Preferred Language
Articles
/
bsj-6644
Evaluation Method of Mesh Protocol over ESP32 and ESP8266
...Show More Authors

Internet of Things (IoT) is one of the newest matters in both industry and academia of the communication engineering world. On the other hand, wireless mesh networks, a network topology that has been debate for decades that haven’t been put into use in great scale, can make a transformation when it arises to the network in the IoT world nowadays. A Mesh IoT network is a local network architecture in which linked devices cooperate and route data using a specified protocol. Typically, IoT devices exchange sensor data by connecting to an IoT gateway. However, there are certain limitations if it involves to large number of sensors and the data that should be received is difficult to analyze. The aim of the work here is to implement a self-configuring mesh network in IoT sensor devices for better independent data collection quality. The research conducted in this paper is to build a mesh network using NodeMCU ESP 8266 and NodeMCU ESP 32 with two types of sensor, DHT 11 and DHT 22. Hence, the work here has evaluated on the delay performance metric in Line-of-Sight (LoS) and Non-Line-of-Sight (nLos) situation based on different network connectivity. The results give shorter delay time in LoS condition for all connected nodes as well as when any node fail to function in the mesh network compared to nLoS condition. The paper demonstrates that the IoT sensor devices composing the mesh network is a must to leverage the link communication performance for data collection in order to be used in IoT-based application such as fertigation system. It will certainly make a difference in the industry once being deployed on large scale in the IoT world and make the IoT more accessible to a wider audience.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 30 2025
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Improving the elimination of methyl orange dye by combining electrocoagulation system with the adsorption process by oven-dried alum sludge: adopting different combined systems
...Show More Authors

   Due to their recalcitrant characteristics, Azo dyes such as methyl orange (MO) are extremely poisonous substances, making their removal from textile industry wastewater a major problem. By employing various EC-Adsorption combined system configurations and reusing alum sludge as an adsorbent, the current study seeks to investigate the efficiency of these various systems in removing MO dye. To estimate their benefits and limitations, experiments were carried out utilizing nickel foam (NiF) and aluminum plate (Al plate) as anodes, and stainless-steel mesh (SS mesh) as cathode in the presence of alum sludge as an adsorbent in all systems. The EC-Adsorption combined system with NiF as anode and two SS meshes as cathodes with 10 g/L

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 20 2021
Journal Name
College Of Islamic Sciences
Positive images in the Holy Quran The story of Solomon - peace be upon him - in Surat An-Naml is a model An objective study
...Show More Authors

God Almighty put in his great book secrets that do not end, and wonders that do not expire, for he is the one from which the scholars are not satisfied, and he does not create due to the multitude of response, and it is the comprehensive and inhibitory book that God conceals to the worlds, and he challenged the two heavyweights to come up with something like it.

At all times, issues arise in the Noble Qur’an that fit the needs of the people of that time and their culture, for it is an eternal book, characterized by the ability to give, extend and respond to addressing the problems of the age and its variables, when the Arabs had little luck at the time of the message’s descent from the scientific culture, and their proficienc

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Applied Energy
Hourly yield prediction of a double-slope solar still hybrid with rubber scrapers in low-latitude areas based on the particle swarm optimization technique
...Show More Authors

View Publication
Scopus (35)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Measuring Lower Uterine Segment Thickness Using Abdominal Ultrasound to Predict Timing of Cesarean Section in Women with Scarred Uterus at Elwiya Maternity Teaching Hospital
...Show More Authors

Background: Ultrasonography has been used to examine the thickness of the lower uterine segment in women with previous cesarean sections in an attempt to predict the risk of scar dehiscence during subsequent pregnancy. The predictive value of such measurement has not been adequately assessed. Objectives: To correlate lower uterine segment thickness measured by trans abdominal ultrasound in pregnant women with previous cesarean section with that measured during cesarean section by caliper and to find out minimum lower uterine segment thickness indicative of integrity of the scar.Methods: A prospective observational study at Elwyia Maternity Teaching Hospital, from January 2011 to January 2012. A total of 143 women were enrolled in the stu

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 21 2025
Journal Name
Journal Of Advances In Information Technology
Towards Accurate SDG Research Categorization: A Hybrid Deep Learning Approach Using Scopus Metadata
...Show More Authors

The complexity and variety of language included in policy and academic documents make the automatic classification of research papers based on the United Nations Sustainable Development Goals (SDGs) somewhat difficult. Using both pre-trained and contextual word embeddings to increase semantic understanding, this study presents a complete deep learning pipeline combining Bidirectional Long Short-Term Memory (BiLSTM) and Convolutional Neural Network (CNN) architectures which aims primarily to improve the comprehensibility and accuracy of SDG text classification, thereby enabling more effective policy monitoring and research evaluation. Successful document representation via Global Vector (GloVe), Bidirectional Encoder Representations from Tra

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Physics: Conference Series
The effect of left ventricle ischemia severity on cardiac performance appeared on ejection fraction using radioactive TC <sup>99m</sup> MIBI in comparison with echocardiography
...Show More Authors
Abstract<p>Ischemic heart disease is a major causes of heart failure. Heart failure patients have predominantly left ventricular dysfunction (systolic or diastolic dysfunction, or both). Acute heart failure is most commonly caused by reduced myocardial contractility, and increased LV stiffness. We performed echocardiography and gated SPECT with Tc<sup>99m</sup> MIBI within 263 patients and 166 normal individuals. Left ventricular end systolic volume (LVESV), left ventricular end diastolic volume (LVEDV), and left ventricular ejection fraction (LVEF) were measured. For all degrees of ischemia, there was a significant difference between ejection fraction values measured by SPECT and echo</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of nano-hydroxy apatite on re-mineralize white spot lesions prior to orthodontic adhesive removal by different techniques (An In vitro comparative study)
...Show More Authors

Background: White-spot lesion is one of the problems associated with the fixed orthodontic treatment. The aims of this in-vitro study were to investigate enamel damage depth on adhesive removal when the adhesive were surrounded by sound, demineralized or demineralized enamel that had been re-mineralized prior to adhesive removal using 10% Nano-Hydroxy apatite and to determine the effect of three different adhesive removal techniques. Materials and methods: Composite resin adhesive (3M Unitek) was bonded to 60 human upper premolars teeth which were randomly divided in to three groups each containing ten sound teeth and ten teeth with demineralized and re-mineralized lesions adjacent to the adhesive. A window of 2 mm was prepared on the bucca

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Basrah Journal Of Surgery
Can Hyaluronic acid gel enhance wound healing faster than Advanced Platelets Rich Fibrin following surgical removal of impacted mandibular third molars? A Randomized Controlled Trial
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Thu Jan 06 2022
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of an Instructional Program on Patientsꞌ Knowledge about Home Safety While Receiving Anti -Cancer Medications at Al- Karama Teaching Hospital in Al-Kut City
...Show More Authors

Objectives: To determine the effectiveness of the instructional program on patients’ knowledge about home safety while receiving anti-cancer treatment at  Al- Karama Teaching Hospital in Al-Kut City.

Methodology:   A quasi-experimental design is conducted through the application of a pre-test and post-test approach for the study and control groups from February 5th, 2020 to April 25th, 2020. A non–probability (purposive) sample of (50) patients treated at the Blood Disease and Oncology Center is selected and divided into two groups. Each group contains (25) patients as control and study groups. An instrument is constructed that is comprised of two parts; t

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
Aip Conference Proceedings
Determination of cefotaxime-sodium at nanoscale level by a microflow injection cell via measuring turbidity using five irradiation sources (WSLEDs) with a single solar cell
...Show More Authors

This work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref