those affected by technological development risks within the scope of medical works. The unprecedented technological development the world witnesses nowadays has been providing brilliant medical service to the human being including examination, diagnosis and the treatment or follow up. However, such works hide behind potential risks threatening people's lives and such risks my be discovered within the limits of now – how and technical knowledge prevailing the time of rendering the medical service. Also this the question is raised on how to keep up between the safety of the patients and such risks are being unknown by the provider and questioning them contradicts the justices. subsequently, can the patients (affected) acquire the compensat
... Show MoreThis study aims to show the effectiveness of immobilization of Chlorella green algae biomass in the form of bead for the removal of lead ions from synthetic polluted water at various operational parameters such as pH (2–6), biosorbent dosage (0.5–20 g/L) and initial concentration (10–100 mg/L). More than 90 % removal efficiency was achieved. FTIR and SEM-EDX analysis of the biosorbent before and after sorption show differences in the functional groups on the adsorbent surface. Langmuir and Freundlich equilibrium isotherm, pseudo-first-order and pseudo-second-order kinetic models were applied to the experimental and results and show good conformity with Langmuir isotherm model and pseudo-second-order kinetic model with c
... Show MoreThis paper aims to study the second-order geometric nonlinearity effects of P-Delta on the dynamic response of tall reinforced concrete buildings due to a wide range of earthquake ground motion forces, including minor earthquake up to moderate and strong earthquakes. The frequency domain dynamic analysis procedure was used for response assessment. Reinforced concrete building models with different heights up to 50 stories were analyzed. The finite element software ETABS (version 16.0.3) was used to analyze reinforced concrete building models.
The study reveals that the percentage increase in buildings' sway and drift due to P-Delta effects are nearly constant for specific building height irrespective of the seism
... Show MoreThe performance of a solar assisted desiccant cooling system for a meeting-hall located in the College of Engineering/University of Baghdad was evaluated theoretically. The system was composed of four components; a solar air heater, a desiccant dehumidifier, a heat exchanger and an evaporative cooler. A computer simulation was developed by using MATLAB to assess the effect of various design and operating conditions on the performance of the system and its components. The actual weather data on recommended days were used to assess the load variation and the system performance during those days. The radiant time series method (RTS) was used to evaluate the hourly variation of the cooling load. Four operation modes were employed for perform
... Show MoreBackground: Cardiovascular disease (CVD) is the number one cause of death worldwide. Objective: To determine of coronary care unit nurses' knowledge regarding patient rehabilitation after myocardial infarction. Methodology: A cross- sectional study was designed in the Cardiac Care Unit of Al-Diwaniyah Teaching Hospital and the Specialized Center for Cardiac Surgery and Catheterization for the period from (November 7, 2022) to (May 12, 2023). A non-probability (purposive) sample consisting of (75 nurses) working in the above-mentioned study site. To determination of coronary care unit Nurses' knowledge regarding patient rehabilitation after myocardial infarction, the researcher used a tool that consists of two parts: The first part:
... Show MoreTin dioxide (SnO2) were mixed with (TiO2 and CuO) with concentration ratio (50, 60, 70, 80 and 90) wt% films deposited on single crystal Si and glass substrates at (523 K) by spray pyrolysis technique from aqueous solutions containing tin (II) dichloride Dihydrate (SnCl2, 2H2O), dehydrate copper chloride (CuCl2.2H2O) and Titanium(III) chloride (TiCl3) with molarities (0.2 M). The results of electrical properties and analysis of gas sensing properties of films are presented in this report. Hall measurement showed that films were n-type converted to p- type as titanium and copper oxide added at (50) % ratio. The D.C conductivity measurements referred that there are two mechanisms responsible about the conductivity, hence it possess two act
... Show More