Preferred Language
Articles
/
_hZa1YgBVTCNdQwCyYIi
Comparism Between Transvaginal Cervical Length Measurement and Digital Examination in Prediction of Imminent preterm Delivery
...Show More Authors

BACKGROUND: Preterm labour is a major cause of perinatal morbidity and mortality, so it is important to predict preterm delivery using the clinical examination of the cervix and uterine contraction frequency. New markers for the prediction of preterm birth have been developed such as transvaginal ultrasound measurement of cervical length as this method is widely available. OBJECTIVE: To determine, whether transvaginal cervical length measurement predicts imminent preterm delivery better than digital cervical length measurement in women presented with preterm labour and intact membranes. PATIENTS AND METHODS: Two hundred women presented with preterm labour between 24 and 36+6 weeks of gestation were included in this study. All women subjected for digital and transvaginal ultrasound cervical length measurement and the outcome measures were occurrence of preterm delivery within 48 hours and within 7 days. RESULTS: Assessment of cervical length measurement using transvaginal ultrasound for the 200 women presented with preterm labour with intact membrane revealed that 8 (4%) delivered within 48 hours and 16 (8%) delivered within 7 days. According to the Bishop score, the test was positive if the Bishop score was ≥8, or 4-7 with cervical length ≤30 mm. The cut-off value for transvaginal ultrasound cervical length considered as 30 mm in the study group. CONCLUSION: Transvaginal sonographic measurement of cervical length can predict imminent preterm delivery in women presented with preterm uterine contractions and Bishop score between 4 - 7 compared with digital cervical length measurement.

View Publication
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Engineering
Buckling Loads and Effective Length Factor for Non-Prismatic Columns
...Show More Authors

Based on a finite element analysis using Matlab coding, eigenvalue problem has been formulated and solved for the buckling analysis of non-prismatic columns. Different numbers of elements per column length have been used to assess the rate of convergence for the model. Then the proposed model has been used to determine the critical buckling load factor () for the idealized supported columns based on the comparison of their buckling loads with the corresponding hinge supported columns . Finally in this study the critical buckling factor () under end force (P) increases by about 3.71% with the tapered ratio increment of 10% for different end supported columns and the relationship between normalized critical load and slenderness ratio was g

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Value of Ultrasonography in The Diagnosis and Evaluation of Early Therapeutic Response of Cervical Tuberculous Lymphadenitis
...Show More Authors

ABSTRACT Background: Tuberculosis is a worldwide infectious disease in spite of advancement in health care system. Tuberculous lymphadenitis is the most prevalent form of extra pulmonary tuberculosis with predilection of cervical lymph nodes. Objectives: To evaluate the reliability of grey scale ultrasonography together with color Doppler in the diagnosis of cervical tuberculous lymph adenitis and evaluation of early therapeutic response. Subjects and methods:From July 2015 to May 2016 in Al-Karama teaching hospital /Kut city- Wasit-Iraq, 25 patients (14 males and 11 females) with ages range from (6-50) years. Ultrasonography examination was done for all patients and grey scale criteria (distribution, size, shape, echogenicity, echogenic hi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Nov 03 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences( P-issn 1683 - 3597 E-issn 2521 - 3512)
Diacerein Loaded Novasome for Transdermal Delivery: Prepartion , In-Vitro Characterization and Factors Affecting Formulation
...Show More Authors

Diacerein (DCN) is a semi-synthetic anthraquinone derivative of Rhein that is indicated for the management of osteoarthritis. Diacerein exhibits poor dissolution in the GIT fluids and suffers from low bioavailability upon oral administration in addition to the laxative effect of Rhein metabolites. The aim of the present study was to develop novasomal vesicles with optimized entrapment efficiency and size to serve as a carrier for transdermal delivery of diacerein. Novasomal vesicles were prepared by thin film hydration method thin film hydration. The prepared vesicles were optimized utilizing different surfactant to cholesterol molar ration, sonication type, different sonication times and varying fatty acid level. The prepared vesicles were

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Molecular Detection of High-Risk Human Papillomavirus Genotypes from Cervical Lesions in Baghdad
...Show More Authors

