Preferred Language
Articles
/
bijps-367
Bioequivalence and Pharmacokinetics Comparison of Two Formulations of Extended-Release Pentoxifylline Tablets in Healthy Subjects after Fasting and Fed Conditions
...Show More Authors

The pharmacokinetics and bioequivalence of a newly developed extended-released (ER) tablet containing 400 mg pentoxifylline as a test product was compared with the reference brand product Trental® 400 mg ER tablet produced by Sanofi-Aventis. Two separate studies were conducted simultaneously. The first study was conducted under fasting condition, whereas, the second study was conducted under fed condition; using the same batches of the test and reference products in both studies. In each study, both products were administered to 32 healthy male adult volunteers applying a single-dose, two-treatment, two-period, two-sequence, randomized crossover design with one-week washout period between dosing. Twenty two blood samples were withdrawn from each volunteer over 24 hours period.  Pentoxifylline concentrations were determined in plasma by a validated HPLC method according to FDA Bioanalytical Method Validation Guidance using UV detection and chloramphenicol as internal standard. The lower limit of quantitation of the drug in plasma was 5 ng/ml and the upper limit of quantitation was 500 ng/ml. From the plasma concentration-time data of each individual, the pharmacokinetic parameters; Cmax,  AUC0-t, AUC0-Â¥, Cmax/AUC0-Â¥, Tmax, lZ & T0.5; were calculated applying non-compartmental analysis. Data of the test and reference products were statistically analyzed to test for bioequivalence of the two products, using criteria of FDA and EMEA Guidance.  The pharmacokinetic parameters mentioned above were statistically analyzed by descriptive statistics, ANOVA test and 90% Confidence Interval (CI). ANOVA test involved the calculation of the effects of: treatment, period, sequence and subjects nested in sequence. According to the above guidance, the primary pharmacokinetic parameters used for bioequivalence testing, namely Cmax, AUC0-t and AUC0-Â¥ were also statistically analyzed by ANOVA & CI tests using the corresponding Ln-transformed values. The mean values  Cmax,  AUC0-t , AUC0-Â¥ , Cmax/AUC0-Â¥ , Tmax, lZ & T0.5 for the test formula obtained from the fasting study  were; 144.4 ng/ml,  845.4 ng.hr/ml, 868.4 ng.hr/ml, 0.186 hr-1, 3.29 hr, 0.561 hr-1 and 1.65 hr, respectively; and the mean values of these parameters for the reference formula were; 150.0 ng/ml,  871.1 ng.hr/ml, 893.7 ng.hr/ml, 0.177 hr-1, 3.70 hr, 0.558 hr-1 and 1.59 hr,  respectively.  The mean values of the above mentioned parameters for the test formula obtained from the fed study were; 157.8 ng/ml, 826.5 ng.hr/ml, 853.8 ng.hr/ml, 0.198 hr-1, 5.4 hr, 0.458 hr-1 and 2.06 hr, respectively; and the mean values of these parameters for the reference formula were; 162.1 ng/ml, 869.7 ng.hr/ml, 894.8 ng.hr/ml, 0.196 hr-1, 4.1 hr, 0.525 hr-1 and 1.80 hr, respectively.  Based on criteria of FDA and   EMEA Guidance on Bioavailability and Bioequivalence, the results of the fasting and fed studies demonstrated bioequivalence of the two products under either condition. Accordingly, it is concluded that the newly developed ER tablet containing 400 mg pentoxifylline is bioequivalent to Trental® 400 mg ER tablet produced by Sanofi-Aventis.

Keywords: Pentoxifylline, Pharmacokinetics, Bioequivalence.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 31 2019
Journal Name
Journal Of Engineering And Applied Sciences
Comparison of Estimate Methods of Multiple Linear Regression Model with Auto-Correlated Errors when the Error Distributed with General Logistic
...Show More Authors

In this research, we studied the multiple linear regression models for two variables in the presence of the autocorrelation problem for the error term observations and when the error is distributed with general logistic distribution. The auto regression model is involved in the studying and analyzing of the relationship between the variables, and through this relationship, the forecasting is completed with the variables as values. A simulation technique is used for comparison methods depending

Scopus (1)
Scopus Crossref
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Phenomena of corruption and money laundering: and causes and risks and their role in the financing of terrorism in Iraq and finding ways of treatment
...Show More Authors

Iraq  is Suffering nowadays from the criminal triad represented by the fiscal and administrative corruption, money laundering and terrorism, which are intertwined in a very related relations, as each of them support the other . Since the over growth has been one of its characteristics leaving behind a very dangerous negative effects whether it was social , economic or even political impacts . As a result , this trial is now represents a high risk that threatens the present and the future of Iraq . On the political , economic and social level , it is well to mention that the poor direct investment , the increasing rates of poverty , unemployment , inflation as well as the smuggling of goreign currency an

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2022
Journal Name
Iraqi Journal Of Physics
Effects of Hydrogen Peroxide Concentration on Properties of Black Silicon Fabricated by Two-Step Silver-Assisted Wet Chemical Etching for Photovoltaics
...Show More Authors

