Background: A review of articles of method in treating compound phalangeal fractures by using mini-external fixator, elaborating the anatomy, mechanics, modalities of treatment, and complications of these types of fractures. Also, it compares between different studies regarding the functional results and final outcome. External fixation of phalangeal fractures is a good method for osteo synthesis in certain situations. The simplicity of the surgical procedure and the minimal disruption of the normal bone architecture also make it appealing. Objectives: Evaluating the functional results of the use of mini-external fixator for the treatment of compound fractures of phalangeal bones of the hand. Method: Our study consists of 15 patients, 12 were male and 3 was female, treated with external fixator for sever open hand fractures at Al-Kindy teaching hospital during the period from June 2011 – June 2013, using 2 K-wires bonded by IV needle cover, or 2 K-wires bonded by bone cement. Results: In comparison between different studies, external fixation offers several advantages. It allows preservation of the bone architecture, union of the fracture, facilitating healing of the disrupted area, and good functional results. External fixation is versatile, adapting to a wide range of clinical situations. This method of fixation provides good stability and adequate control of comminuted fractures, allowing not only anatomic restoration but also early active motion. Conclusion: External fixators are appropriate in cases of open, comminuted, unstable fractures. Other appropriate settings for external fixation include temporal management of fractures and length preservation of a functional digit.
It is believed that Organizations around the world should be prepared for the transition to IPv6 and make sure they have the " know how" to be able to succeed in choosing the right migration to start time. This paper focuses on the transition to IPv6 mechanisms. Also, this paper proposes and tests a deployment of IPv6 prototype within the intranet of the University of Baghdad (BUniv) using virtualization software. Also, it deals with security issues, improvements and extensions of IPv6 network using firewalls, Virtual Private Network ( VPN), Access list ( ACLs). Finally, the performance of the obtainable intrusion detection model is assessed and compared with three approaches.
There are risks and benefits with all medicines and estrogen replacement is no exception. In fact, estrogen replacement is one of the most controversial topics in Endocrinology. Anastatica hierochuntica L. is a popular treatment for the management of female reproductive disorders. The present research highlights the effect of aqueous extract of plant against conjugated estrogen(Premarin) in rabbits. Femal oryciolagus cuniculus rabbits were divided into four groups: the 1 st group, rabbits were orally administered (using a feeding solution )with daily dose(5 mL distilled water)for two months, the 2nd group, the rabbits were treated with conjugated estrogen (50 µg/kg b.w, body weight )for one month. The 3rd group, the rabbits were treated wi
... Show MoreThe increasing availability of computing power in the past two decades has been use to develop new techniques for optimizing solution of estimation problem. Today's computational capacity and the widespread availability of computers have enabled development of new generation of intelligent computing techniques, such as our interest algorithm, this paper presents one of new class of stochastic search algorithm (known as Canonical Genetic' Algorithm ‘CGA’) for optimizing the maximum likelihood function strategy is composed of three main steps: recombination, mutation, and selection. The experimental design is based on simulating the CGA with different values of are compared with those of moment method. Based on MSE value obtained from bot
... Show MoreThe high and low water levels in Tigris River threaten the banks of the river. The study area is located on the main stream of Tigris River at Nu’maniyah City and the length of the considered reach is 5.4 km, especially the region from 400 m upstream Nu’maniyah Bridge and downstream of the bridge up to 1250 mwhich increased the risk ofthe problemthat itheading towardsthe streetand causingdanger tonearbyareas.
The aim of this research is to identify the reason of slope collapse and find proper treatments for erosion problem in the river banks with the least cost. The modeling approach consisted of several steps, the first of which is by using “mini” JET (Jet Erosion Test) d
... Show MoreBACKGROUND: Keratoconus is a progressive non inflammatory bilateral (usually asymmetric) ectatic corneal disease characterized by paraxial stromal thinning ,weakening that lead to corneal surface distortion ,vision loss primarily from irregular astigmatism and myopia and secondly from corneal scar. OBJECTIVE: To evaluate visual and refractive outcomes after intracorneal continuous ring (ICCR) implantation combined with intrapocket corneal collagen cross linking in patient with keratoconus. Setting: Eye Specialty Private Hospital, Baghdad, Iraq. METHODS: This study assessed the results of implantation of Myoring ICCR combined with CXL in 40 eyes with KC. Outcome measures include UDVA,CDVA(spectacle correction),refraction, complications and s
... Show MoreBackground:Periodontal diseases are infectious diseases in which periodontalpathogens trigger chronic inflammatory and immune responses. Interleukine-6 is a multifunctional cytokine playing a central role in inflammation and tissue injury.The aim of the study IS to determine the level of Interleukin-6(IL-6) in saliva of patients with chronic periodontitis compared to healthy subjects. Materials and Methods:The total subjects of the present study is 60, divided into 3 groups; 20 patients with chronic periodontitis with pocket depth(PD ≥4 mm)(group I), 20 patients with pocket depth(PD <4 mm) with clinical attachment loss (group II), and 20 healthy controls with pocket probing depth (PPD ≤ 3 mm) without clinical attachment loss (g
... Show MoreStatic loads exposing to mechanical components can cause cracks, which are lead to form stress concentration regions causing the failure of structure. Generally, from 80% to 90% of structure failure is due to initiation of the cracks. Therefore, it is necessary to repair the crack and reduce its effect on the structure where the effect of the crack is modelled as an additional flexibility to the structure. In the last few years, piezoelectric materials have been considered as one of the most favourable repairing techniques. The piezoelectric material converts the applied voltage on it to a bending moment to counter the bending moment caused by the external load on the beam at the crack location. In this study, the design of the piez
... Show More