Preferred Language
Articles
/
ZRZcU4cBVTCNdQwC8kV0
DESIGN, CONSTRUCTION AND TESTING OF LOW SPEED WIND TUNNEL WITH ITS MEASUREMENT AND INSPECTION DEVICES
...Show More Authors

A low speed open circuit wind tunnel has been designed, manufactured and constructed at the Mechanical Engineering Department at Baghdad University - College of Engineering. The work is one of the pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes the first part of the work; that is the design calculations, simulation and construction. It will be followed by a second part that describes testing and calibration of the tunnel. The proposed wind tunnel has a test section with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70 m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flow disturbances in the test section. The design philosophy is discussed and methods for wind tunnel calculation are outlined. Simulation of wind tunnel using ANSYS shows no separation of flow along wind tunnel. Construction steps are also included in present work

View Publication
Publication Date
Wed Apr 30 2025
Journal Name
Journal Of Physical Education
Special Speed Endurance Effect of 800m Running on Some Physiological Indictors and Achievement of Physically Disabled Men Class (T47 – T46)
...Show More Authors

View Publication
Publication Date
Fri May 19 2023
Journal Name
Revista Iberoamericana De PsicologÍa Del Ejercicio Y El Deporte
The Effect of a Training Curriculum According To the Physiological Index and the Transitional Speed of the 100m Hurdles Runner
...Show More Authors

Recently, that there has been a decline in the levels of female players for this event in recent years compared to developments in the world, as this activity depends to achieve the highest level of performance on the physical capabilities and physiological indicators of the player who It is reflected in the achievement, which results in the loss of time for Iraqi female runners compared to the world champions in the (100) meter hurdles competition, which reflects on the level of achievement. The two researchers used the experimental approach in addressing the research problem, and the experimental design used the method of the two equal groups, the two experiments with the pre and post-tests. Female runner and second experimental group (4)

... Show More
View Publication Preview PDF
Scopus
Publication Date
Sat Jun 02 2018
Journal Name
Iosr Journal Of Applied Physics (iosr-jap)
Measurement of Radioactivity inMarsh Sediments of South Iraq
...Show More Authors

Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Radiation doses assessment for workers on radiation measuring devices response check in RNSD laboratories
...Show More Authors

Radiation measuring devices need to periodic calibration process to examine their sensitivity and the extent of the response. This study is used to evaluate the radiation doses of the workers in the laboratories of the Directorate of Safety as a result of the use of point sources in calibrating of the devices in two ways, the first is the direct measurement by the FAG device and the others using RESRAD and RAD PRO programs. The total doses values using FAG were (2.57 μSv/y, 102.3 μSv/y and 20.75 μSv/y for TLD laboratory, Gamma spectroscopy analyses (GSA) laboratory and equipment store respectively, and the total doses that calculated using RESRAD and RAD PRO were 1.518 μSv/y, 76.65 μSv/y and 21.2 μSv/y for the above laboratories. t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.
Results show that high similarity between water phantom and actual planning for th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 28 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied. Results show that high similarity between water phantom and actual planning for

... Show More
Publication Date
Thu Jul 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Measurement of Radon Concentration in Drink and Well Water Samples for Selected Regions in Baghdad City
...Show More Authors

 The concentration of radon gas in the samples for drinking water and wells in the same place from selected homes in which wells were built in the Hay-al-Bayaa region of Baghdad was measured, by using a CR-39 nuclear track detector. It turns out that the maximum value of the concentration of radon in drinking water was 3.83 Bq/L, and the lowest was 2.30 Bq/L. As for the estimation of radon gas concentration in well water samples, the highest value was 5.6 Bq/L, while the lowest one was 3.1 Bq/L. In order to assess the committed effective dose received by the public due to the inhalation of radon gas. The highest value of the annual effective dose in drinking water was recorded in Al-Bayaa region, which is equal to 14.30 μSv/y, while th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Electric Power Systems Research
Analytical and measurement-based wideband two-port modeling of DC-DC converters for electromagnetic transient studies
...Show More Authors

Power-electronic converters are essential elements for the effective interconnection of renewable energy sources to the power grid, as well as to include energy storage units, vehicle charging stations, microgrids, etc. Converter models that provide an accurate representation of their wideband operation and interconnection with other active and passive grid components and systems are necessary for reliable steady state and transient analyses during normal or abnormal grid operating conditions. This paper introduces two Laplace domain-based approaches to model buck and boost DC-DC converters for electromagnetic transient studies. The first approach is an analytical one, where the converter is represented by a two-port admittance model via mo

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2011
Journal Name
International Journal Of Computer Theory And Engineering
MIPOG - An Efficient t-Way Minimization Strategy for Combinatorial Testing
...Show More Authors

View Publication
Crossref (16)
Crossref
Publication Date
Tue Jan 01 2008
Journal Name
Lecture Notes In Computer Science
IRPS – An Efficient Test Data Generation Strategy for Pairwise Testing
...Show More Authors

View Publication
Scopus (20)
Crossref (7)
Scopus Crossref