Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.
Results show that high similarity between water phantom and actual planning for this reason water is taken as phantom for Quality Assurance (QA) and calculation the depth dose. When increasing the field size, the percentage of surface dose increases that this could be caused by an increase of the amount of scattering in the larger fields.
Conclusion: There is almost no difference in depth dose between homogenous planning and water phantom.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 28 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied. Results show that high similarity between water phantom and actual planning for

... Show More
Publication Date
Mon Aug 26 2019
Journal Name
Iraqi Journal Of Science
Depth dose measurement in water phantom for two X-ray energies (6MeV and 10MeV) in comparison with actual planning

The purpose of this study is to measure doses delivered at different depths in water phantom at vertical position in comparison with the actual planning in order to verify the dose delivered to the tumor in addition to the measurement of the effect penumbra dose to assess the dose leaking to the healthy soft tissue.

     Percentage depth dose (PDD) values was measured at field sizes (5×5,10×10,15×15, and 20×20) cm2, and the depth dose was measured between (0-16) cm deep at 4cm intervals, for both energies 6 MeV and 10 MeV X-ray beam. Other readings were taken at different distances 1cm and 2cm outside of the actual beam in orthogonal directions at depth of 4 cm. These measurements we

... Show More
Scopus (1)
Scopus Crossref
View Publication Preview PDF
Publication Date
Mon Oct 30 2017
Journal Name
International Journal Of Science And Research
Measurements of X-Ray Dose Delivered at Different Depths Applied on Water Phantom

Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1

... Show More
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Mathematical Models Used for Brachytherapy Treatment Planning Dose Calculation Algorithms

Brachytherapy treatment is primarily used for the certain handling kinds of cancerous tumors. Using radionuclides for the study of tumors has been studied for a very long time, but the introduction of mathematical models or radiobiological models has made treatment planning easy. Using mathematical models helps to compute the survival probabilities of irradiated tissues and cancer cells. With the expansion of using HDR-High dose rate Brachytherapy and LDR-low dose rate Brachytherapy for the treatment of cancer, it requires fractionated does treatment plan to irradiate the tumor. In this paper, authors have discussed dose calculation algorithms that are used in Brachytherapy treatment planning. Precise and less time-consuming calculations

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Oct 30 2022
Journal Name
Iraqi Journal Of Science
Measurement of Absorbed Dose in Water Using Co-60 gamma source Teletherapy Units According to IAEA Dosimetry Protocols

      Modern radiotherapy facilities like 3-Dimensional conformal radio therapy (3DCRT), Intensity Modulated Radiotherapy (IMRT), were recently suggested in Co-60 machine with Multi-leaf Collimator (MLC). In this study, two reference chambers NE-2571#1205 and NE2581#537 were used for absolute dose measurement in Equinox accelerator. A comparison of dose measurement by two different IAEA protocols TRS-277 and TRS-398 has been studied. Analyzing TRS-398, a common shaped empirical formula was developed for the four Co-60 units of four Medical Colleges in Bangladesh with fitting parameters. It was found that an average discrepancy in the determination of absorbed dose in water among the two different protocols TRS-277 and TRS-398 were 1

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Wed Mar 29 2023
Journal Name
Aip Conference Proceedings
Measurement radon concentrations in samples for drinking water

The principal forms of radiation dosage for humans from spontaneous radiation material are being recognized as radon and its progenitors in the interior environment. Radiation-related health risks are caused by radon in water supply, which can be inhaled or ingested. Materials and Methods: The solid-state CR-39 nuclear trace detectors method was using in this research for measuring accumulation of radioactivity in water supply in different locations of Iraq's southwest corner of Baghdad. In Baghdad district, 42 samples were selected from 14 regions (3 samples out of each region) and put in dosimeters for 50 days. Results: The mean radon concentration was 49.75 Bq/m3, that is lower than the internationally recognized limit of 1100 Bq /m3. Th

... Show More
Scopus Crossref
View Publication
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
Influence of the Beam Size Radiation on the Depth Dose by Using 60Co

Radiotherapy is medical use of ionizing radiation, and commonly applied to the
cancerous tumor because of its ability to control cell growth.
The amount of radiation used in photon radiation therapy called dose (measured
in grey unit), which depend on the type and stage of cancer being treated.
In our work, we studied the dose distribution given to the tumor at different
depths (zero-20 cm) treated with different field size (4×4- 23×23 cm).
Results show that the deeper treated area has less dose rate at the same beam
quality and quantity. Also it has been noted increasing in the field increasing in the
depth dose at the same depth even if the radiation energy is constant. Increasing in
radiation dose attribut

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 04 2013
Journal Name
Iraqi Journal Of Science
Influence of the Beam Size Radiation on the Depth Dose by Using 60Co

Radiotherapy is medical use of ionizing radiation, and commonly applied to the cancerous tumor because of its ability to control cell growth. The amount of radiation used in photon radiation therapy called dose (measured in grey unit), which depend on the type and stage of cancer being treated. In our work, we studied the dose distribution given to the tumor at different depths (zero-20 cm) treated with different field size (4×4- 23×23 cm). Results show that the deeper treated area has less dose rate at the same beam quality and quantity. Also it has been noted increasing in the field increasing in the depth dose at the same depth even if the radiation energy is constant. Increasing in radiation dose attributed to the scattere

... Show More
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Predicting Water Depth of Lake Using Remote Sensing image

One of the most important of satellite image is studying the surface water
according of its distribution and depth. In this work, three images have been taken
for Baghdad and surrounding for year (1991, 1999 and 2014) and by using of envi
program has been used. Different classes have been evaluated for Al-Habania and
Al-Razaza River according to its depth and water reflectance. In the present work
four types of water depth (very shallow, shallow, moderate, and deep area) have
been detected.

View Publication Preview PDF
Publication Date
Wed Nov 30 2022
Journal Name
Iraqi Journal Of Science
Measurement of Radiation Background and Estimation of the Annual Effective Dose for Workers in the Radiochemistry Laboratories at the Al-Tuwaitha Site

      This study was achieved to calculate the annual effective dose equivalent (AEDE) in units of (mSv.y-1), and the average radiation dose rate (ADR) in units of (μSv.h-1) which were measured by portable devices.   The study was carried out on the workers of the destroyed radiochemistry laboratory located at Al-Twuitha nuclear site (south of Baghdad). Radiation background was determined for comparison with the radioactive dose of soil samples measured with HPGe detector and portable devices type LUDLUM.  The radioactivity levels of the area around the radiochemistry laboratory building were within the limits of radiation background.  The result showed a significant increase of the annua

... Show More
Scopus Crossref
View Publication Preview PDF