Preferred Language
Articles
/
bsj-923
Measurements of The Spectroscopic Properties of Hydrogen Iodide Molecules
...Show More Authors

A calculation have been carried out for determination some of the spectroscopic properties of Hydrogen Iodide HI molecules such as, the intensity of the absorption spectrum as a function of the variation of the temperature ranging from 10 to 1000 K. This study shows that the populations and hence intensity of the molecule increased as the temperature increased. Another determination of the maximum rotational quantum number Jmax of N2 , CO , BrF AgCl and HI molecules has been carried out.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 06 2018
Journal Name
Bulletin Of Chemical Reaction Engineering & Catalysis
The Impact of Hydrogen Peroxide as An Oxidant for Solvent-free Liquid Phase Oxidation of Benzyl Alcohol using Au-Pd Supported Carbon and Titanium Catalysts
...Show More Authors

The solvent free oxidation of benzyl alcohol was conducted employing Au and Pd supported catalysts, while utilizing hydrogen peroxide 35% (H2O2) as the oxidant, H2O2 is  very cheap, mild, and an environment friendly reagent, which produced water as the only by-product. Various proportions of Au-Pd catalysts on carbon and titanium oxide activated as supports were synthesized through the use of sol immobilization catalyst synthesis technique. Characterization of the synthesized catalysts was performed using X-Ray Diffraction (XRD), Brunauer-Emmett-Teller (BET), Field Emission Scanning Electron Microscopy (FESEM), and Transmission Electron Microscopy (TEM). It was found that the synthesized Au-Pd/ activated carbon catalyst was  benef

... Show More
View Publication
Scopus (20)
Crossref (15)
Scopus Crossref
Publication Date
Sun Oct 21 2018
Journal Name
Iraqi Journal Of Physics
Spectroscopic study the plasma parameters for Pb doped CuO prepared by pulse Nd:YAG laser deposition
...Show More Authors

In this work, plasma parameters such as, the electron temperature )Te(, electron density ne, plasma frequency )fp(, Debye length )λD(
and Debye number )ND), have been studied using optical emission spectroscopy technique. The spectrum of plasma with different values of energy, Pb doped CuO at different percentage (X=0.6, 0.7, 0.8) were recorded. The spectroscopic study for these mixing under vacuum with pressure down to P=2.5×10-2 mbar. The results of electron temperature for X=0.6 range (1.072-1.166) eV, for X=0.7 the Te range (1.024-0.855) eV and X=0.8 the Te is (1.033-0.921) eV. Optical properties of CuO:Pb thin films were determined through the optical transmission method using ultraviolet visible spectrophotometer within the ra

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic study the plasma parameters for SnO2 doped ZnO prepared by pulse Nd:YAG laser deposition
...Show More Authors

 In this work, plasma parameters such as (electron temperature (Te), electron density (ne), plasma frequency (fp) and Debye length (λD)) were studied using spectral analysis techniques. The spectrum of the plasma was recorded with different energy values, SnO2 and ZnO anesthetized at a different ratio (X = 0.2, 0.4 and 0.6) were recorded. Spectral study of this mixing in the air. The results showed electron density and electron temperature increase in zinc oxide: tin oxide alloy targets. It was located  that  The intensity of the lines increases in different laser peak powers when the laser peak power increases and then decreases when the force continues to increase.

View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Thu Sep 02 2021
Journal Name
Solid State Technology
Spectroscopic Investigation of Charge Transfer Complex And Adsorption of Nitrondye with Curcumin(1) Onmodified Attapulgiteclay
...Show More Authors

A charge transfer complex formed by interaction between nitron as electron donor with curcumin(1 ) as electron acceptor in ethanol at the temperature of theroom to form a colored complex. The optimum conditions of complex formation were investigated by Univariate method. The linearity range of complex was (3.124– 53.11) μg.mL-1 at 442 nm with molar absorptivity (1858.33) L.mol-1.cm-1, Sandell's sensitivity (0.1681μg.cm-2), and with a correlation coefficient (0.9935). Both modified attapulgite and modified attapulgite – complex have been characterized by using , FTIR, SEM, AFM, and XRD. Theadsorption behaviourof complex onto the modified attapulgite has been researchedthrough the variation of the parameters like the adsorbent weight, p

... Show More
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectroscopic Characterization and Antimicrobial Activities of Some Heavy Metals Complexes of 2-hydroxy phenyl piperonalidene
...Show More Authors

