Preferred Language
Articles
/
bsj-2422
Synthesis New Liquid Selective Electrodes of Ciprofloxacin Hydrochloride for Determination Ciprofloxacin in Pure form and Pharmaceuticals Preparation.
...Show More Authors

New membrane electrodes for determination of ciprofloxacin hydrochloride were prepared depending on ciprofloxacin hydrochloride - phosphotungstic acid (CFH-PT) as an active material and these electrodes were made with three plasticizers: Di-octylphenylphosphonate(DOPH), Di-butyl phosphate (DBP)Tri-n-butyl phosphate(TBP), in PVC matrix. One of the ciprofloxacin electrodes was gave Nernstian slope equal to 57.21 mV/ decade for DOPH membrane with concentration range from 1.5×10-5 to1.0×10-1 M, and detection limit equal to 1.5×10-6 M .Lifetime was 93 days. Non- Nernstian responses equal to 39.40 and 30.70 mV/ decade for membranes DBP, TBP, respectively. These electrodes were gave concentration range from 1.0× 10-5 to 1.0×10-2 and from 4.0×10-5 to 1.0×10-2 M,respectively. Detection limits were 7.0×10-6, and 1.7×10-6M, respectively. Lifetimes were 5,2 days, respectively. Also selectivity, influence of PH and samples analysis of ciprofloxacin in a pharmaceutical preparations were studied.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Engineering
Investigation of Factors Influencing Dispersion of Liquid Hydrocarbons in Porous Media
...Show More Authors

An experimental work has been done to study the major factors that affect the axial dispersion of some hydrocarbons during liquid-liquid miscible displacement. Kerosene and gas oil are used as displacing phase while seven liquid hydrocarbons of high purity represent the displaced phase, three of the liquids are aromatics and the rest are of paraffinic base. In conducting the experiments, two packed beds of different porosity and permeability are used as porous media.

The results showed that the displacement process is not a piston flow, breakthrough of displacing fluids are shown before one pore volume has been injected. The processes are stable with no evidence of viscous fingering.

Dispersion model as a

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 17 2016
Journal Name
Al-academy
Encrypted form and content in contemporary designs fabrics and aesthetic implications: زينب عبد علي محسن الزبيدي
...Show More Authors

This research was dealing with the aesthetic impact of encryption in form and content and aesthetic implications in the design of contemporary fabrics. That's where the design of the cloth is linked to the continuous development and continuous innovation and the pursuit of the all-new innovative designs and at the same time an unmarked Cryptographic with semantics and symbols reflect reality aesthetically pleasing and contains four chapters on the research :The first chapter discusses the research problem and its significance is the current quest ( encryption in form and content in contemporary designs fabrics and aesthetic implications ) in that it shows the importance of encryption in the design of fabrics and foundation design configu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Core-polarization effect in longitudinal electron scattering form factors of 65Cu nucleus
...Show More Authors

Inelastic longitudinal electron scattering form factors to 2+ and 4+ states in 65Cu nucleus has been calculated in the (2p3/2 1f 5/2 2p1/2) shell model space with the F5PVH effective interaction. The harmonic oscillator potential has been applied to calculate the wave functions of radial single-particle matrix elements. Two shell model codes, CP and NUSHELL are used to obtain results. The form factor of inelastic electron scattering to 1/21−, 1/22−, 3/22−, 3/23−, 5/21−, 5/22− and 7/2- states and finding the transition probabilities B (C2) (in units of e2 fm4) for these transitions and B (C4) (in units of e2 fm8) for the transition 7/2-, and comparing them with experimental data. Both the form factors and reduced transition pr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Applied Spectroscopy
Spectrophotometric Method for the Determination of Naphazoline Nitrate in Bulk and Pharmaceutical Preparations by Using 1,2-Naphthoquinone-4-Sulfonate
...Show More Authors

A simple, accurate, and cost-efficient UV-Visible spectrophotometric method has been developed for the determination of naphazoline nitrate (NPZ) in pure and pharmaceutical formulations. The suggested method was based on the nucleophilic substitution reaction of NPZ with 1,2-naphthoquinone-4-sulfonate sodium salt in alkaline medium at 80°C to form an orange/red-colored product of maximum absorption (λmax) at 483 nm. The stoichiometry of the reaction was determined via Job's method and limiting logarithmic method, and the mechanism of the reaction was postulated. Under the optimal conditions of the reaction, Beerʼs law was obeyed within the concentration range 0.5–50 μg/mL, the molar absorptivity value (ε) was 5766.5 L × mol–1 × c

... Show More
Scopus (1)
Scopus
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Applied Spectroscopy
Spectrophotometric Method for the Determination of Naphazoline Nitrate in Bulk and Pharmaceutical Preparations by Using 1,2-Naphthoquinone-4-Sulfonate
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Sep 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of-Copper Ions-from Aqueous Solution Using Liquid-Surfactant-Membrane Technique
...Show More Authors

Extraction of copper (Cu) from aqueous solution utilizing Liquid Membrane technology (LM) is more effective than precipitation method that forms sludge and must be disposed of in landfills. In this work, we have formulated a liquid surfactant membrane (LSM) that uses kerosene oil as the main diluent of LSM to remove copper ions from the aqueous waste solution through di- (2-ethylhexyl) phosphoric acid - D2EHPA- as a carrier. This technique displays several advantages including one-stage extraction and stripping process, simple operation, low energy requirement, and. In this study, the LSM process was used to transport Cu (II) ions from the feed phase to the stripping phase, which was prepared, using H2SO4. For LSM p

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Wed Oct 02 2019
Journal Name
Biochem. Cell. Arch.
NEW MIXED LIGAND OF DITHIOCARBAMATE AND 8- HYDROXYQUINOLINE WITH SOME COMPLEXES OF SCHIFF BASE LIGAND : SYNTHESIS, SPECTRAL ANALYSIS AND BIOLOGICAL ACTIVITY
...Show More Authors

The preparation, spectroscopic characterisation of complexes derived from the mixed ligands with CdII, ZnII and CoII metal ions with Schiff base, Dithiocarbamates (DTCs) and 8-Hydroxyquinoline are reported. The compounds that prepared have been defined via; chloride content, F.T-IR, UV-Vis 1H-NMR spectroscopy and C.H.N.S, as well as conductance and magnetic susceptibility.All data which collected from such methods specified complexes with 6 coordinates in solution and solid states. The biologicalactivity that is related to all the prepared compounds which were screened for their antimicrobial activitiesagainst (G+ and (G- )). The data that collected from biological activity indicate that complexes will have extra activity against such teste

... Show More
Publication Date
Sat Mar 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Preparation, Characterization, and Properties of Barium Titanate
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Aug 01 2019
Journal Name
Ieee Internet Of Things Journal
A New Task Allocation Protocol for Extending Stability and Operational Periods in Internet of Things
...Show More Authors

Scopus (20)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Tue Jan 09 2018
Journal Name
World Rural Observations
Solid cartridges in Determination of Benzidines in River and Wastewater by HPLC
...Show More Authors

A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS

... Show More