Preferred Language
Articles
/
_hZa1YgBVTCNdQwCyYIi
Comparism Between Transvaginal Cervical Length Measurement and Digital Examination in Prediction of Imminent preterm Delivery
...Show More Authors

BACKGROUND: Preterm labour is a major cause of perinatal morbidity and mortality, so it is important to predict preterm delivery using the clinical examination of the cervix and uterine contraction frequency. New markers for the prediction of preterm birth have been developed such as transvaginal ultrasound measurement of cervical length as this method is widely available. OBJECTIVE: To determine, whether transvaginal cervical length measurement predicts imminent preterm delivery better than digital cervical length measurement in women presented with preterm labour and intact membranes. PATIENTS AND METHODS: Two hundred women presented with preterm labour between 24 and 36+6 weeks of gestation were included in this study. All women subjected for digital and transvaginal ultrasound cervical length measurement and the outcome measures were occurrence of preterm delivery within 48 hours and within 7 days. RESULTS: Assessment of cervical length measurement using transvaginal ultrasound for the 200 women presented with preterm labour with intact membrane revealed that 8 (4%) delivered within 48 hours and 16 (8%) delivered within 7 days. According to the Bishop score, the test was positive if the Bishop score was ≥8, or 4-7 with cervical length ≤30 mm. The cut-off value for transvaginal ultrasound cervical length considered as 30 mm in the study group. CONCLUSION: Transvaginal sonographic measurement of cervical length can predict imminent preterm delivery in women presented with preterm uterine contractions and Bishop score between 4 - 7 compared with digital cervical length measurement.

View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
Effect of alteration in nutritional style on liver function tests and general stool examination
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
CO2 Laser Treatment of Cervical Ectropion
...Show More Authors

Cervical ectropion is considered to be a physiologic condition caused by columnar epithelium migration from the cervical canal into the vaginal portion of the cervix and usually there is no treatement for clinically asymptomatic cervical ectropion . Treatment can be achieved by thermal cauterization (Electrocautery), Cryosurgery or laser vaporization. Aim of the study: To study the effectiveness of CO2 laser (10600nm) in treatment of symptomatic cervical ectropion . Setting: The study was carried out at Laser Medicine Research Clinic at the Institute of Laser for Postgraduate Studies, University of Baghdad between the first of August 2013 to the end of October 2013. Patients and Methods: Ten female Patients with age range between 25-48 y

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Humidity effect on diffusion and length coefficient of radon in soil and building materials
...Show More Authors

View Publication
Scopus (19)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Al-kindy College Medical Journal
Pyogenic Discitis in Female after Delivery and Pelvic Surgery
...Show More Authors

Background: Pyogenic discitis most frequently occurs
after home delivery, hemorridectomy, and dilatation and
curettage. Discitis is generally due to blood borne bacterial
invasion of the disc from adjacent end-plate via
communicating vessels. Infective discitis remains an
uncommon, but potentially serious cause for back pain.
Delayed diagnosis can occur and a high index of suspicion
may occur.
Methods: The study included 30 patients suffering from
localized low back pain with limitation of movement.
Diagnosis was made by history, physical examination and
investigation mainly E.S.R and MRI.
Results: 50.3% of patient with discitis had a history of
vaginal delivery, 15% had a history of hemorridectomy

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Ultrasound assessment of normal splenic length and spleen to left kidney ratio in sample of Iraqi population
...Show More Authors

Background: Spleen is a hemopoietic organ which is capable of supporting elements of different systems. It is affected by several groups of diseases; inflammatory, hematopoietic, reticuloendothelial proliferation, portal hypertension and storage diseases. Ultrasound (US) may detect mild splenomegaly before it is clinically palpable. Knowledge of the normal range of spleen size in the population being examined is a prerequisite. Racial differences in splenic length could result in incorrect interpretation of splenic measurements and such differences would make it difficult to standardize expected splenic length and to determine non- palpable splenic enlargement.Objectives: To measure the normal values of splenic lengthin Iraqi subjects an

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 24 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Securing digital documents using digital watermarking
...Show More Authors

     The intellectual property of digital documents has been protected by using many methods of digital watermarking. Digital documents have been so much of advantages over print documents. Digital documents are less expensive and easy to store, transport, and searched compared to traditional print documents.  But it has its owner limitation too. A simple image editor can be used to modify and make a forged document. Digital documents can be tampered easily. In order to utilize the whole benefits of digital document, these limitations have to overcome these limitations by embedding some text, logo sequence that identifies the owner of the document..

In this research LSB  technique  has been used

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Indonesian Journal Of Electrical Engineering And Computer Science
Variable length error correcting code for image in OFDM and PAPR reduction
...Show More Authors

Data <span>transmission in orthogonal frequency division multiplexing (OFDM) system needs source and channel coding, the transmitted data suffers from the bad effect of large peak to average power ratio (PAPR). Source code and channel codes can be joined using different joined codes. Variable length error correcting code (VLEC) is one of these joined codes. VLEC is used in mat lab simulation for image transmission in OFDM system, different VLEC code length is used and compared to find that the PAPR decreased with increasing the code length. Several techniques are used and compared for PAPR reduction. The PAPR of OFDM signal is measured for image coding with VLEC and compared with image coded by Huffman source coding and Bose-

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
EMBEDDED LENGTH OF STEEL BARS IN SELF COMPACTED CONCRETE (SCC)
...Show More Authors

Experimental research was carried out on eight reinforced concrete beams to study the embedded length of the longitudinal reinforcement. Six beams were casted using self compacted concrete, and the two other beams were casted using normal concrete. The test was carried out on beams subjected to two point loads. The strain and the slip of the main reinforcement have been measured by using grooves placed during casting the beams at certain places. The measured strain used to calculate the longitudinal stresses (bond stress) surrounding the bar reinforcement, The study was investigated the using of self compacted concrete SCC on the embedded length of reinforcing bars, and comparing the results with normal concrete. The test results show th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu May 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Enhancement of Stream Cipher by Using Variant Register in Length
...Show More Authors

         Stream ciphers are an important class of encryption algorithms. There is a vast body of theoretical knowledge on stream ciphers, and various design principles for stream ciphers have been proposed and extensively analyzed. This paper  presents a new method of stream cipher, that by segmenting the plaintext into number of register then any of them combined to any other by using combination logic circuit (And, OR, JK, NOT, XOR), then using variant register in length as a key which provides security enhancement against attacks and then compare the strength of this method with RSA by calculaing the time necessary to get the original text by using the genetic algorithm. And the way that ha

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Dental caries and salivary Interleukin-6 among preterm postpartum women in relation to baby birth weight (Comparative study)
...Show More Authors

Background: The physiologic, biochemical and anatomic changes that occur during pregnancy are extensive and may be systemic or local. However, most of these changes return to pre pregnancy status six weeks postpartum. The aim of the study was to investigate the effect of dental caries among preterm postpartum women and it's relation to baby birth weight and salivary interleukin-6 (IL-6). Materials and methods: 66 postpartum women were examined, 33 preterm postpartum women (study group) and 33 full term postpartum women (control group). Dental caries was recorded using, decayed, missing and filled surfaces index, also assess the decayed lesion by severity. Salivary samples were taken from all subjects to estimate salivary IL-6 levels. Babie

... Show More
View Publication Preview PDF