Preferred Language
Articles
/
bsj-923
Measurements of The Spectroscopic Properties of Hydrogen Iodide Molecules
...Show More Authors

A calculation have been carried out for determination some of the spectroscopic properties of Hydrogen Iodide HI molecules such as, the intensity of the absorption spectrum as a function of the variation of the temperature ranging from 10 to 1000 K. This study shows that the populations and hence intensity of the molecule increased as the temperature increased. Another determination of the maximum rotational quantum number Jmax of N2 , CO , BrF AgCl and HI molecules has been carried out.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 03 2018
Journal Name
Baghdad Science Journal
Synthesis, Spectroscopic Characterization of Cobalt ComplexfromC16H19N3O3S and photodegradation using prepared Nano TiO2catalyst
...Show More Authors

Coblatcomplex has been prepared by reaction between C16H19N3O3S (L) as ligand and metal salt (II). The prepared complex were characterized by infrared spectra, electromic spectra, magnetic susceptibility, molar conductivity measurement and metal analysis by atomic absorption and (C.H.N) analysis. From these studies tetrahedral geometry structure for the complex was suggested. The photodegredation of complex were study using photoreaction cell and preparednanoTiO2 catalyst in different conditions (concentration, temperatures, pH).The results show that the recation is of a first order with activation energy equal to (6.6512 kJ /mol).

Scopus (1)
Scopus Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectroscopic Study for Determination of Amoxicillin Using Cobalt(II) as Complexing Metal
...Show More Authors

         This study includes analytical methods for the determination of the drug amoxicillin trihydrate (Amox.) in some pharmaceutical preparations using Cobalt ion (Co(II)) as complexing metal. The best conditions for complexation were: the reaction time was 20 minutes, pH=1.5 and the best temperature of reaction was 70 ËšC. Benzyl alcohol was the best solvent for extraction the complex.

Keywords: Amoxicillin, Cobalt(II), Complex, Molar ratio.

View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Biochem. Cell. Arch.
SYNTHESIS AND SPECTROSCOPIC STUDY OF N- (METHYLCARBAMOTHIOYL) ACETAMIDE WITH THEIR METAL COMPLEXES
...Show More Authors

A new ligand N-(methylcarbamothioyl) acetamide (AMP) was synthesized by reaction of acetyl chloride with adenine. The ligand was characterized by FT-IR, NMR spectra and the elemental analysis. The transition metal complexes of this ligand where synthesize and characterized by UV-Visible spectra, FT-IR, magnetic suscepility, conductively measurement. The general formula [M(AMP)2Cl2], where M+2 = (Mn, Co, Ni, Cu, Zn, Cd, Hg).

Publication Date
Sun Jun 03 2018
Journal Name
Baghdad Science Journal
Synthesis, Spectroscopic Characterization of Cobalt ComplexfromC16H19N3O3S and photodegradation using prepared Nano TiO2catalyst
...Show More Authors

Coblatcomplex has been prepared by reaction between C16H19N3O3S (L) as ligand and metal salt (II). The prepared complex were characterized by infrared spectra, electromic spectra, magnetic susceptibility, molar conductivity measurement and metal analysis by atomic absorption and (C.H.N) analysis. From these studies tetrahedral geometry structure for the complex was suggested. The photodegredation of complex were study using photoreaction cell and preparednanoTiO2 catalyst in different conditions (concentration, temperatures, pH).The results show that the recation is of a first order with activation energy equal to (6.6512 kJ /mol).

