Preferred Language
Articles
/
alkej-596
Mass-Transfer Characteristics of Air- Suction Type Fermentors
...Show More Authors

Liquid-side mass-transfer coefficients (KLa) were measured in air-suction type fermentors using physical absorption of oxygen.  A fermentor of 0. 5 m i.d. was used with a working capacity of 60 liters of liquid. Tap water was used as the liquid phase, and air was used as the gas phase. The bioreactor mixing system consists of shrouded-disk/curved-blade turbine with six evacuated bending blades. The effect of liquid submergence (S) was investigated. Further, the effects of the ratio of the impeller diameter (D) to the tank diameter (T), and the clearance of the impeller from the tank bottom(C) were also studied.  The agitation speed (N) was varied in the range of 50-800 rpm. It was found that the value of  KLa increased as the impeller diameter  increased, while it was decreased continuously with increasing the clearance. the effect of impeller submergence on the value of mass transfer coefficient (KLa) is not much pronounced.

Suitable correlation was developed for estimating mass transfer coefficient (KLa) in this type of bioreactors.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 31 2020
Journal Name
International Journal Of Heat And Technology
Enhancement of Natural Convection Heat Transfer of Hybrid Design Heat Sink
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Sep 02 2015
Journal Name
Lap Lambert Academic Publishing
The role of tibialis posterior transfer in correction of foot drop
...Show More Authors

View Publication Preview PDF
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Numerical Study Of Heat Transfer In Cooling Passages Of Turbine Blade
...Show More Authors

As the temperature of combustion gases is higher than the melting temperature of the turbine materials, cooling of turbine parts in a gas turbine engine is necessary for safe operation. Cooling methods investigated in this computational study included cooling flow losses. Film-cooling is one typically used cooling method whereby coolant is supplied through holes passage, in present study the holes placed along the camber line of the blade. The subject of this paper is to evaluate the heat transfer that occur on the holes of blade through different
blowing coolant rates. The cases of this study were performed in a low speed wind tunnel with two tip gap at small and large (0.03 and 0.09cm) and multiple coolant flow rates through the fil

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Probability Concepts of Transfer Load to the Foundation of Container Structure
...Show More Authors

This paper presents stochastic analysis using the perturbation method to model the structure of a container to verify the distributions of probability of maximum and minimum axial forces reactions in piles. The proposed simulation of a container port terminal under 11 scenarios of load combinations was presented. The probability distributions for live loads are assigned according to the input parameters of simulation data. Part of the load itself is implicitly combined such as vertical live load which includes the weight of equipment and containers and wind load. The structural model was simulated in the software STAAD Pro., while the statistical analyses were performed with MATLAB. The results demonstrated that, the most significant extern

... Show More
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Caspian Journal Of Environmental Sciences
Assessment of indoor air quality for closed cafés in Baghdad City, Iraq
...Show More Authors

The phenomenon of young people frequenting closed cafes spread in Baghdad to smoke hookahs and cigarettes has increased. This phenomenon is associated with unemployment, an increase in leisure time and the deterioration of economic conditions. This phenomenon has an impact on indoor air quality and exposes workers to the risk of exposure to various pollutants, including particulate matter, therefore, we examined some indicators (PM2.5, PM10) IAQ for a month in summer and another month in winter in six different locations in the Rusafa district. PM2.5 and PM10 concentrations, relative humidity (RH) and temperatures were measured using (Multifunction Air Quality Detector BENETECH -China). The results showed an increase in temperatures inside

... Show More
View Publication Preview PDF
Publication Date
Fri May 18 2018
Journal Name
International Journal Of Advanced Biological Research
CALCULATION THE AIR POLLUTION TOLERANCE INDEX OF EUCALYPTUS PLANT IN BAGHDAD CITY
...Show More Authors

Air pollution from various sources is one of the most serious environmental problems, especially after pollutants are deposited on the surface of the soil and leaves of the plants and then transferred to the rest of the plant and entering food chains. The present study was conducted to determine the effects of air pollution on different biochemical parameters in Eucalyptus sp. and calculation the Air Pollution Tolerance Index. The selected plant leaves were collected from five sites, four of them within the city of Baghdad, namely Al-Jadriya, Al-Andlous, Al-Doura and close to the private generators to represent the urban areas and Abu Ghraib site to represent the rural area. The leaves were taken on a seasonal basis for the period from Octo

... Show More
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of Hybrid Solar Air Conditioning System using a New Control Strategy
...Show More Authors

Enhancement of the performance for hybrid solar air conditioning system was presented in this paper. The refrigerant temperature leaving the condenser was controlled using three-way valve, this valve was installed after the compressor to regulate refrigerant flow rate towards the solar system. A control system using data logger, sensors and computer was proposed to set the opening valve ratio. The function of control program using LabVIEW software is to obtain a minimum refrigerant temperature from the condenser outlet to enhance the overall COP of the unit by increasing the degree of subcooled refrigerant. A variable load electrical heater with coiled pipe was used instead of the solar collector and the storage tank to simulate the sola

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Journal Of The College Of Education For Women
Effect of some air pollutants (sticking minutes and lead) on human health
...Show More Authors

Air pollution is one of the complex problems plaguing the environment at the present time
as a result of many liberation of gases, vapors and fumes of fuels and chemicals resulting
from industrial activities . It should be noted that there are some elements of the heavy (Heavy
Metals), including toxic in the air, with different concentrations in the air depending on the
nature of the area, for example be in rural areas is lower than in cities or industrial areas as
measured parts million (ppm ) or parts per billion (ppb). Some of these important elements in
the physiological processes and enzymatic organisms but become toxic and Qatlhand-increase
Tercisahaan the permissible limits Bhave nature ,The air contaminant co

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Craniofacial Surgery
The Impact of Blast Implosions and Bullet Injury on Maxillary Air Sinus
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Jan 30 2019
Journal Name
Journal Of The College Of Education For Women
Effect of some air pollutants (sticking minutes and lead) on human health
...Show More Authors

Air pollution is one of the complex problems plaguing the environment at the present time
as a result of many liberation of gases, vapors and fumes of fuels and chemicals resulting
from industrial activities . It should be noted that there are some elements of the heavy
(Heavy Metals), including toxic in the air, with different concentrations in the air depending
on the nature of the area, for example be in rural areas is lower than in cities or industrial
areas as measured parts million (ppm ) or parts per billion (ppb). Some of these important
elements in the physiological processes and enzymatic organisms but become toxic and
Qatlhand-increase Tercisahaan the permissible limits Bhave nature ,The air contaminant

... Show More
View Publication Preview PDF