Preferred Language
Articles
/
cRY-6okBVTCNdQwCZ47U
Key rate estimation of measurement-device-independent quantum key distribution protocol in satellite-earth and intersatellite links
...Show More Authors

In this work, an estimation of the key rate of measurement-device-independent quantum key distribution (MDI-QKD) protocol in free space was performed. The examined free space links included satellite-earth downlink, uplink and intersatellite link. Various attenuation effects were considered such as diffraction, atmosphere, turbulence and the efficiency of the detection system. Two cases were tested: asymptotic case with infinite number of decoy states and one-decoy state case. The estimated key rate showed the possibility of applying MDI-QKD in earth-satellite and intersatellite links, offering longer single link distance to be covered.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Modern Sport
Special exercises according to the Dynafoot data and its effect on the force index and the performance of the front straight air flip skill on the ground movements mat device
...Show More Authors

View Publication
Publication Date
Thu Jun 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Proposed Entropy Loss function and application to find Bayesian estimator for Exponential distribution parameter
...Show More Authors

The aim of this paper to find Bayes estimator under new loss function assemble between symmetric and asymmetric loss functions, namely, proposed entropy loss function, where this function that merge between entropy loss function and the squared Log error Loss function, which is quite asymmetric in nature. then comparison a the Bayes estimators of exponential distribution under the proposed function, whoever, loss functions ingredient for the proposed function the using a standard mean square error (MSE) and Bias quantity (Mbias), where the generation of the random data using the simulation for estimate exponential distribution parameters different sample sizes (n=10,50,100) and (N=1000), taking initial

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Aug 01 2015
Journal Name
Journal Of Engineering
A Real-Time Fuzzy Load Flow and Contingency Analysis Based on Gaussian Distribution System
...Show More Authors

Fuzzy logic is used to solve the load flow and contingency analysis problems, so decreasing computing time and its the best selection instead of the traditional methods. The proposed  method is very accurate with outstanding computation time, which made the fuzzy load flow (FLF) suitable for real time application for small- as well as large-scale power systems. In addition that, the FLF efficiently able to solve load flow problem of ill-conditioned power systems and contingency analysis. The FLF method using Gaussian membership function requires less number of iterations and less computing time than that required in the FLF method using triangular membership function. Using sparsity technique for the input Ybus sparse matrix data gi

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
GIS Approach for Spatial Distribution Analysis of Groundwater Quality at South-West Part of Basrah
...Show More Authors

Water is necessary for sustainable development and healthy society.  Groundwater, often, is not sufficient and protected for direct human consumption. Due to increase in the density of population the requirement of water is increasing.  In this work, the assessment of groundwater quality was conducted in the south-west part of Basrah province. Spatial variations in the quality of groundwater in the study area have been analyzed utilizing GIS technique. The geochemical parameters of groundwater samples including pH, EC, TDS, Ca, Mg, Na, Cl, HCO3, SO4, and NO3 were assessed in this study. Information maps of the study area have been actually prepared to make use of the GIS spatial

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Apr 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Bayes Estimators for the Parameter of the Inverted Exponential Distribution Under different Double informative priors
...Show More Authors

In this paper, we present a comparison of double informative priors which are assumed for the parameter of inverted exponential distribution.To estimate the parameter of inverted exponential distribution by using Bayes estimation ,will be  used two different kind of information in the Bayes estimation; two different priors have been selected for the parameter of inverted exponential distribution. Also assumed Chi-squared - Gamma distribution, Chi-squared - Erlang distribution, and- Gamma- Erlang distribution as double priors. The results are the derivations of these estimators under the squared error loss function with three different double priors.

Additionally Maximum likelihood estimation method

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Periodicals Of Engineering And Natural Sciences
Bayesian and non-Bayesian estimation of the lomax model based on upper record values under weighted LINEX loss function
...Show More Authors

In this article, we developed a new loss function, as the simplification of linear exponential loss function (LINEX) by weighting LINEX function. We derive a scale parameter, reliability and the hazard functions in accordance with upper record values of the Lomax distribution (LD). To study a small sample behavior performance of the proposed loss function using a Monte Carlo simulation, we make a comparison among maximum likelihood estimator, Bayesian estimator by means of LINEX loss function and Bayesian estimator using square error loss (SE) function. The consequences have shown that a modified method is the finest for valuing a scale parameter, reliability and hazard functions.

View Publication
Scopus (9)
Scopus
Publication Date
Wed Jan 18 2012
Journal Name
Journal Of Engineering
Physical Adsorption, Chemical Adsorption, Surface Area, Pore Size distribution, HDS catalyst
...Show More Authors

Physical and chemical adsorption analyses were carried out by nitrogen gas using ASTM apparatus at 77 K and hydrogen gas using volumetric apparatus at room temperature respectively. These analyses were used for determination the effect of coke deposition and poisoning metal on surface area, pore size distribution and metal surface area of fresh and spent hydrodesulphurization catalyst Co-MoAl2O3 .Samples of catalyst (fresh and spent) used in this study are taken from AL-Dura refinery. The results of physical adsorption shows that surface area of spent catalyst reduced to third compare with fresh catalyst and these catalysts exhibit behavior of type four according to BET classification ,so, the pores of these samples are cylindrical, and the

... Show More
Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Engineering And Applied Sciences
Estimation of concentration of radioactive elements for the Liquid Waste pool in radiochemistry laboratories in Al Tuwaitha site Baghdad-Iraq
...Show More Authors

Scopus (3)
Scopus
Publication Date
Sun Jun 30 2024
Journal Name
Anbar Journal Of Agricultural Sciences
ESTIMATION OF MARKETING EFFICIENCY AND PRODUCTION QUANTITY AT THE BREAK-EVEN POINT FOR COTTON FARMERS IN IRAQ (BAGHDAD PROVINCE: A CASE STUDY)
...Show More Authors

View Publication
Scopus (5)
Scopus Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical & Cellular Archives
RAPID SPECTROPHOTOMETRIC ESTIMATION OF TRACE AMOUNTS OF MEFENAMIC ACID BASED DISPERSIVE LIQUID-LIQUID MICROEXTRACTION OF IN PHARMACEUTICAL PREPARATIONS.
...Show More Authors

A dispersive liquid-liquid microextraction combines with UV-V is spectrophotometry for the preconcentration and determination of Mefenamic acid in pharmaceutical preparation was developed and introduced. The proposed method is based on the formation of charge transfer complexation between mefenamic acid and chloranil as an n-electron donor and a p-acceptor, respectively to form a violet chromogen complex measured at 542 nm. The important parameters affecting the efficiency of DLLME were evaluated and optimized. Under the optimum conditions, the calibration graphs of standard and drug, were ranged 0.03-10 µg mL-1. The limits of detection, quantification and Sandell's sensitivity were calculated. Good recoveries of MAF Std. and drug at 0.05,

... Show More