Preferred Language
Articles
/
bsj-527
Determination of Serum CA125 and evaluate its efficiency as screening tool For Early Detection of Ovarian Tumors
...Show More Authors

Epithelial ovarian cancer is the leading cause of cancer deaths in women. To date, an effective screening tool for ovarian cancer has not been identified Several clinical and biological factors including serum cancer antigen 125 (CA- 125) have been assessed for prognostic and predictive relevance CA-125 is an epithelial marker derived from coelomic epithelium. It is elevated in 90% of advanced ovarian cancers and in 50% of early ovarian cancers while 20% of ovarian cancers have low or no expression of CA- 125 CA-125 concentrations were measured by Mini Vidas test (VIDAS CA125 II / BIOMERIEUX / France). The median CA-125 levels were significantly higher in the sera of ovarian cancer patients than in those with benign tumors and in healthy controls. However in correlation with stages the results showed that Patients with stage II have highly significant differences in level of serum CA125 compare with stage I in and stage III.CA125 showed low sensitivity to detect stage I carcinoma of the ovary which limits its value as an initial screening tool therefore combining of CA125 with other markers might enable improved early detection of ovarian cancer as compared with use of this marker alone.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Development of Green Method for Trace Determination of Bendiocarb in Real Samples Using Emerson
...Show More Authors

In this study, cloud point extraction combined with molecular spectrometry as an eco-friendly method is used for extraction, enrichment and determination of bendiocarb (BC) insecticide in different complex matrices. The method involved an alkaline hydrolysis of BC followed Emerson reaction in which the resultant phenol is reacted with 4-aminoantipyrene(4-AAP) in the presence of an alkaline oxidant of potassium ferric cyanide to form red colored product which then extracted into micelles of Triton X-114 as a mediated extractant at room temperature. The extracted product in cloud point layer is separated from the aqueous layer by centrifugation for 20 min and dissolved in a minimum amount of a mixture ethanol: water (1:1) followed

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Dec 04 2014
Journal Name
Engineering And Technology Journal
Optimization of the Time Required for Determination of the Total Dissolved Salts in Soil ‫
...Show More Authors

Publication Date
Fri Jan 13 2023
Journal Name
Journal Of Research In Medical And Dental Science
Phytochemical Screening and Antibacterial Effect of Stevia Rebaudiana (Bertoni) Alcoholic Leaves Extract on Streptococcus Oralis (Dental Plaque’s Primary Colonizer)
...Show More Authors

Phytochemical Screening and Antibacterial Effect of Stevia Rebaudiana (Bertoni) Alcoholic Leaves Extract on Streptococcus Oralis (Dental Plaque’s Primary Colonizer), Manar Ibrahim

View Publication Preview PDF
Publication Date
Tue Sep 24 2019
Journal Name
Journal Of Petroleum Research And Studies
Lithofacies Characterization of the Early – Middle Miocene Succession, Case-Study, South Iraq
...Show More Authors

The Early – Middle Miocene Ghar and Lower Fars sedimentary succession at the representative oil-well Nu-18 of the Nahr Umr oil field south Iraq; is taken by this study to investigate the sedimentological to reservoir rock facies buildups and related reservoir zonation; as first rock-typing attempt for the both formations. The sedimentological characterization of the Early Miocene Ghar formation is mainly comprised by successive buildups of sands-gravels and sandstones, whereas; the Middle Miocene Lower Fars formation is started by limestone, limestone-marly/marl anhydritic, upgraded into interbedded-series of marl and anhydrite facies, with less-common occurrences of thin-sandstone interlayers, terminated by marl-sandy-secti

... Show More
View Publication
Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Synthesis New Liquid Selective Electrodes of Ciprofloxacin Hydrochloride for Determination Ciprofloxacin in Pure form and Pharmaceuticals Preparation.
...Show More Authors

New membrane electrodes for determination of ciprofloxacin hydrochloride were prepared depending on ciprofloxacin hydrochloride - phosphotungstic acid (CFH-PT) as an active material and these electrodes were made with three plasticizers: Di-octylphenylphosphonate(DOPH), Di-butyl phosphate (DBP)Tri-n-butyl phosphate(TBP), in PVC matrix. One of the ciprofloxacin electrodes was gave Nernstian slope equal to 57.21 mV/ decade for DOPH membrane with concentration range from 1.5×10-5 to1.0×10-1 M, and detection limit equal to 1.5×10-6 M .Lifetime was 93 days. Non- Nernstian responses equal to 39.40 and 30.70 mV/ decade for membranes DBP, TBP, respectively. These electrodes were gave concentration range from 1.0× 10-5 to 1.0×10-2 and from 4.0

... Show More
View Publication Preview PDF
Scopus (9)
Scopus Crossref
Publication Date
Thu Jan 08 2015
Journal Name
Chemical And Process Engineering Research
Uni and Simplex Optimization for the Spectrophotometric Determination of Erythromycin ethylsuccinate Drug via Charge-Transfer Complex Formation
...Show More Authors

Charge transfer complex formation method has been applied for the spectrophotometric determination of erythromycin ethylsuccinate, in bulk sample and dosage form. The method was accurate, simple, rapid, inexpensive and sensitive depending on the formed charge- transfer complex between cited drug and, 2,3- Dichloro-5,6-dicyano-p- benzoquinone (DDQ) as a chromogenic reagent. The formed complex shows absorbance maxima at 587 nm against reagent blank. The calibration graph is linear in the ranges of (10 - 110) μg.mL-1 with detection limit of 0.351μg.mL-1. The results show the absence of interferences from the excipients on the determination of the drug. Therefore the proposed method has been successfully applied for the determination of eryth

... Show More
Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 01 2024
Journal Name
Baghdad Science Journal
Simultaneous spectrophotometric method for determination of both ciprofloxacin and cephalexin by using H-point standard addition method
...Show More Authors

طريقة سهلة وبسيطة ودقيقة لتقدير السبروفلوكساسين  في وجود السيفاليكسين او العكس بالعكس في خليط منهما. طبقت الطريقة المقترحة بطريقة الاضافة القياسية لنقطة بنجاح في تقدير السبروفلوكساسين بوجود السيفاليكسين كمتداخل عند الاطوال الموجية 240-272.3 نانوميتر وبتراكيز مختلفة من  السبروفلوكساسين 4-18 مايكروغرام . مل-1 وكذلك تقدير السيفاليكسين بوجود السبروفلوكساسين الذي يتداخل باطوال موجية 262-285.7 نانوميتر وبتراكيز مخ

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Feb 04 2023
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Designing an electronic vest to evaluate movement abilities in foil fencers
...Show More Authors

Fencing sport coaches seek fencers who have high velocity and work hard to develop it through training. The research problem lies on when measuring movement abilities through some tests. Manual measurement does not give reasonable impartiality of timing because there is a time-frame between the movement of the fencer and the speed of the movement of the human time setter. Therefore, the authors sought to design an electronic vest to evaluate movement abilities in foil fencers. The study design was experimental, with 12 Iranian foil fencers of the national team, who were divided into two equal groups of 6 fencers. Moreover, there were 12 students from Physical Education and Sport Sciences that worked on the scientific f

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Practice Periodical On Structural Design And Construction
Case Study to Evaluate Work-Zone Safety Technologies in Highway Construction
...Show More Authors

View Publication
Scopus (17)
Crossref (17)
Scopus Clarivate Crossref