Objective Using two complementary techniques of virus detection human papillomavirus (HPV)[capture of hybrids (CH) and polymerase chain reaction (PCR)], relate the cytological study and/or cervical biopsy with high-risk HPV (HPV-HR) genotypes presence, as well as relating their viral load (VL). Methods About 272 women, who presented most cell alterations compatible with lesions cervical HPV, which has been detected in all high risk by the CH method and HPV genotype detection by PCR. Results In 22% of the patients it was not detected HPV DNA. Genotype 16 and/or 18 was prevalent and was found in 33% of the 212 women studied, meanwhile, mixed infections were found by several genotypes in 25%. In as for the histological lesions found, in 61 pat

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Thu Apr 25 2019
Journal Name
Journal Of Pharmacy Research
Pulsatile drug delivery system-review article
...Show More Authors

Pulsatile drug delivery systems (PDDS) are developed to deliver drug according to circadian behavior of diseases. They deliver the drug at the right time, action and in the right amount, which provides more benefit than conventional dosages and increased patient compliance. The drug is released rapidly and completely as a pulse after a lag time. These systems are beneficial for drugs with chrono-pharmacological behavior, where nighttime dosing is required and for the drugs having a high first-pass effect and having specific site of absorption in the gastrointestinal tract. This article covers methods and marketed technologies that have been developed to achieve pulsatile delivery. Diseases wherein PDDS are promising include asthma, peptic u

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 24 2018
Journal Name
Journal Of Pharmacy Research
Transdermal drug delivery system: A review
...Show More Authors

Transdermal drug delivery has made an important contribution to medical practice but has yet to fully achieve its potential as an alternative to oral delivery and hypodermic injections. Transdermal therapeutic systems have been designed to provide controlled continuous delivery of drugs through the skin to the systemic circulation. A transdermal patch is an adhesive patch that has a coating of drug; the patch is placed on the skin to deliver particular amount of drug into the systemic circulation over a period of time. The transdermal drug delivery systems (TDDS) review articles provide information regarding the transdermal drug delivery systems and its evaluation process as a ready reference for the research scientist who is involved

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 12 2024
Journal Name
Revista Latinoamericana De Hipertension
Most common risk factors distribution for cervical cancer
...Show More Authors

Scopus
Publication Date
Sun Dec 27 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Phytochemical Investigation and Anti-angiogenic Examination of Iraqi Vigna radiata L. Seeds and Sprouts
...Show More Authors

Abstract

  The objective of this study was to investigate the phytochemical constituents of two different parts of Vigna radiata (seeds and sprouts), and identify their  anti angiogenic activity .the goal was achieved by Preliminary qualitative phytochemical screening for crude ethanolic extract of two parts of plant

 ; rat aorta anti-angiogenesis assay had been conducted for both extracts .   isolation , separation and purification of some phytochemical constituents that belong to important groups (flavonoids) from  n-butanol fraction extract of Vigna radiata plant had been done in pure form by using preparative thin layer chromatography ( PTLC ) and then

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
In Vitro Study of MefenamateStarch as Drug Delivery System
...Show More Authors

Mefenamic acid was esterified with starchwith[1:1] Molar ratio, as drug substituted with natural polymer, to prolongthe period of hydrolysis of drug polymer with other advantages. The new prodrug starch was characterized by FT-IR and UV-Visible and 1H-NMR spectroscopies. The physical properties were studied and controlled drug release was studied in different pH values at 37oC. The stability of drug was carried out by measuring the absorbance of mefenamic starch which hydrolyzed in HCl solution of pH 1.1 (artificial gastric fluid) and phosphate buffer of pH 7.4 (simulating intestinal fluid SIF) at 37oC for several days. The thermal analysis such as DSC was studied.

View Publication Preview PDF
Crossref
Publication Date
Tue Aug 15 2023
Journal Name
Al-academy
Digital technologies in the means of communication
...Show More Authors

Modern digital technologies have affected the means of communication in terms of structure, function and methods of dealing with them, and the communication process has changed, becoming bilateral, reciprocal and interactive, after it was one-way and limited in circulation and the roles changed, so the receiver became the sender and reversed is correct, and the culture of the active user and the participant spread, and the communication process became continuous.
The international information network has provided new electronic channels in the media and communication that are not known and opened a new era for these means, which led to a trend towards digital media in an unprecedented way.
The new communication platforms are the re

... Show More
View Publication Preview PDF
Crossref