An antibacterial and antifungal piperonal-derived compound and its Rh(III), Pd(II), Pt(IV), and Cd(II) metal complexes were synthesized and characterized by spectroscopic methods, conductivity, metal analyses and magnetic moment measurements. The nature of the complexes formed in ethanolic solution was studied following the molar ratio method. From the spectral studies, octahedral geometry was suggested for rhodium (III) and platinum (IV) complexes, while a square planer structure was suggested for palladium (II) complex and a tetrahedral geometry for cadmium (II) complex. Structural geometries of these compounds were also suggested in gas phase by using hyperchem-8 program for the molecular mechanics and semi-empirical calculations.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 02 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The relation among ramal width and length with some cervical and cranio-facial measurements in different skeletal classes
...Show More Authors

Background: The purpose of this study was to assess the relation among the ramal length and width with various cervical and cranio-facial measurements for a sample of Iraqi adults with different skeletal classes. Materials and method: The sample composed of 71 Iraqi adults (36 females and 35 males) with an age ranged between 17-30 years and had different skeletal mal-relations using SNA, SNB and ANB to differentiate between them and assorting them into CL.I, CL.II and CL.III mal-relation. Each individual was subjected to clinical examination and digital true lateral cephalometric radiograph that had been analyzed using AutoCAD 2007 software computer program to determine sixteen linear and ten angular measurements. Descriptive statistics wer

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 23 2025
Journal Name
Journal Of Craniofacial Surgery
Gender Determination in Forensic Dentistry Using Bonwill’s Triangle Measurements From CBCT Scans: A Study on the Iraqi Population
...Show More Authors
Background:

The purpose of this study is to illuminate the role of CBCT in forensic dentistry through variations of mandibular measurements of Bonwill’s triangles in gender determination among the Iraqi population.

Materials and methods:

In this retrospective study 70 CBCT scans were analyzed to measure the Bonwill’s triangle, 35 for males and 35 for females aged between 20 and 50 years, all data were collected at the oral and maxillofacial radiology department in Ghazi AL-Hariri hospital for 3 months, and the data were obtained using a Kavo CBCT device (3D On De

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Baghdad Science Journal
Investigate Spectroscopic Experimental and Theoretical Model for Hemoglobin Nanoscale Solution
...Show More Authors

In the current study, haemoglobin analytes dissolved in a special buffer (KH2PO4(1M), K2HPO4(1M)) with pH of 7.4 were used to record absorption spectra measurements with a range of concentrations from (10-8 to 10-9) M and an absorption peak of 440nm using Broadband Cavity Enhanced Absorption Spectroscopy (BBCEAS) which is considered a simple, low cost, and robust setup. The principle work of this technique depends on the multiple reflections between the light source, which is represented by the Light Emitting Diode 3 W, and the detector, which is represented by the Avantes spectrophotomer. The optical cavity includes two high reflectivity  ≥99%  dielectric mirrors (dia

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (4)
Scopus Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Minar International Journal Of Applied Sciences And Technology
INNOVATE GESTATIONAL AGE ESTIMATION MODEL FOR IRAQI FETUSES BASED ON ULTRASOUND IMAGES MEASUREMENTS
...Show More Authors

Imaging by Ultrasound (US) is an accurate and useful modality for the assessment of gestational age (GA), estimation fetal weight, and monitoring the fetal growth during pregnancy, is a routine part of prenatal care, and that can greatly impact obstetric management. Estimation of GA is important in obstetric care, making appropriate management decisions requires accurate appraisal of GA. Accurate GA estimation may assist obstetricians in appropriately counseling women who are at risk of a preterm delivery about likely neonatal outcomes, and it is essential in the evaluation of the fetal growth and detection of intrauterine growth restriction. There are many formulas are used to estimate fetal GA in the world, but it's not specify fo

... Show More
View Publication
Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Wasit Journal For Pure Sciences
Association between Anthropometric Measurements and some Biochemical Parameters in Premenopausal and Postmenopausal Women
...Show More Authors

Numerous physiological and biochemical changes are linked to menopause. The current study was intended to examine the transforms linked to anthropometric measurements and bone-related factors. In this study of 80 women which included; they comprised 40 premenopausal women and 40 postmenopausal women. waist circumference (WC), body mass index (BMI), hip circumference (HC), moreover waist to hip ratio are among the anthropometric measurements (W-HR) recorded by standard procedures. The plasma samples were tested for the following biochemical parameters: bone-related parameters [calcium (Ca), phosphorus (P), uric acid (UA), alkaline phosphatase (ALP), and erythrocyte sedimentation rate (ESR)] and serological agglutination tests [rheumat

... Show More