Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied. Results show that high similarity between water phantom and actual planning for this reason water is taken as phantom for Quality Assurance (QA) and calculation the depth dose. When increasing the field size, the percentage of surface dose increases that this could be caused by an increase of the amount of scattering in the larger fields. Conclusion: There is almost no difference in depth dose between homogenous planning and water phantom

Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.
Results show that high similarity between water phantom and actual planning for th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 26 2019
Journal Name
Iraqi Journal Of Science
Depth dose measurement in water phantom for two X-ray energies (6MeV and 10MeV) in comparison with actual planning
...Show More Authors

The purpose of this study is to measure doses delivered at different depths in water phantom at vertical position in comparison with the actual planning in order to verify the dose delivered to the tumor in addition to the measurement of the effect penumbra dose to assess the dose leaking to the healthy soft tissue.

     Percentage depth dose (PDD) values was measured at field sizes (5×5,10×10,15×15, and 20×20) cm2, and the depth dose was measured between (0-16) cm deep at 4cm intervals, for both energies 6 MeV and 10 MeV X-ray beam. Other readings were taken at different distances 1cm and 2cm outside of the actual beam in orthogonal directions at depth of 4 cm. These measurements we

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Mathematical Models Used for Brachytherapy Treatment Planning Dose Calculation Algorithms
...Show More Authors

Brachytherapy treatment is primarily used for the certain handling kinds of cancerous tumors. Using radionuclides for the study of tumors has been studied for a very long time, but the introduction of mathematical models or radiobiological models has made treatment planning easy. Using mathematical models helps to compute the survival probabilities of irradiated tissues and cancer cells. With the expansion of using HDR-High dose rate Brachytherapy and LDR-low dose rate Brachytherapy for the treatment of cancer, it requires fractionated does treatment plan to irradiate the tumor. In this paper, authors have discussed dose calculation algorithms that are used in Brachytherapy treatment planning. Precise and less time-consuming calculations

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Oct 30 2017
Journal Name
International Journal Of Science And Research
Measurements of X-Ray Dose Delivered at Different Depths Applied on Water Phantom
...Show More Authors

Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1

... Show More
Publication Date
Sat Oct 01 2022
Journal Name
Baghdad Science Journal
Modeling Jar Test Results Using Gene Expression to Determine the Optimal Alum Dose in Drinking Water Treatment Plants
...Show More Authors

Coagulation is the most important process in drinking water treatment. Alum coagulant increases the aluminum residuals, which have been linked in many studies to Alzheimer's disease. Therefore, it is very important to use it with the very optimal dose. In this paper, four sets of experiments were done to determine the relationship between raw water characteristics: turbidity, pH, alkalinity, temperature, and optimum doses of alum [   .14 O] to form a mathematical equation that could replace the need for jar test experiments. The experiments were performed under different conditions and under different seasonal circumstances. The optimal dose in every set was determined, and used to build a gene expression model (GEP). The models were co

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Oct 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Comparison Some Parametric and Non –parametric Methods To Estimate Median Effective Dose ( ED5
...Show More Authors

            In this paper the research represents an attempt of expansion in using the parametric and non-parametric estimators to estimate the median effective dose ( ED50 ) in the quintal bioassay and comparing between  these methods . We have Chosen three estimators for Comparison. The first estimator is
( Spearman-Karber )  and the second estimator is ( Moving Average ) and The Third estimator  is ( Extreme Effective Dose ) .
We used a minimize Chi-square as a parametric method. We made a Comparison for these estimators by calculating the mean square error of (ED50) for each one of them and comparing it with the optimal the mean square

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 01 2007
Journal Name
Journal Of Economics And Administrative Sciences
Alternative distribution to estimate the Dose – Response model in bioassay excrement
...Show More Authors

 Alternative  distribution  to estimate the Dose – Response  model in bioassay  excrement

This research   concern to study five different distribution (Probit , Logistic, Arc sine , extreme value , One hit  ), to estimate  dose –response model by using m.l.e  and probit method This is done by determining different  weights in each  distribution in addition find all particular statistics for vital model . 

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Baghdad Science Journal
Measurement of the Radon Concentration and Annual Effective Dose in Malva sylvestris (Khabbaz) Plant Used in Traditional Medicine and Food
...Show More Authors

In this study, the radon gas concentration as well as the annual effective dose in leaves of the Malvasylvestris (Khabbaz) plant used in the traditional treatment and as food in Iraq, for this, it is necessary to evaluate the concentrations radon gas, which were measured using solid state nuclear track detectors (SSNTDs) CR-39 technique.  The  concentration and annual effective dose in samples were collected from Baghdad city ranged from minimum to maximum value 15.815 , 0.498 , 54.445 , 1.717  respectively, while the values of  concentration and annual effective dose in a sample collected from Karbala are 15.297 ,0.482 . These values of  concentration and annual effective dose less were compared with th

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Apr 25 2019
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
MEASUREMENT OF CHEMICAL AND PHYSICAL PROPERTIES IN SOME MINERAL WATER SAMPLES FILLED IN THE MARKETS OF THE PROVINCE OF NAJAF AND COMPARE WITH THE IRAQI AND INTERNATIONAL RATIOS.: MEASUREMENT OF CHEMICAL AND PHYSICAL PROPERTIES IN SOME MINERAL WATER SAMPLES FILLED IN THE MARKETS OF THE PROVINCE OF NAJAF AND COMPARE WITH THE IRAQI AND INTERNATIONAL RATIOS.
...Show More Authors

In this research, a selection of some mineral water was selected on the basis of being the most marketed by the owners of shops in Najaf province, with six types, where daily samples of this water were taken by 50 ml for two months from (1/11/2018 -1/1/2019). The following ions concentrations were measured (Br-, Cl-, F-, NO3-, SO42-, Na+, K+, Ca2+, Mg2+), pH and the electrical conductivity were measured and the results were compared with the allowable rates according to the international organizations. It was noted that they conform to international and Iraqi standards.

View Publication Preview PDF
Publication Date
Sun Sep 22 2019
Journal Name
Baghdad Science Journal
Geometry, and Normal Modes of Vibration (3N-6) for Di and Tetra-Rings Layer (6, 0) Linear (Zigzag) SWCNTs; A DFT Treatment
...Show More Authors

            Density Functional Theory (DFT) method of the type (B3LYP) and a Gaussian basis set (6-311G) were applied for calculating the vibration frequencies and absorption intensities for normal coordinates (3N-6) at the equilibrium geometry of the Di and Tetra-rings layer (6, 0) zigzag single wall carbon nanotubes (SWCNTs) by using Gaussian-09 program. Both were found to have the same symmetry of D6d point group with C--C bond alternation in all tube rings (for axial bonds, which are the vertical C--Ca bonds in rings layer and for circumferential bonds C—Cc in the outer and mid rings bonds). Assignments of the modes of vibration IR active and inactive vibration frequ

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Clarivate Crossref