Preferred Language
Articles
/
alkej-441
The Computational Fluid Dynamic Simulations for Gangrene Disease in Diabetic Foot
...Show More Authors

The diabetic foot is considered one of the long term diabetes complications caused by a defect in blood vessel and nerve system. This requires dealing with diabetic foot with professional medical care, so as to prevent its development in advanced stages which could end to gangrene and amputation of the foot. This study has been initiated through follow-up of twelve patients with diabetes and the presence various occlusions in lower limb artery. One patient from them was chosen for investigation, this patient has stenosis in popliteal artery and presence multiple stenosis in superficial femoral artery. This study based on analysis present case of patient and prediction for progress stenosis in superficial femoral artery till arrive semi total occlusion of the artery and interpret the occurrence of gangrene in the lower limb. The geometrical values of the artery and stenosis were acquired measured directly from the patient by using angiography device. The disease of gangrene and artery stenosis in diabetic foot has been investigated by using a simulation program (ANSYS Fluent CFD).  The results of study by using four models with (75%, 90%) stenosis from original artery diameter in the healthy patient case are presented and compared with present and healthy case (without stenosis). It has been appeared, with presence of multi stenosis in superficial femoral artery for diabetic foot, and by assuming the blood to be a Newtonian fluid, a significant increase in the blood velocity and wall shear stress in the area of stenosis compared with non stenosis region. The blood flow rate was decreased constrained as the degree of stenosis increased and vice versa. Peak blood velocity is about (0.88) m/sec for healthy artery, it reaches (2) m/sec for a 42.4% stenosis (current case).The maximum velocity values were (10.36, 49.31) m/sec for 75%, 90% stenosis respectively. The maximum wall shear stress at the stenosis region varies from (1094) pa in the 75% stenosis to (15916) pa in the 90% stenosis against a values of (6.36, 380.5) pa in the healthy artery, current case respectively.                                    

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Aug 01 2016
Journal Name
2016 38th Annual International Conference Of The Ieee Engineering In Medicine And Biology Society (embc)
Changes in the EEG amplitude as a biomarker for early detection of Alzheimer's disease
...Show More Authors

The rapid increase in the number of older people with Alzheimer's disease (AD) and other forms of dementia represents one of the major challenges to the health and social care systems. Early detection of AD makes it possible for patients to access appropriate services and to benefit from new treatments and therapies, as and when they become available. The onset of AD starts many years before the clinical symptoms become clear. A biomarker that can measure the brain changes in this period would be useful for early diagnosis of AD. Potentially, the electroencephalogram (EEG) can play a valuable role in early detection of AD. Damage in the brain due to AD leads to changes in the information processing activity of the brain and the EEG which ca

... Show More
View Publication
Scopus (23)
Crossref (11)
Scopus Crossref
Publication Date
Mon Sep 16 2019
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Peristaltic Flow of the Bingham Plastic Fluid in a Curved Channel
...Show More Authors

    In this paper, we study the peristaltic transport of incompressible Bingham plastic fluid in a curved channel. The formulation of the problem is presented through, the regular perturbation technique for small values of  is used to find the final expression of stream function. The numerical solution of pressure rise per wave length is obtained through numerical integration because its analytical solution is impossible. Also the trapping phenomenon is analyzed. The effect of the variation of the physical parameters of the problem are discussed and illustrated graphically.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Baghdad Science Journal
Collection, Storage and Protein Extraction Method of Gingival Crevicular Fluid for Proteomic Analysis
...Show More Authors

Gingival crevicular fluid (GCF) may reflect the events associated with orthodontic tooth movement. Attempts have been conducted to identify biomarkers reflecting optimum orthodontic force, unwanted sequallea (i.e. root resorption) and accelerated tooth movement. The aim of the present study is to find out a standardized GCF collection, storage and total protein extraction method from apparently healthy gingival sites with orthodontics that is compatible with further high-throughput proteomics. Eighteen patients who required extractions of both maxillary first premolars were recruited in this study. These teeth were randomly assigned to either heavy (225g) or light force (25g), and their site specific GCF was collected at baseline and aft

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Sep 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Study in to the Dynamic Behavior of Packed Distillation Column
...Show More Authors

