A rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium is studied. The method is based on the interaction of chromium with indigo carmine dye in acidic medium and the presence of oxalates as a catalyst for interaction, and after studying the absorption spectrum of the solution resulting observed decrease in the intensity of the absorption. As happened (Bleaching) for color dye, this palace and directly proportional to the chromium (VI) amount was measured intensity of the absorption versus solution was figurehead at a wavelength of 610 nm. A plot of absorbance with chromium (VI) concentration gives a straight line indicating that Beer’s law has been obeyed over the range of 0.5 -70 µg /25 ml, i.e., 0.02- 2.8 ppm with a molar absorptivity of chromium (VI) 1.71? 104 l.mol-1.cm-1, Sandell’s sensitivity index of 0.0030 µg.cm-2 .The detection limit of chromium was (DL) 0.0012 µg.mL-1 and a relative standard deviation of ? (0.70 -1.86)% depended on the concentration level. The method is developed for the determination of chromium(III) and has been successfully applied to the determination of chromium in various water samples, Pharmaceutical preparations ,standard rock sample of (MRG-1).
Ferns are considered as important medical herbs. They produce a wide range of secondary metabolites that could be useful in treating different diseases. However, they still remain underexplored in medical aspects in Iraq. Hence, the purpose of this study was to identify alkaloids components in the methanol extracts of four fern species (Asplenium ceterach L., A. scolopendrium L., Cheilanthes pteridioides (Richard) C. Chr. from Malakan region in Erbil Governorate and Equisetum ramosissimum Desf. from Chemi Rezan in Sulaimaniyah Governorate, of northen Iraq during March - June 2018. The research was conducted by using High performance liquid chromatography (H
... Show MoreTwo simple methods spectrophotometric were suggested for the determination of Cefixime (CFX) in pure form and pharmaceutical preparation. The first method is based without cloud point (CPE) on diazotization of the Cefixime drug by sodium nitrite at 5Cº followed by coupling with ortho nitro phenol in basic medium to form orange colour. The product was stabilized and measured 400 nm. Beer’s law was obeyed in the concentration range of (10-160) μg∙mL-1 Sandell’s sensitivity was 0.0888μg∙cm-1, the detection limit was 0.07896μg∙mL-1, and the limit of Quantitation was 0.085389μg∙mL-1.The second method was cloud point extraction (CPE) with using Trtion X-114 as surfactant. Beer
... Show MoreThis study focuses on CFD analysis in the field of the shell and double concentric tube heat exchanger. A commercial CFD package was used to resolve the flow and temperature fields inside the shell and tubes of the heat exchanger used. Simulations by CFD are performed for the single shell and double concentric tube.
This heat exchanger included 16 tubes and 20 baffles. The shell had a length of 1.18 m and its diameter was 220 mm. Solid Works 2014, ANSYS 15.0 software was used to analyze the fields of flow and temperature inside the shell and the tubes. The RNG k-ε model was used and it provided good results. Coarse and fine meshes were investigated, showing that aspect ratio has no significant effect. 14 million
... Show MoreFurosemide drug determination in pharmaceutical and biological urine samples using a novel continuous flow-injection analysis technique that is simple, rapid, sensitive and economical. The complex formed by the reaction of furosemide and O-phenylenediamine with oxidative agent K3[Fe(CN)6] to produce an orange-yellow colored product at 460 nm was the basis for the proposed method. The proposed method’s linearity ranges (3-100) μg.mL-1and (1-50) μg.mL-1 for CFIA/merging zone methods and batch .The detection limit and Limit of quantification values were 2.7502 μg.mL-1 and 9.1697 μg.mL-1 the relative standard deviation was 0.7143 %, and the average recovery is 98.80%
... Show MoreThis aim of this study is to assess the Tigris River sediments and utilize them as a new abrasive for the preparation of polished surface of magnetite ore to be studied under reflected light ore microscope. Such polishing process was tested using 250, 125, 71, 45, 25 and 18μm grain sizes of the river sediments. For the completion of the polishing and to obtain a glossy perfect polished surface, the 7 and 2.5 μm sized standard diamond pastes were used. After each polishing stage, the reflectance and roughness of these surfaces were measured as an evaluation step for the polishing efficiency. The reflectance values (R%) of the magnetite surface were found to be reversely proportioned to the abrasive grain size; while the surface roughnes
... Show MoreThe objective of this study was to investigate and compare among five different methods of contraception including combined oral contraceptive pills (COC), Depot medroxyprogesterone acetate (DMPA), copper Intrauterine contraceptive device (IUCD), vaginal spermicides and male condom used in Hawler City through estimate of their effect, relative failure rate, percentage of use, adherence and compliance and adverse effects of each contraceptive method. In order to reach to these aims, a retrospective study was conducted in Hawler City in Azadi Health Care Center over a period of 6 months from 22th November, 2010 to 15th May, 2011 during which data collection and subjects follow up for 3 months had been achieved. A conv
... Show MoreSKF Sami I. Jafar, Mohammad J. Kadhim, Engineering and Technology Journal, 2018 - Cited by 4