Preferred Language
Articles
/
alkej-441
The Computational Fluid Dynamic Simulations for Gangrene Disease in Diabetic Foot
...Show More Authors

The diabetic foot is considered one of the long term diabetes complications caused by a defect in blood vessel and nerve system. This requires dealing with diabetic foot with professional medical care, so as to prevent its development in advanced stages which could end to gangrene and amputation of the foot. This study has been initiated through follow-up of twelve patients with diabetes and the presence various occlusions in lower limb artery. One patient from them was chosen for investigation, this patient has stenosis in popliteal artery and presence multiple stenosis in superficial femoral artery. This study based on analysis present case of patient and prediction for progress stenosis in superficial femoral artery till arrive semi total occlusion of the artery and interpret the occurrence of gangrene in the lower limb. The geometrical values of the artery and stenosis were acquired measured directly from the patient by using angiography device. The disease of gangrene and artery stenosis in diabetic foot has been investigated by using a simulation program (ANSYS Fluent CFD).  The results of study by using four models with (75%, 90%) stenosis from original artery diameter in the healthy patient case are presented and compared with present and healthy case (without stenosis). It has been appeared, with presence of multi stenosis in superficial femoral artery for diabetic foot, and by assuming the blood to be a Newtonian fluid, a significant increase in the blood velocity and wall shear stress in the area of stenosis compared with non stenosis region. The blood flow rate was decreased constrained as the degree of stenosis increased and vice versa. Peak blood velocity is about (0.88) m/sec for healthy artery, it reaches (2) m/sec for a 42.4% stenosis (current case).The maximum velocity values were (10.36, 49.31) m/sec for 75%, 90% stenosis respectively. The maximum wall shear stress at the stenosis region varies from (1094) pa in the 75% stenosis to (15916) pa in the 90% stenosis against a values of (6.36, 380.5) pa in the healthy artery, current case respectively.                                    

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Aug 01 2014
Journal Name
Int. J. Mod. Eng. Res
Exact solutions for MHD flow of a viscoelastic fluid with the fractional Burgers’ model in an annular pipe
...Show More Authors

This paper presents an analytical study for the magnetohydrodynamic (MHD) flow of a generalized Burgers’ fluid in an annular pipe. Closed from solutions for velocity is obtained by using finite Hankel transform and discrete Laplace transform of the sequential fractional derivatives. Finally, the figures are plotted to show the effects of different parameters on the velocity profile.

View Publication
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
An Experimental Study of the Effects of Coolant Fluid on Surface Roughness in Turning Operation for Brass Alloy
...Show More Authors

The effect of different cutting fluids on surface roughness of brass alloy workpiece during turning operation was carried out in this research. This was performed with different cutting speed, while other cutting parameters had been regarded as constants(feeding rate , and depth of cut). Surface roughness of machined parts that will be tested by electronic surface roughness tester .The results show that the standard coolant gives the best values of surface roughness for fixed cutting speed ,followed by sun flower oil that has approximately the same effect, while the air stream as a coolant gave unsatisfied results for the evaluation of surface roughness.

In the other hand the best values of surface roughness were recorded for max

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed May 31 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
THE EFFECT OF ALCOHOLIC EXTRACT OF ANETHUM GRAVEOLENS IN ALLOXAN INDUCED DIABETIC RATS.: THE EFFECT OF ALCOHOLIC EXTRACT OF ANETHUM GRAVEOLENS IN ALLOXAN INDUCED DIABETIC RATS.
...Show More Authors

Active compounds were extracted from Anethum gravoelens to produce safety vegetable treat for diabetic, the results showed that alcoholic extract of Anethum gravoelens contain Alkaloid, glycosides, phenols, resins, saponins, coumarins, flavonoide, terpenes, steroids and volatile oils. after that it was studied the effect of alcoholic extract at dose 50, 100 mg/kg of body weight in reduced glucose level in serum of diabetic rats induced by alloxan, after the end of experiment for period 30 days the rats fasting 12 hours to measure the level of glucose in serum, the result showed asignificant decrease in serum glucose level of rats treated with extract in comparison with positive group (alloxan), So biochemical tests showed significant dec

