Background: This study evaluated the influence of different fiber formulations incorporation in resin composite on cuspal deflection (CD) of endodontically-treated teeth with mesio-occluso-distal (MOD) cavities. Materials and Methods: Thirty-two freshly extracted maxillary premolar teeth received MOD cavity preparation followed by endodontic treatment using single cone obturation technique, and divided into: Group I: direct composite resin only using a centripetal technique, Group II: direct composite resin with short fiber-reinforced composite (everX Flow), Group III: direct composite resin with leno wave ultra-high molecular weight polyethylene (LWUHMWPE) fibers placed on the cavity floor, and Group IV: direct composite resin with LWUHMWPE fibers placed circumferentially around the cavity walls (wallpapering technique). The CD was measured using a novel digital evaluation method, whereby each tooth was scanned by a desktop scanner (Medit T710) at three different time intervals: before and after cavity preparation, and after restoration. The intercuspal distance (ICD) was measured digitally in μm at each interval using Medit compare metrology software, followed by measurement of the CD by subtracting the ICD after cavity preparation; and after restoration from the before preparation one to obtain the “after cavity preparation CD1” and “the after restoration CD2”, respectively. The data were analyzed using one-way ANOVA and Tukey HSD tests at a significance level of 0.05. Results: The highest CD was recorded in Group I with statistically significant differences with all other groups (P<0.05). No statistically significant differences were found between the other groups (Groups II, III, and IV) (P>0.05). Conclusions: There was an inward deflection of the cusps in all groups following cavity preparation and restoration as elicited by the negative CD1 and CD2 values. The incorporation of fibers, regardless of their type or orientation, resulted in a significant reduction in CD of endodontically treated premolar teeth as compared with those restored with resin composite alone.
Membrane manufacturing system was operated using dry/wet phase inversion process. A sample of hollow fiber membrane was prepared using (17% wt PVC) polyvinyl chloride as membrane material and N, N Dimethylacetamide (DMAC) as solvent in the first run and the second run was made using (DMAC/Acetone) of ratio 3.4 w/w. Scanning electron microscope (SEM) was used to predict the structure and dimensions of hollow fiber membranes prepared. The ultrafiltration experiments were performed using soluble polymeric solute poly ethylene glycol (PEG) of molecular weight (20000 Dalton) 800 ppm solution 25 °C temperature and 1 bar pressure. The experimental results show that pure water permeation increased from 25.7 to 32.2 (L/m2.h.bar) by adding a
... Show MoreMembrane manufacturing system was operated using dry/wet phase inversion process. A sample of hollow fiber membrane was prepared using (17% wt PVC) polyvinyl chloride as membrane material and N, N Dimethylacetamide (DMAC) as solvent in the first run and the second run was made using (DMAC/Acetone) of ratio 3.4 w/w. Scanning electron microscope (SEM) was used to predict the structure and dimensions of hollow fiber membranes prepared. The ultrafiltration experiments were performed using soluble polymeric solute poly ethylene glycol (PEG) of molecular weight (20000 Dalton) 800 ppm solution 25 °C temperature and 1 bar pressure. The experimental results show that pure water permeation increased from 25.7 to 32.2 (L/m2.h.bar) by adding aceton
... Show MoreHand-lay up method was used to prepare the samples made of epoxy (EP) as a matrix reinforced with chopped carbon fibers (CCF). The fatigue behavior of epoxy resin /chopped carbon fiber composites was studied with different weight percentage of chopped carbon fibers (2.5%,5%,7.5%,10%,12.5%). The fatigue test was carried out under alternate bending method, which was made by applying sinusoidal wave with constant displacement (15mm), stress ratio R=-1,and loading frequency 10Hz, which is believed to give a negligible temperature rise during the test. The results of the maximum stress, fatigue strength, fatigue limit and fatigue life of the tested composites are calculated from stress(S)-number of cycles(N) (S-N) curves.
It was shown that
Background: The timing of eruption of permanent teeth is of considerable importance to the dental health planning for diagnostic, preventive and therapeutic measures for children and teenagers. The purposes of this study were to determine timing of maxillary and mandibular permanent teeth emergence (except third molars) and to evaluate the effect nutritional status by anthropometric measures on the eruption time of permanent teeth, investigations had been done according to jaw and gender variations. Materials and Methods: This study was conducted among four to fifteen years old children and teenagers from kindergarten and schools in Basrah city in the south region of Iraq. The total sample composed of 1807 children and teenagers that were
... Show MoreThis paper deals with finite element modeling of the ultimate load behavior of double skin composite (DSC) slabs. In a DSC slab, shear connectors in the form of nut bolt technique studs are used to transfer shear between the outer skin made of steel plates and the concrete core. The current study is based on finite element analysis using ANSYS Version 11 APDL release computer program. Experimental programmes were carried out by the others, two simply supported DSC beams were tested until failure under a concentrated load applied at the center. These test specimens were analyzed by the finite element method and the analyses have shown that these slabs displayed a high degree of flexural characteristics, ultimate strength,
... Show MoreThe change in the optical properties for samples of pure PVA and PVA /K2CrO4composite have been studied .The samples were prepared with different percentage (1,3,5,and 7)%wt of K2CrO4 by casting method technique .In this work ,we are study the absorption ,reflectance spectra ,absorption coefficient, energy gap ,extinction coefficient ,and transmittance spectra as a function of wavelength range (200-800)nm ,Also real and imaginary part of dielectric constant have been studied in the range of wave length .The results exhibit the optical properties change by the increase of K2CrO4 concentration, and the values of energy gap for indirect transitions decrease by the increase of the concentration of K2CrO4
... Show MoreThe study of determing Uranium concentration in samples of teeth is the first of its kind in the Iraq . In this study Uranium concentration has been measured was (32) samples of child teeth distributed on the some of middle and south governorate of Iraq (Muthana – Dekar – Basrah – Najaf – Karbalah – Waset – Babel – Baghdad) . The Uranium concentration in teeth samples has been measured by using fission tracks registration in (CR-39) track detector that caused by the bombardment of (U235) with thermal neutrons falx from (24Am.Be) neutron source that has flux of (5x103n.cm-2S-1). The result obtained show that the Uranium concentrations in governorates were (0.18ppm), (0.172ppm), (0.160ppm), 0.150ppm) (0.89ppm), (0.07ppm) , (0.
... Show MoreThe media of all kinds have the task of introducing, expressing and objectively representing the cultures of different societies in various types and forms of press and media. The precept of media pluralism is the basis for freedom of expression & the cornerstone of its realization. Therefore, it is linked to the establishment of several conditions and elements in order to establish it as a principle and practice. Issues of cultural diversity in media and cultural pluralism are one of the most important elements and indicators. So, this paper aims to shed light on the concept of media pluralism and related concepts within the framework of cultural diversity and multicultural indicators. Thus, highlighting the feature
... Show More