The study of the dynamic behavior of packed distillation column was studied by frequency response analysis using Matlab program. A packed distillation column (80 mm diameter) (2000 mm height) filled with glass packing (Raschig Rings 10mm), packing height (1500 mm) has been modified for separation of methanol-water mixture (60 vol%). The column dynamic behavior was studied experimentally under different step changes in, feed rate (±30%), reflux rate (±22%), and reboiler heat duty (±150%), the top and bottom concentration of methanol were measured. A frequency response analysis for the above step response was carried out using Bode diagram, the log modulus and the phase angle were  used to analyze the process model. A Matlab progra

... Show More
View Publication Preview PDF
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Mathematical Modelling for Peristaltic Flow of Sutterby Fluid Through Tube under the Effect of Endoscope
...Show More Authors

     In this work, the mathematical modelling of peristaltic transport for incompressible Sutterby fluid through the cavity between coaxial tubes where the inner tube is fixed and the outer tube has sinusoidal rhythmic fluctuations along the channel’s walls is presented. Under the assumption of long wavelength and the low Reynolds number, the governing equations (motion, temperature, and concentration) are illustrated in cylindrical coordinates. The analytical solution for the temperature and concentration of the fluid flow is obtained using Mathematica 11.3, whereas the perturbation technique is employed to find the closed form of the velocity profile. The variation of the axial velocity, stream function, temperat

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Mathematical Modelling Of Engineering Problems
Dynamic Low Power Clustering Strategy in MWSN
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Jan 11 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental Estimation of Critical Buckling Velocities for Conservative Pipes Conveying Fluid
...Show More Authors

Conservative pipes conveying fluid such as pinned-pinned (p-p), clamped–pinned (c-p) pipes and clamped-clamped (c-c) lose their stability by buckling at certain critical fluid velocities. In order to experimentally evaluate these velocities, high flow-rate pumps that demand complicated fluid circuits must be used.

     This paper studies a new experimental approach based on estimating the critical velocities from the measurement of several fundamental natural frequencies .In this approach low flow-rate pumps and simple fluid circuit can be used.

Experiments were carried out on two pipe models at three different boundary conditions. The results showed that the present approach is more accurate for est

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Left Ventricular Hypertrophy in Diabetic Patients and Its Relation to Other Diabetic Complications
...Show More Authors

Background: left ventricular hypertrophy is independent risk factor for cardiovascular morbidity and mortality. The presence of diabetic complications such as autonomic neuropathy and retinopathy may predict cardiac structural changes in diabetic patients. Objective: To explore the chance of occurrence of left ventricular hypertrophy in diabetic patients and whether it is related to the presence of other diabetic complications. Methods: ninty seven (97) normotensive diabetic patients (57) type II with mean duration of diabetes of (12±6 y) and forty (40) type I with mean duration of (8±6 y) were studied by echocardiography and compared with 41 patients as control. Results: The LVMI was significantly higher in type II diabetics compared

... Show More
View Publication Preview PDF
Publication Date
Sat Nov 28 2020
Journal Name
Iraqi Journal Of Science
Activation and Enhancement of the Performance of Iraqi Ca-Bentonite for Using as Drilling Fluid in Iraqi Oil Fields
...Show More Authors

In this study, Iraqi bentonite taken from Trefawi area/ Al-Anbar region province/ Iraq, was activated to enhance its rheological and filtration properties and increase its quality by decreasing the non-clay minerals (impurities), in order to be used in Iraqi oil companies instead of commercial bentonite. Bentonite was characterized by X-ray diffraction (XRD), X-ray fluorescence (XRF) and particle size distribution (PSD) before and after activation to show the effects on its mineral and chemical properties. The rheological properties of bentonite were enhanced by using different weights (0.4, 0.5, 0.6, 0.7 and 0.8 gm) of sodium carbonate (Na₂CO₃), whereas the filtration properties were enhanced by using different weights (0.5

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (5)
Scopus Crossref
Publication Date
Sat Dec 02 2017
Journal Name
Al-khwarizmi Engineering Journal
Free Vibration Analysis for Dynamic Stiffness Degradation of Cracked Cantilever Plate
...Show More Authors

 

In the present work a dynamic analysis technique have been developed to investigate and characterize the quantity of elastic module degradation of cracked cantilever plates due to presence of a defect such as surface of internal crack under free vibration. A new generalized technique represents the first step in developing a health monitoring system, the effects of such defects on the modal frequencies has been the main key quantifying the elasticity modulii due to presence any type of un-visible defect. In this paper the finite element method has been used to determine the free vibration characteristics for cracked cantilever plate (internal flaws), this present work achieved by different position of crack. Stiffness re

... Show More
View Publication Preview PDF