial wastes generated as waste from both of State Company for Electrical and Electronic Industries (Baghdad/AlWaziriya) and General Company for Mechanical Industries (Babylon/-Al-Escandria). It was found that these wastes contain tiny proportions of other elements such as iron, copper, nickel, titanium, lead, and potassium. Wastes were
... Show MoreIsocratic high performance liquid chromatography on reversed phase a (150x 4.6 mm I.D), 5 ?m ?-Bondapak RP-8 column (with acidic mobile phase allow the separation of doxcycycline hydrochloride with low detection limit of 0.2 µg/ml detected by UV set at 226 nm. The method was validated for Doxycycline between 0.156- to 5 µg/ml. The concentration of doxycycline was assessed in two single dose randomized crossover studies with intervals of one week between two period. In sera of 20 adults healthy male volunteers with average age of (42 + 10) year, body weight 48-85 kg, body height of (160-185cm) after a single dose of doxycycline hydrochoride 100 mg in form of capsules were orally administrated for both formulations. The blood sa
... Show More