Preferred Language
Articles
/
bsj-556
The Effect of Grain Boundaries on Schottky Diode Parameters
...Show More Authors

The activation energy and optical band gap of different regions (p-type) polysilicon have been measured. Both microscopic studies and current-voltage characteristics of diodes prepared on different surface regions were carried out. Comparison of diodes parameters and microscopic studies indicate that the type of angles between boundaries has a significant effect on diodes parameters while the boundary lengths per unit area has less effect. The mechanism of Al-interaction with grain boundaries and their intersecting points at different temperature were also studies. The X-ray fluorescence spectrometry has been used for detection of diffused A1%.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Waterpipe Smoking Effect on Clinical Periodontal Parameters, Salivary Flow Rate and Salivary pH in Chronic ‎Periodontitis Patient
...Show More Authors

Background: Waterpipe tobacco smoking has become common especially among young people, Waterpipe smoking misconcepted as a safer mean of smoking, so in this study we will highlight the effect of Waterpipe smoking ‎on periodontal and oral health.‎ Materials and method. The selected ‎‎‎100 male subjects of 30-40 years, ‎categorized into 4 groups (each group ‎‎25 subject): Waterpipe smoker ‎with ‎healthy periodontium, ‎Waterpipe smoker ‎‎with chronic periodontitis, Non-‎‎smoker ‎with healthy periodontium and Non-smoker ‎with chronic periodontitis. Whole ‎unstimulated ‎saliva was collected. Clinical measurements: plaque ‎index

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Wed Oct 17 2018
Journal Name
Iraqi Journal Of Laser
Thermal Effects of 940 nm Diode Laser on Dental Socket Blood after Teeth Extraction for Diabetic Patients
...Show More Authors

Abstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
identification of fungi and their toxins associated with imported rice grain to iraq
...Show More Authors

The study included the investigation of fungi ringed and inventory and Aflatoxins in rice and recorded average temperatures and humidity 22.75 degree Celsius and 13.2% respectively were obtained 1356 isolation innate possible diagnosis 15 species inherent in rice imported back to 8 races represented races b Fusarium , Cladosporium, Aspergillus and Alternaria

View Publication Preview PDF
Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison between the effects of Aloe vera and chlorhexidine on clinical periodontal parameters
...Show More Authors

Background: Periodontal diseases are one of the major dental pathologies that affect human populations worldwide at high prevalence rates The term periodontal disease usually refers only to plaque related inflammatory disease of the dental supporting tissues. Mouth rinses which act as an anti-plaque agents mostly used as adjuncts to oral hygiene. Aims of the study: To Estimate and compare the effects of Aloe vera relative to chlorhexidine on the clinical periodontal parameters (plaque index, gingival index, bleeding on probing). Material and method: A total of 44 subjects with plaque-induced gingivitis, baseline of data were collected for (PLI, GI, and BOP) and underwent oral hygiene instruction, scaling and polishing, then divided into:

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Fri Mar 01 2024
Journal Name
Baghdad Science Journal
Isotherms and Thermodynamic Parameters of Metoprolol Drug Adsorption on the Prepared Mesoporous Silica
...Show More Authors

In this study, mesoporous silica (MPS) is made using the sol-gel method from a cheap source (Na2SiO3) using the surfactant hydroxycetyl hydroxyethyl dimonium chloride as a template. The task is the adsorption-based removal of the medication metoprolol (MP) at concentrations between 10 and 50 ppm. Variables such as: contact time, dose of adsorbent, starting concentration of adsorbate, and adsorption temperature were studied which show the equilibrium time and adsorbent dose are 40 min and 0.05 g respectively. The Langmuir, Freundlich, Temkin, and Dubinin-Radushkevich isotherm models were fitted to the data obtained from the experiments. Comparing the outcomes showed that, of the four investigated isotherm models, the Freundlich equation m

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (4)
Scopus Crossref
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Influence of 805 nm Diode Laser on Plasmid Content of Some Locally Isolated Escherichia coli and Proteus Mirabilis
...Show More Authors

This work aimed to investigate the effect of Diode laser 805 nm on plasmid DNA and RNA
contents of some Gram negative bacteria represented by Escherichia coli and Proteus mirabilis isolates
.Plasmid extraction was done using two methods (Salting out and CTAB method).Different powers and
pulse repetition rates for 805 nm Diode Laser were used to study this effect. Results revealed that the
plasmid profile of the two species were highly affected using (2, 3) W at different frequencies including
5and 10 kHz as compared with 1 kHz while plasmids were gradually disappeared at 1W, 10 kHz. In the
same time the shining of RNA was also decreased gradually then disappeared with increasing powers
especially at 2W and 10 kHz cau

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
A 980nm Diode Laser Clot Formation of the Rabbit’s Dental Sockets after Teeth Extraction
...Show More Authors

The aim of this research work is to evaluate the use of 980 nm diode laser in clotting the blood
in the bone socket after tooth extraction. The objective is to prevent possible clot dislodgement which is
a defect that may lead to possible infection. A number of rabbits were irradiated using 980nm CW mode
diode laser, 0.86W power output for 9s and 15s exposure time. The irradiated groups were studied
histopathologically in comparison with a control group. Results showed that laser photothermal
coagulation was of benefit in minimizing the possibility of the incidence of postoperative complications.
The formation of the clot reduces the possibility of bleeding and infection.

View Publication Preview PDF
Publication Date
Thu Jan 29 2026
Journal Name
Journal Of Optics
A review on beam-shaping techniques for high-power and compact fiber-coupled diode laser system
...Show More Authors

View Publication
Crossref
Publication Date
Sat Sep 09 2023
Journal Name
Progress In Electromagnetics Research C
Compact Dual-polarized Reconfigurable MIMO Antenna Based on a Varactor Diode for 5G Mobile Terminal Applications
...Show More Authors

View Publication Preview PDF
Scopus (11)
Crossref (4)
Scopus Crossref
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
Influence of Gold Concentration on the Main Detection Parameters of Ge-Au Photoconductive Detector
...Show More Authors

Ge-Au infrared photoconductive detection was prepared from germanium single crystal which were doped with different gold concentration using thermal evaporation. The spectral resonsivity (Rλ), spectral detectivity (D*) were determined as function of wavelength, also the resistance, conductivity in dark and with illumination to infrared radiation, the gain and relative photo response have been measured with different gold concentration. Remarkable improvements in the photoresponse gain were observed for the highest resistance specimen at the expense of spectral detectivity values.

View Publication Preview PDF