Preferred Language
Articles
/
bsj-8111
Determination of Molecular Weight and Viscosity of Irradiated Polystyrene
...Show More Authors

 

The varied applications of polystyrene in various fields of life led to examining the cause of radiation influence on some rheological behavior of commercial Polystyrene (PS) solution in the chloroform (CHCl3) solvent. Polystyrene grains shape samples were irradiated using the radioactive element Cesium- 137 with (9 µci) activity for 10, 20, and 30 minutes. The viscosity of the polymer solution depends on the concentration and size (i.e. molecular weight) of the dissolved polymer. Experimental data showed that the radiation dose affected the value of viscosity (shear, relative, specific, and reduced). The viscosity value significantly reduced at 10 min radiation dose and when increasing the dose, the viscosity value increased up to 30 minutes. Deterioration of the polymer structure was recorded for a 10 minutes radiation dose. With the increase of radiation time, which reached 30 minutes, cross-linking was performed due to the substance gaining additional doses of radiation. The molecular weight of polystyrene increased with the increase of irradiation time, but no value was recorded for a molecular weight higher than 56089, which is for not irradiated polystyrene. The study concluded that the radiation dose is able to control the chemical composition of the polymer, therefore the behavior of the polymer in the solvent is determined by the radiation dose to which it is exposed.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2012
Journal Name
Natural Science
Determination of threshold random gain medium in dye: Polymer films containing TiO<sub>2</sub> nanoparticles
...Show More Authors

View Publication
Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Egyptian Journal Of Botany
Molecular data unravels three freshwater peridinioids in the Baghdad Island Tourist Lake, with reporting Palatinus apiculatus (Peridiniopsidaceae, Peridiniales) as a new record for the Iraqi algal flora
...Show More Authors

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2008
Journal Name
Journal Of Economics And Administrative Sciences
اختبار أساليب تحديد حجم الدفعة المستخدمة في نظام MRP II* دراسة حالة في الشركة العامة لصناعة البطاريات معمل بابل /1
...Show More Authors

      MRP is a system intended for the batch manufacturing of discrete parts including assemblies and subassemblies that should be stocked to support future manufacturing needs.  Due to the useful information provided by MRP it has evolved into a Manufacturing Resources Planning, MRP II, a system that ties the basic MRP system to the other functional areas of the company such as marketing, finance, purchasing, etc.  The objective of this research, which was conducted at the State Company for Batteries Manufacturing, is to test the performance of some popular lot-sizing techniques used within MRP II framework. It is hypothesized that the technique which minimizes the total inventory costs does no

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Novel Approach of Oxidative Coupling Reaction with 1-Naphthol of the Simultaneous Metformin Drug Determination in Either Pharmaceutics Formulations or Environmental Samples of Water Using Homemade CFIA- Merging Zones Techniques
...Show More Authors

A newly developed FIA-merging zones spectrophotometric system, the method is rapid, accurate and sensitive for metformin hydrochloride determination through the oxidation of 1- naphthol by sodium hypochlorite and coupling with metformin.HCl in the presence of sodium hydroxide to form a blue soluble ion pair   and this product was determined using homemade CFIA-Merging zones techniques , at 580 nm. Data treatment shows that linear range is (0.5-35) µg/ ml. The optimization conditions for various chemical and physical conditions of [MTF- NaOCl-α-naphthol-NaOH] system were investigated. The LOD was 0.01µg / ml and LOQ 0.1µg/ml from the lowest concentration of the calibration graph with r2% 99.18 and RSD% did

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 07 2008
Journal Name
Baghdad Science Journal
New Method for Determination of Molybdenum(VI) through Flow Injection Analysis Via the Consumption of Liberated Oxygen from Reaction System Ammonia-Hydrogen peroxide-Molybdenum(VI) in the Presence of Pyrogallol
...Show More Authors

This piece of research work aims to study one of the most difficult reaction and determination due to continuous and rapid variation of reaction products and the reactants. As molybdenum (VI) aid in the decomposition of hydrogen peroxide in alkaline medium of ammomia, thus means a continuous liberation of oxygen which cuases and in a continuous manner a distraction in the measurement process. On this basis pyrogallol was used to absorbe all liberated oxygen and the result is an a clean undisturbed signals. Molybdenum (VI) was determined in the range of 4-100 ?g.ml-1 with percentage linearity of 99.8% or (4-300 ?g.ml-1 with 94.4%) while L.O.D. was 3.5 ?g.ml-1. Interferring ions (cations and anions) were studied and their main effect was red

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n

... Show More
Crossref (2)
Crossref
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Using Factor Analysis In Determine the Important Influenced Factors In Student Outcomes Pheonema From Primary School In The Province Of Baghdad
...Show More Authors

Abstract

The Purpose of This Research is The  Main Factors  In out Comes Phenomena From Primary School Which in Creased in Lost Period in Iraq And to Find Solutions to The This Problem.

In Order to Achieve Al The Aim The Research Choose a Systematic Random Sample of School Records For Students in Some Primary Schools in Karkh and Rusafa and Year of Study (2010-2015) and Size (40) Samples, included  (16) Variable , Collected in Form Prepared by The Research As a Way to Analyze The Data.

Remember to Summarize The (6) Main components Pay a Student to Drop out of Primary Schools in The Province of Baghdad are Arranged As Follows:

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Nov 20 2015
Journal Name
Iraqi Journal Of Science
New Approach for Determination of Oxonium Ion in Inorganic Acids by Quenched Fluorescence of Analytically Interested Species via the Liberated Bromine Using Continuous Flow Injection Laser Diode Fluorimeter Analyser
...Show More Authors

A new method is characterized by simplicity, accuracy and speed for determination of Oxonuim ion in ionisable inorganic acid such as hydrochloric (0.1 - 10) ,Sulphuric ( 0.1 - 6 ),nitric ( 0.1 - 10 ), perchloric ( 0.1 - 7 ), acetic (0.1 - 100 ) and phosphoric ( 0.1 - 30 ) ( mMol.L-1 )acids. By continuous flow injection analysis. The proposed method was based on generation of bromine from the Bro-3-Br-- H3O+. Bromine reacts with fluorescein to quenches the fluorescence . A sample volume no.1 (31μl) and no.2 (35μl) were used with flow rate of 0.95 mL.min-1 using H2O line no.1as carrier stream and 1.3 mL.min-1 using fluorescein sodium salt line no.2. Linear regression of the concentration ( mMol.L-1 ) Vs quenched fluorescence gives a correla

... Show More
View Publication
Publication Date
Fri Apr 01 2022
Journal Name
Baghdad Science Journal
Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
...Show More Authors

This study was undertaken to introduce a fast, accurate, selective, simple and environment-friendly colorimetric method to determine iron (II) concentration in different lipstick brands imported or manufactured locally in Baghdad, Iraq. The samples were collected from 500-Iraqi dinars stores to establish routine tests using the spectrophotometric method and compared with a new microfluidic paper-based analytical device (µPAD) platform as an alternative to cost-effective conventional instrumentation such as Atomic Absorption Spectroscopy (AAS). This method depends on the reaction between iron (II) with iron(II) selective chelator 1, 10-phenanthroline(phen) in the presence of reducing agent hydroxylamine (HOA) and sodium acetate (NaOAc) b

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
اثر تطبيق قواعد حوكمة الشركات في مصداقية التقارير المالية وفي تحديد وعاء ضريبة الدخل: دراسة في قسم الشركات في الهيئة العامة للضرائب
...Show More Authors

Corporate governance has the great concern from the international and regional, institutions and organizations especially after the current financial crisis. It became a fertile field for research and study.

So an urgent need was to do research links the relationship between taxes and corporate governance to take advantage of Its multiple positives because corporate governance helps in the elimination of the conflict, to achieve harmony and balance between the interests of different groups interested in the company whether from within or from outside, financial authority is one of the these categories.

  The aim of this research is to achieve a set of objectives including:

  1. make use of the

... Show More
View Publication Preview PDF