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2013
Journal Name
J. Baghdad For Sci
Numerical Simulations of Imaging Extrasolar Planets using Circular and Square Apodize Apertures
...Show More Authors

Numerical simulations are carried out to assess the quality of the circular and square apodize apertures in observing extrasolar planets. The logarithmic scale of the normalized point spread function of these apertures showed sharp decline in the radial frequency components reaching to 10-36 and 10-34 respectively and demonstrating promising results. This decline is associated with an increase in the full width of the point spread function. A trade off must be done between this full width and the radial frequency components to overcome the problem of imaging extrasolar planets.

Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Science
Effects of the Rotation on the Mixed Convection Heat Transfer Analysis for the Peristaltic Transport of Viscoplastic Fluid in Asymmetric Channel
...Show More Authors

      In this paper, we study the impact of the variable rotation and different variable on mixed convection peristaltic flow of incompressible viscoplastic fluid. This is investigated in two dimensional asymmetric channel, such as the density, viscosity, rate flow, Grashof number, Bingham number, Brinkman number and tapered, on the mixed convection heat transfer analysis for the peristaltic transport of viscoplastic fluid with consideration small Reynolds number and long wavelength, peristaltic transport in asymmetric channel tapered horizontal channel and non-uniform boundary walls to possess different amplitude wave and phases. Perturbation technique is used to get series solutions. The effects of different values of these parame

... Show More
View Publication Preview PDF
Scopus (10)
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
International Journal Of Surgery Case Reports
Myositis ossificans: A rare location in the foot. Report of a case and review of literature
...Show More Authors

View Publication Preview PDF
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Computational Optimization of the Radial and Spiral Distortion Aberration Coefficients of Magnetic Deflector
...Show More Authors

Abstract:The optimum design of the magnetic deflector with the lowest values of the radial and spiral distortion aberration coefficients was computed. The optimized calculations were made using three models, Glaser bell-shaped, Grivet-lenz and exponential models. By using the optimum axial field distribution, the pole pieces shape which gave rise to those field distributions was found by using the reconstruction method. The calculations show that the results of the three models coincide at the lower values of the excitation parameter. In general the Glaser- bell shaped model gives the optimum results at the whole range of the excitation parameter under investigation.The negative values of the spiral distortion aberration coefficient appears

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Composite Structures
Computational homogenization of the elastic and thermal properties of superconducting composite MgB2 wire
...Show More Authors

View Publication
Scopus (39)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Open Biology
Structure and in silico simulations of a cold-active esterase reveals its prime cold-adaptation mechanism
...Show More Authors

Here we determined the structure of a cold active family IV esterase (EstN7) cloned from Bacillus cohnii strain N1. EstN7 is a dimer with a classical α/β hydrolase fold. It has an acidic surface that is thought to play a role in cold-adaption by retaining solvation under changed water solvent entropy at lower temperatures. The conformation of the functionally important cap region is significantly different to EstN7's closest relatives, forming a bridge-like structure with reduced helical content providing greater access to the active site through more than one substrate access tunnel. However, dynamics do not appear to play a major role in cold adaption. Molecular dyn

... Show More
View Publication
Scopus (13)
Scopus
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Cam Dynamic Synthesis
...Show More Authors

The paper presents an original method to make the geometric synthesis of the rotary cam and translated tappet with roll. Classical method uses to the geometric synthesis and the reduced tappet velocity, and in this mode the geometric classic method become a geometric and kinematic synthesis method. The new geometric synthesis method uses just the geometric parameters (without velocities), but one utilizes and a condition to realize at the tapped the velocities predicted by the tapped movement laws imposed by the cam profile. Then, it makes the dynamic analyze for the imposed cam profile, and one modify the cam profile geometric parameters to determine a good dynamic response (functionality). In this mode it realizes the dynamic synthesis

... Show More
View Publication Preview PDF