Crystalline silicon (c-Si) has low optical absorption due to its high surface reflection of incident light. Nanotexturing of c-Si which produces black silicon (b-Si) offers a promising solution. In this work, effect of H2O2 concentrations towards surface morphological and optical properties of b-Si fabricated by two-step silver-assisted wet chemical etching (Ag-based two-step MACE) for potential photovoltaic (PV) applications is presented. The method involves a 30 s deposition of silver nanoparticles (Ag NPs) in an aqueous solution of AgNO3:HF (5:6) and an optimized etching in HF:H2O2:DI H2O solution under 0.62 M, 1.85 M, 2.47 M, and 3.7 M concentrations of H2O<

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Nov 05 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Effect of Mechanical Surface Treatment on the Tensile Bond Strength of Repaired Acrylic Denture Base Resin Cured by Two Different Techniques
...Show More Authors

Objective: To evaluate and compare the effect of mechanical surface treatment (groove, aluminum oxide particles)
with 45 degree bevel type of joint on tensile bond strength of acrylic specimens repaired by two curing methods
(microwave and water both).
Methodology: Eighty specimens (80) were prepared from pink heat cure acrylic resin. They were divided into two
main groups (40 specimen repaired by microwave energy and 40 specimens repaired by water bath method).Each
group can be divided into four subgroups of ten according to the surface treatment. The control group A was left
intact, group B received no surface treatment, group C and D received surface treatment by (groove, 50 m aluminum
oxide particles). Specimens

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Under Different Priors &Two Loss Functions To Compare Bayes Estimators With Some of Classical Estimators For the Parameter of Exponential Distribution
...Show More Authors

المستخلص:

          في هذا البحث , استعملنا طرائق مختلفة لتقدير معلمة القياس للتوزيع الاسي كمقدر الإمكان الأعظم ومقدر العزوم ومقدر بيز في ستة أنواع مختلفة عندما يكون التوزيع الأولي لمعلمة القياس : توزيع لافي  (Levy) وتوزيع كامبل من النوع الثاني وتوزيع معكوس مربع كاي وتوزيع معكوس كاما وتوزيع غير الملائم (Improper) وتوزيع

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
A Comparison of Parameters Estimation Methods for the Negative Binomial Regression Model under Multicollinearity Problem by Using Simulation
...Show More Authors

This study discussed a biased estimator of the Negative Binomial Regression model known as (Liu Estimator), This estimate was used to reduce variance and overcome the problem Multicollinearity between explanatory variables, Some estimates were used such as Ridge Regression and Maximum Likelihood Estimators, This research aims at the theoretical comparisons between the new estimator (Liu Estimator) and the estimators

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 31 2018
Journal Name
International Journal Of Research In Pharmaceutical Sciences
The impact of systemic hypertension-related heart remodeling on right ventricle mechanics: A two-dimensional echocardiographic speckle tracking study
...Show More Authors

Scopus
Publication Date
Thu Jun 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Compared of estimating two methods for nonparametric function to cluster data for the white blood cells to leukemia patients
...Show More Authors

 

Abstract:                                        

   We can notice cluster data in social, health and behavioral sciences, so this type of data have a link between its observations and we can express these clusters through the relationship between measurements on units within the same group.

    In this research, I estimate the reliability function of cluster function by using the seemingly unrelate

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Crystallization firing effect on the marginal discrepancy of the IPS. emax CAD crowns using two different CAD/CAM systems
...Show More Authors

Background: Marginal adaptation is critical for long – term success of crown and bridge restoration. Computer aided design / computer aided manufacture (CAD/ CAM) system is gaining more importance in the fabrication of dental restoration. Objective: The aim of this study is to evaluate the effect of crystallization firing on the vertical marginal gap of IPS. emax CAD crowns which fabricated with two different CAD/CAM systems .Materials and Methods: Twenty IPS e.max CAD crowns were fabricated. We had two major groups (A, B) (10 crowns for each group) according to the CAD/CAM system being used: Group A: fabricated with Imes - Icore CAD/CAM system; Group B: fabricated with In Lab Sirona CAD/CAM system. Each group was subdivided into two s

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Physics: Conference Series
The effect of left ventricle ischemia severity on cardiac performance appeared on ejection fraction using radioactive TC <sup>99m</sup> MIBI in comparison with echocardiography
...Show More Authors
Abstract<p>Ischemic heart disease is a major causes of heart failure. Heart failure patients have predominantly left ventricular dysfunction (systolic or diastolic dysfunction, or both). Acute heart failure is most commonly caused by reduced myocardial contractility, and increased LV stiffness. We performed echocardiography and gated SPECT with Tc<sup>99m</sup> MIBI within 263 patients and 166 normal individuals. Left ventricular end systolic volume (LVESV), left ventricular end diastolic volume (LVEDV), and left ventricular ejection fraction (LVEF) were measured. For all degrees of ischemia, there was a significant difference between ejection fraction values measured by SPECT and echo</p> ... Show More
View Publication
Scopus Crossref