Preferred Language
Articles
/
bsj-556
The Effect of Grain Boundaries on Schottky Diode Parameters
...Show More Authors

The activation energy and optical band gap of different regions (p-type) polysilicon have been measured. Both microscopic studies and current-voltage characteristics of diodes prepared on different surface regions were carried out. Comparison of diodes parameters and microscopic studies indicate that the type of angles between boundaries has a significant effect on diodes parameters while the boundary lengths per unit area has less effect. The mechanism of Al-interaction with grain boundaries and their intersecting points at different temperature were also studies. The X-ray fluorescence spectrometry has been used for detection of diffused A1%.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 02 2022
Journal Name
Basic And Clinical Andrology
Effects of Covid-19 vaccination on different semen parameters
...Show More Authors
Abstract<sec> <title>Background

The possible effects of COVID-19 vaccines on reproductive health and male fertility in particular have been discussed intensely by the scientific community and the public since their introduction during the pandemic. On news outlets and social media platforms, many claims have been raised regarding the deleterious effects of COVID-19 vaccines on sperm quality without scientific evidence. In response to this emerging conflict, we designed this study to evaluate and assess the effect of the Pfizer-BioNTech mRNA COVID-19 vaccine on male fertility represented by the semen analysis parameters.

... Show More
View Publication Preview PDF
Scopus (22)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Tue Sep 04 2018
Journal Name
Al-khwarizmi Engineering Journal
Investigation of CNC Milling Machining Parameters on Surface Roughness
...Show More Authors

Milling Machining is a widely accepted nontraditional machining technique used to produce parts with complex shapes and configurations. The material is removed in two stages roughing and finishing, the flat end cutter removed the unwanted part of material, then finished by end mill cutter. In milling technique, the role of machining factors such as cutting depth, spindle speed and feed has been studied using Taguchi technique to find its effectiveness on surface roughness.  Practical procedure is done by Taguchi Standard matrix. CNC milling is the most conventional process which is used for removing of material from workpiece to perform the needed shapes. The results and relations indicate that the rate of feed is v

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Effect of magnetic water in the some parameters of growth & activity of some enzymes in the ( Raphanus raphanistrum L.) Plant
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Tue Dec 13 2005
Journal Name
Iraqi Journal Of Laser
Clinical Observation and Performance of High Power Diode Laser in the Treatment of Oral Lesions
...Show More Authors

In this work, oral lesions belong to 17 patients, 7 males and 10 females. Their ages range between 15 and 45 years. Follow up was conducted after one day, 7 days, 14 days, one month, and finally 3 months postoperatively. The study lasted for 1.5 year. Surgical diode laser with wavelength of 810 ± 20 nm, with two power levels of 10 and 15 W were used in contact and in non-contact mode via optical fiber. The postoperative outcome revealed; greater haemostatic capability, dry, sealed wound and noticeable lack in pain sensation

View Publication Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Effect of the Aquatic Plant Hydrella vorticellata as a Fertilizer on Seed Germination and some Chemical and Cytogenetics Parameters in the cell of Hordeum vulgare and Vicia faba
...Show More Authors

The present study is concerned with studying the effect of aquatic plant Hydrella vorticellata with the concentration of 10 and 20 gm/2 K gm soil on percentage and growth rate of germinating seeds of Hordeum vulgare and Vicia faba. More overs, the quantitative amount of NPK in both tested plants and Hydrella vorticellata, are estimated as an organic fertilizer. It has also been find the total number of root cells, the number of dividing cells, and stages of mitosis. The study reveales, that there are no significant differences between the concentration of hydrella used in germination percentage, growth rate, wet and dry weight. While there are differences in the plants containing NPK. The number of cells dividing stages and number of divid

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Ovonic Research
Color-tunable of organic light emitting diode MEH-PPV: CNTs
...Show More Authors

Organic light emitting diodes (OLEDs) were fabricated containing host molecule of conjugated polymer MEH-PPV poly (2-methoxy-5-(2'-ethylhexyloxy)-1,4-phenlenevinylene) which was dissolved in chloroform solvent and doped with guest molecules MWCNTs that were dissolved in DMF solvent with different volume ratios 0.05 and 0.15, nanocomposite system which acts as active layer in OLEDs device. The Poly(3,4-ethylenedioxythiophene):poly-(styrenesulfonate) "PEDOT:PSS" and Tris98-hydroxyquinoline) aluminum "Alq3" as hole transport layer HTL and electron transport layer ETL were used respectively, to enhanced the injection charge from the electrodes to the active layer. Spin coating method used for achieving facile and low cost OLED. The absorption s

... Show More
Scopus (5)
Scopus
Publication Date
Mon Dec 10 2007
Journal Name
Iraqi Journal Of Laser
Evaluation of breast mass excision by 810 nm diode laser
...Show More Authors

Breast mass is by far the most important clinical problem that concerns the breast today. This study was carried out to evaluate diode laser as a cutting tool in breast mass excision and as a hemostatic tool for coagulation during surgery. Using 810 nm diode laser with optical fiber 600μm in diameter of conical tip, udder (cow's breast) tissue, and three female patients (mean age of 35.5 y with clinically palpable breast mass) had been used in this study. The patients were followed up regularly postoperatively. In preliminary work on udder tissue, the power needed for cutting and excision was 15W (power density= 5.3 kW/cm2). The time consumed for excision of a piece of udder tissue, 40×10×3 mm in dimensions was 5 min. The depth range

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 22 2023
Journal Name
Eastern-european Journal Of Enterprise Technologies
Evaluating the impact of structure parameters on the acoustic performance of an exhaust muffler with shells
...Show More Authors

Recently, environmental noise has arisen from various sources, such as those from exhaust mufflers of combustion engines found in cars, trucks, or power generators, which produce significant noise during their operation. Controlling the radiated noise from these mufflers is a major factor in improving acoustic comfort and minimizing the impact on the surrounding communities. Numerous research has been presented for this reason by modification of the internal structure of the exhaust muffler. The main objective of this work is to reduce the noise level emitted from exhaust mufflers. This can be achieved by adjusting structure parameters to attenuate the surrounding environment's radiated noise. Analysis of pressure-wave propagation h

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref