BACKGROUND: Preterm labour is a major cause of perinatal morbidity and mortality, so it is important to predict preterm delivery using the clinical examination of the cervix and uterine contraction frequency. New markers for the prediction of preterm birth have been developed such as transvaginal ultrasound measurement of cervical length as this method is widely available. OBJECTIVE: To determine, whether transvaginal cervical length measurement predicts imminent preterm delivery better than digital cervical length measurement in women presented with preterm labour and intact membranes. PATIENTS AND METHODS: Two hundred women presented with preterm labour between 24 and 36+6 weeks of gestation were included in this study. All women subjected for digital and transvaginal ultrasound cervical length measurement and the outcome measures were occurrence of preterm delivery within 48 hours and within 7 days. RESULTS: Assessment of cervical length measurement using transvaginal ultrasound for the 200 women presented with preterm labour with intact membrane revealed that 8 (4%) delivered within 48 hours and 16 (8%) delivered within 7 days. According to the Bishop score, the test was positive if the Bishop score was ≥8, or 4-7 with cervical length ≤30 mm. The cut-off value for transvaginal ultrasound cervical length considered as 30 mm in the study group. CONCLUSION: Transvaginal sonographic measurement of cervical length can predict imminent preterm delivery in women presented with preterm uterine contractions and Bishop score between 4 - 7 compared with digital cervical length measurement.
The purpose of this paper is to understand the best processes that are currently used in managing talent in Australian higher education (HE) and to examine the policies in terms of talent management processes (TMPs) that are derived from objective one. Pragmatic benefits for academic institutions focused on enhancing talent.
This study selects the mixed method as its research design. In the qualitative study, there were three methods: brainstorming, focus group and individual interviews, followed by the quantitative questionnaire
Cervical cancer is the third most common cancer in women worldwide, and it has the fourth highest mortality rate among cancers in women. The present study aimed to reveal the impact of age factor in cervical abnormalities and cancers incidence in some Iraqi married women. 150 scraping cervical cells samples were collected from the women clinically diagnosed with cervical abnormalities and cancer who were divided into two groups; the first group included the women with abnormal pap smear which revealed 13.33% of women were less than 30 years and followed by 66.66% of women whose age between 30-50 years and 20% of them were more than 50 years old. While the second group iclude the women with normal Pap smear (Healthy women) which revealed tha
... Show MoreBackground: Spleen is a hemopoietic organ which is capable of supporting elements of different systems. It is affected by several groups of diseases; inflammatory, hematopoietic, reticuloendothelial proliferation, portal hypertension and storage diseases. Ultrasound (US) may detect mild splenomegaly before it is clinically palpable. Knowledge of the normal range of spleen size in the population being examined is a prerequisite. Racial differences in splenic length could result in incorrect interpretation of splenic measurements and such differences would make it difficult to standardize expected splenic length and to determine non- palpable splenic enlargement.Objectives: To measure the normal values of splenic lengthin Iraqi subjects an
... Show MoreBackground : Shoulder pain is a common problem that can pose difficult diagnostic and therapeutic challenges for the family physician It is the third most common musculoskeletal complaint in the general population, and account for 5% of all general practitioners musculoskeletal consults Objective: To determine the diagnostic performance of ultrasonography compared with the physical examination for detection of rotator cuff tears in painful shoulder syndrome. Method: Prospective study was done on seventy patients (48 male, 22 female), age ranged between 30-70 years (mean age 50 years), From February 2007 to July 2011, were subjected to comparative study in Al-Kindy teaching hospital with rotator cuff tears, including physical and ultrasonogr
... Show MoreBackground : Shoulder pain is a common problem that can pose difficult diagnostic and therapeutic challenges for the family physician It is the third most common musculoskeletal complaint in the general population, and account for 5% of all general practitioners musculoskeletal consults
Objective: To determine the diagnostic performance of ultrasonography compared with the physical examination for detection of rotator cuff tears in painful shoulder syndrome.
Method: Prospective study was done on seventy patients (48 male, 22 female), age ranged between 30-70 years (mean age 50 years), From February 2007 to July 2011, were subjected to comparative study in Al-Kindy teaching hospital with rotator cuff tears, including physical and ul
Background: Pyogenic discitis most frequently occurs
after home delivery, hemorridectomy, and dilatation and
curettage. Discitis is generally due to blood borne bacterial
invasion of the disc from adjacent end-plate via
communicating vessels. Infective discitis remains an
uncommon, but potentially serious cause for back pain.
Delayed diagnosis can occur and a high index of suspicion
may occur.
Methods: The study included 30 patients suffering from
localized low back pain with limitation of movement.
Diagnosis was made by history, physical examination and
investigation mainly E.S.R and MRI.
Results: 50.3% of patient with discitis had a history of
vaginal delivery, 15% had a history of hemorridectomy
Data <span>transmission in orthogonal frequency division multiplexing (OFDM) system needs source and channel coding, the transmitted data suffers from the bad effect of large peak to average power ratio (PAPR). Source code and channel codes can be joined using different joined codes. Variable length error correcting code (VLEC) is one of these joined codes. VLEC is used in mat lab simulation for image transmission in OFDM system, different VLEC code length is used and compared to find that the PAPR decreased with increasing the code length. Several techniques are used and compared for PAPR reduction. The PAPR of OFDM signal is measured for image coding with VLEC and compared with image coded by Huffman source coding and Bose-
... Show More