View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Jul 27 2023
Journal Name
Journal Of Optics
Spectroscopic analysis of zinc plasma produced by alternating and direct current jet
...Show More Authors

In this study, a system of nonthermal plasma that was operated under atmospheric pressure and was powered by argon gas was employed. The particular plasma properties are affected by changes in the Ar gas flow ranges from 0.5 to 2.5 l/min, product by stream of the plasma jet that is utilized. By using the aforementioned method generated from AC and DC. After placing Ar gas as the cathode, which represents the negative pole, flows toward the anode, which is represented by a tiny metal plate of Zn measuring 6 × 1 cm2 in size, with a submerged part of 4 cm2 long, with both types of current employed having a high voltage of 13.5 kV and the frequency of AC was 30 kHz, we measured these variable parameters. It has been shown that when argon f

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Jun 27 2018
Journal Name
Iraqi Journal Of Science
Accurate Three Dimensional Coordinates Measurements Using Differential GPS Real Time Kinematic Mode
...Show More Authors

The accurate 3-D coordinate's measurements of the global positioning systems are essential in many fields and applications. The GPS has numerous applications such as: Frequency Counters, Geographic Information Systems, Intelligent Vehicle Highway Systems, Car Navigation Systems, Emergency Systems, Aviations, Astronomical Pointing Control, and Atmospheric Sounding using GPS signals, tracking of wild animals, GPS Aid for the Blind, Recorded Position Information, Airborne Gravimetry and other uses. In this paper, the RTK DGPS mode has been used to create precise 3-D coordinates values for four rover stations in Baghdad university camp. The HiPer-II Receiver of global positioning system was used to navigate the coordinate value. The results wil

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Fri Sep 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Radon-Distribution Measurements With CR-39, LR-115 And CN-85 DeteCtors
...Show More Authors

The  aim  of this  work  is to determine radon and  its decay  product concentratiQns  indoor   and  outdoor   in  different   areas   in  north   and middle  are·a of Iraq by using nuclear  trak detectors  , CR-39  , CN- 85 andLR-115.                        -

For   CR-39    detectors   ,   the   highest    radon    concentration  was

(64.07Bq/m3)indoor and  (52.4  Bq/m3)

outdoor &n

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic study for plasma parameters in co-sputtering system
...Show More Authors

In this work the parameters of plasma (electron temperature Te,
electron density ne, electron velocity and ion velocity) have been
studied by using the spectrometer that collect the spectrum of
plasma. Two cathodes were used (Si:Si) P-type and deposited on
glass. In this research argon gas has been used at various values of
pressures (0.5, 0.4, 0.3, and 0.2 torr) with constant deposition time
4 hrs. The results of electron temperature were (31596.19, 31099.77,
26020.14 and 25372.64) kelvin, and electron density (7.60*1016,
8.16*1016, 6.82*1016 and 7.11*1016) m-3. Optical properties of Si
were determined through the optical transmission method using
ultraviolet visible spectrophotometer with in the range
(

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Minar International Journal Of Applied Sciences And Technology
Electron density spectroscopic measurement in Al laser induced plasma
...Show More Authors

Plasma generated by a 1064 nm pulsed Nd: YAG laser with pulse duration of 10 ns concentrated onto an Al solid target under vacuum pressure was examined spectroscopically. The temperature and electron density specifying the plasma were measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time period range of 300–2000 ns. An echelle spectrograph is utilized to appear the plasma emission lines. The temperature was obtained using the spectral line comparison method and the electron density was calculated using the Stark Broadening (SB) method. The electron density was characterized as a function of laser pulse energy. The time range where the plasma is optically thin and is also in local thermodynamic equilibri

... Show More
Publication Date
Wed Aug 16 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectroscopic Studies of a New Mixed Ligand Complex of Fe(III) in Aqueous Medium
...Show More Authors

A spectrophotometric study of Fe(III) mixed ligand complex has been

performed  involving  1,4 phenylenediamine  (A) and  anthran i lic acid (B) ligand  at 25°C  and  aconstant  ionic strength  of  µ= 0.05M  NaC I04•  The optimum  pH was  found  to be pH=4.l. The format ion  rat io of the new complex   is   determined   to   be   2:1:4  of   Fe(III):(A):(B).   The   molar absorptivity was determined to be :::::: 0.5 x  I 04•  Stepwise spectrum change of the complex formation  is recorded by continuous flow system. Keywords: Mixed ligand

... Show More
View Publication Preview PDF