Urinary tract infections (UTIs) mean microbial pathogens in the urethra or bladder (lower urinary tract). Important risk factors for recurrent UTI include obstruction of the urinary tract, use of a bladder catheter or a suppressed immune system. This study aims to isolate and identify bacteria from patients with TCC-bladder cancer or patients with a negative cystoscope and estimate antibiotic susceptibility patterns and evaluate some of the virulence factors. From a total of 62 patients with TCC-BC or negative cystoscope, only 35 favorable bacterial growths were obtained, including Escherichia coli (UPEC), a significant bacterial isolate, and Stenotrophomonas maltophilia. The percentage of multi drug-resistance bacteria (MDR) was identified in (62.8%) while the extended drug-resistance bacteria (XDR) was (28.5%). All isolates were producer for biofilm either moderately 18/35 (49%) or strongly 18/35 (51%). Only 25/35 (71%) isolates were produced for siderophore, while 10/35 (29%) isolates were non-produced. Inducing cytochrome P450 expression protein was seen in (14/35) 40% isolates. In conclusion, patients with TCC-BC or negative cystoscope who had a urinary catheter or immune-compromised were at high risk of infecting with nosocomial or opportunistic pathogens, which could be develop antibiotic resistance, the central problem in the cohort of patients undergoing chemotherapy or immune cancer therapy
In this paper, a comparison between horizontal and vertical OFET of Poly (3-Hexylthiophene) (P3HT) as an active semiconductor layer (p-type) was studied by using two different gate insulators (ZrO2 and PVA). The electrical performance output (Id-Vd) and transfer (Id-Vg) characteristics were investigated using the gradual-channel approximation model. The device shows a typical output curve of a field-effect transistor (FET). The analysis of electrical characterization was performed in order to investigate the source-drain voltage (Vd) dependent current and the effects of gate dielectric on the electrical performance of the OFET. This work also considered the effects of the capacitance semiconductor on the performance OFETs. The value
... Show MoreThis study aims to show, the strength of steel beam-concrete slab system without using shear connectors (known as a non-composite action), where the effect of the friction force between the concrete slab and the steel beam has been investigated, by using finite element simulation.
The proposed finite element model has been verified based on comparison with an experimental work. Then, the model was adopted to study the system strength with a different steel beam and concrete slab profile. ABAQUS has been adopted in the preparation of all numerical models for this study.
After validation of the numerical models, a parametric study was conducted, with linear and non-linear Regression analysis. An equation re
... Show MoreThe aim of the research is to identify the relationship between health anxiety associated with Coronavirus (Covid 19) and its relationship to health behavior among Baghdad University employees, as well as to identify the differences in health anxiety and health behavior according to the variables (gender, occupation, and age). To achieve the objectives of the research, a scale was designed to measure the health anxiety in addition to the adoption of the health behavior scale prepared by (Renner & Schwarzer, 2005). The two scales were applied to a sample of (277) academics and (206) employees, while the number of students was (667). The sample was chosen by electronic application from a number of colleges at Al-Jadiriyah Complex. Afte
... Show MoreIn this research, the influence of the orientation and distance factors on the lowest usable frequency (LUF) parameter has been studied theoretically. The calculations of the (LUF) parameter have been made using the (VOACAP) international communication model for the connection links between the capital Baghdad and many other locations that distributed on different distances and directions over the Middle East region. The results shown in this study indicate there is a slight affection of the link direction (orientation) on the LUF parameter, while the influence of the distance factor is more significant on the values of the LUF parameter. The day/night effect appears for the long distance HF links (i.e. more than a 500 Km)
The deterioration of buried sewers during their lifetime can be affected by several factors leading to bad performance and can damage the infrastructure similar to other engineering structures. The Hydraulic deterioration of the buried sewers caused by sewer blockages while the structural deterioration caused by sewer collapses due to sewer specifications and the surrounding soil characteristics and the groundwater level. The main objective of this research is to develop deterioration models, which are used to predict changes in sewer condition that can provide assessment tools for determining the serviceability of sewer networks in Baghdad city. Two deterioration models were developed and tested using statistical software SPSS, the
... Show MorePrediction of the formation of pore and fracture pressure before constructing a drilling wells program are a crucial since it helps to prevent several drilling operations issues including lost circulation, kick, pipe sticking, blowout, and other issues. IP (Interactive Petrophysics) software is used to calculate and measure pore and fracture pressure. Eaton method, Matthews and Kelly, Modified Eaton, and Barker and Wood equations are used to calculate fracture pressure, whereas only Eaton method is used to measure pore pressure. These approaches are based on log data obtained from six wells, three from the north dome; BUCN-52, BUCN-51, BUCN-43 and the other from the south dome; BUCS-49, BUCS-48, BUCS-47. Along with the overburden pr
... Show MoreThe gas material balance equation (MBE) has been widely used as a practical as well as a simple tool to estimate gas initially in place (GIIP), and the ultimate recovery (UR) factor of a gas reservoir. The classical form of the gas material balance equation is developed by considering the reservoir as a simple tank model, in which the relationship between the pressure/gas compressibility factor (p/z) and cumulative gas production (Gp) is generally appeared to be linear. This linear plot is usually extrapolated to estimate GIIP at zero pressure, and UR factor for a given abandonment pressure. While this assumption is reasonable to some extent for conventional reservoirs, this may incur