Preferred Language
Articles
/
bsj-2790
Determination of Water-Soluble Vitamins in Iraqi Honey Bee and Compare with Others Types by High –Performance Liquid Chromatography
...Show More Authors

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was tested by measuring average recovery values ranged between 94% - 101 %. For standerd solution, and 93%-99% of honey bee samples.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 01 2021
Journal Name
Desalination And Water Treatment
Extraction model to remove antibiotics from aqueous solution by emulsion and Pickering emulsion liquid membrane
...Show More Authors

View Publication
Scopus (11)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Sat Nov 12 2016
Journal Name
International Journal Of Mechanical Engineering And Technology (ijmet)
PERFORMANCE OF TWO-WAY NESTING TECHNIQUES FOR SHALLOW WATER MODELS
...Show More Authors

A new two-way nesting technique is presented for a multiple nested-grid ocean modelling system. The new technique uses explicit center finite difference and leapfrog schemes to exchange information between the different subcomponents of the nested-grid system. The performance of the different nesting techniques is compared, using two independent nested-grid modelling systems. In this paper, a new nesting algorithm is described and some preliminary results are demonstrated. The validity of the nesting method is shown in some problems for the depth averaged of 2D linear shallow water equation.

Publication Date
Sun Dec 31 2000
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Phenol from Water by Adsorption
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Removal of Water Turbidity by Different Coagulants
...Show More Authors

During the last decade, there has been a concern about the relation between aluminum residuals in treated water and Alzheimer disease, and more interest has been considered on the development of natural coagulants. The present study aimed to investigate the efficiency of alum as a primary coagulant in conjunction with mallow, Arabic gum and okra as coagulant aids for the treatment of water samples containing synthetic turbidity of kaolin. Jar test experiments were carried out for initial raw water turbidities 100, 200 and 500 (NTU). The optimum doses of alum, mallow, Arabic gum and okra were 20, 2, 1 and 1 mg/L for100 NTU turbidity level, 35, 4, 2 and 3 mg/L , for 200NTU turbidity level and 50, 8, 10 and 8 mg/L for 500 NTU turbidity leve

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Plant Archives
The seasonal effect on the water bodies in Iraqi marshlands
...Show More Authors

Scopus (5)
Scopus
Publication Date
Mon Dec 25 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Cefixime Following Simple Diazotization and Coupling with ?-Naphthol
...Show More Authors

Cefixime (CFX) was treated with sodium nitrite and hydrochloric acid for diazotization reaction followed by coupling with ?-Naphthol in alkaline medium to form, a yellow colored azo dye compound which exhibits maximum absorption (?max) at 412 nm where the concentration of (CFX) was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. Beer’s law was obeyed in the concentration range of (1-20) ?g.mL-1 with a molar absorptivity of 34870.5 L.mol-1.cm-1. The limit of detection was found to be 0.1090 ?g.mL-1 and the Sandell's sensitivity value was 0.0130 ?g.cm-2. The proposed method could be successfully applied to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Evaluation of Electrolytes Disturbances in Iraqi Chronic Myeloid Leukemia Patients treated with Nilotinib with Monitoring of Response by FISH Study
...Show More Authors

Chronic myeloid leukemia (CML) is a myeloproliferative disorder characterized by the presence Philadelphia chromosome (Ph) which was created by a reciprocal translocation between chromosomes 9 and 22 (t [9;22] [q34;q11]. The approval of the 2nd generation TKI ( Nilotinib) takes the treatment of CML patients into new erea with more efficiency and mild to moderate adverse effects. This study was aimed at evaluation of molecular cytogenetic response by (FISH) for Nilotinib in Iraqi patients with assessment for electrolytes disturbances of Nilotinb by measuring a panel of electrolyte (Na+, K+, Ca++, PO4--- and Mg++) , where thirty Iraqi patients with CML who have resistance or no response to Imatinib treatment, attending to Baghdad Teaching Ho

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 17 2019
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Chlorpromazine Hydrochloride Using 4-Nitroanilline by Oxidative Coupling Reaction
...Show More Authors

A simple, rapid spectrophotometric method has been established for the determination of chlorpromazine hydrochloride (CPZ) in its pure form and in a tablet formulations. The  suggested  method  is  based  on  the  oxidative coupling  reaction  with4-nitroainlline using KIO3 in acidic solution to produce a violet colored product with maximum absorption at λ=526 nm.The  analytical data  obtained  throughout  this  study  could  be  summarid  as  follows:  1ml of 1M HCl (pH=2.2), 1 ml  of  4-nitroanilline (1x10-2M), and 1.5ml  of (1x10-2)KIO3 per 25 ml reaction medium. The order of a

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Jan 25 2023
Journal Name
International Journal Of Biomaterials
Surface Characterization of Stainless Steel 316L Coated with Various Nanoparticle Types
...Show More Authors

Background. Material tribology has widely expanded in scope and depth and is extended from the mechanical field to the biomedical field. The present study aimed to characterize the nanocoating of highly pure (99.9%) niobium (Nb), tantalum (Ta), and vanadium (V) deposited on 316L stainless steel (SS) substrates which considered the most widely used alloys in the manufacturing of SS orthodontic components. To date, the coating of SS orthodontic archwires with Nb, Ta, and V using a plasma sputtering method has never been reported. Nanodeposition was performed using a DC plasma sputtering system with three different sputtering times (1, 2, and 3 hours). Results. Structural and elemental analyses were conducted on the deposited coating

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
New Method for the Determination of DL-Histidine by FIA and Chemiluminometric Detection
...Show More Authors

This paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.

View Publication Preview PDF
Crossref