Preferred Language
Articles
/
ZBfv9o4BVTCNdQwCiVrN
Role of Combining Colour Doppler and Grey Scale Ultrasound in Differentiating Benign from Malignant Ovarian Masses
...Show More Authors
Abstract<p>The aim of this study was to evaluate ovarian masses with conventional grey scale ultrasonography and colour Doppler flow imaging and to assess the diagnostic reliability of these methods in differentiating benign and malignant ovarian masses.</p><p>We assessed 56 patients with an ovarian mass. Morphological characterisation of the mass was performed utilising the Sassone score. Colour Doppler parameters were recorded for each patient, and the Caruso vascular score was also applied. The results were compared with surgical/pathological and/or follow-up scans.</p><p>Using the Sassone score, overall reliability in differentiating ovarian masses had a sensitivity of 89.5% and a specificity of 78.4%. Using the Caruso score alone, we found a sensitivity of 89.5% and a specificity of 86.5%. Using the Sassone and Caruso scores together, we found a sensitivity of 94.7% and a specificity of 89.1%.</p><p>Combining both morphological and colour Doppler scores in the evaluation of ovarian masses obtained higher specificity, sensitivity, and accuracy than was obtained using a single score only.</p>
Scopus Crossref
View Publication
Publication Date
Sat Apr 06 2024
Journal Name
Al- Anbar Medical Journal
Metastatic Ovarian Tumor from Incidental Renal Cell Carcinoma: A Case Report and Literature Review
...Show More Authors

View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Automated breast ultrasound: A comparison study with handheld ultrasound in detection and characterization of lesions in mammographically dense breast
...Show More Authors

Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts. Objectives: To evaluate the diagnostic efficacy of Automated breast ultrasound and compare

... Show More
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Automated breast ultrasound: A comparison study with handheld ultrasound in detection and characterization of lesions in mammographically dense breast
...Show More Authors

Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts.

Objectives:<

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Feb 02 2016
Journal Name
International Journal Of Computer Science And Mobile Computing
Increasing Security in Steganography by Combining LSB and PRGN
...Show More Authors

With the increasing rate of unauthorized access and attacks, security of confidential data is of utmost importance. While Cryptography only encrypts the data, but as the communication takes place in presence of third parties, so the encrypted text can be decrypted and can easily be destroyed. Steganography, on the other hand, hides the confidential data in some cover source such that the existence of the data is also hidden which do not arouse suspicion regarding the communication taking place between two parties. This paper presents to provide the transfer of secret data embedded into master file (cover-image) to obtain new image (stego-image), which is practically indistinguishable from the original image, so that other than the indeed us

... Show More
Publication Date
Wed Oct 05 2022
Journal Name
Journal Of Basic Science
Loss in the Translation of Colour Euphemstic Expressions in the Qur’an: A Pragmatic Analysis
...Show More Authors

Publication Date
Wed Apr 02 2025
Journal Name
Retos
The effect of rehabilitation exercises accompanied by ultrasound waves in reducing pain and healing from carpal tunnel compression
...Show More Authors

Objective: The current study aimed identifying the impact of rehabilitative exercises combined with ultrasonic waves on reducing pain in people with carpal tunnel compression and determining how these activities affect range of motion of the upper limb for those suffering from carpal tunnel compression. Research methodology: With pre- and post-tests, the researchers employed the experimental method in the form of two equal groups, the experimental and the control. The scientific community and sample are among the priorities that fall on the researcher, so The scientific community is determined by those suffering from carpal tunnel compression, numbering (14) patients. (12) Patients were approved and two were excluded from the resear

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Nov 17 2016
Journal Name
International Journal Of Computer Applications
Colour Recognizing Robot Arm Equipped with a CMOS Camera and an FPGA
...Show More Authors

In this paper a system is designed on an FPGA using a Nios II soft-core processor, to detect the colour of a specific surface and moving a robot arm accordingly. The surface being detected is bounded by a starting mark and an ending mark, to define the region of interest. The surface is also divided into sections as rows and columns and each section can have any colour. Such a system has so many uses like for example warehouses or even in stores where their storing areas can be divided to sections and each section is coloured and a robot arm collects objects from these sections according to the section’s colour also the robot arm can organize objects in sections according to the section’s colour.

Crossref (1)
Crossref
Publication Date
Thu Nov 17 2016
Journal Name
International Journal Of Computer Applications
Colour Recognizing Robot Arm Equipped with a CMOS Camera and an FPGA
...Show More Authors

In this paper a system is designed on an FPGA using a Nios II soft-core processor, to detect the colour of a specific surface and moving a robot arm accordingly. The surface being detected is bounded by a starting mark and an ending mark, to define the region of interest. The surface is also divided into sections as rows and columns and each section can have any colour. Such a system has so many uses like for example warehouses or even in stores where their storing areas can be divided to sections and each section is coloured and a robot arm collects objects from these sections according to the section’s colour also the robot arm can organize objects in sections according to the section’s colour.

View Publication
Publication Date
Tue Aug 27 2024
Journal Name
Diagnostics
Accuracy of Gingival Crevicular Fluid Biomarkers of MMP8, TIMP1, RANK, RANKL, and OPG in Differentiating Symptomatic and Asymptomatic Apical Periodontitis
...Show More Authors

Apical periodontitis (AP) is the most prevalent chronic inflammatory disease of the teeth. Bone resorption dynamics in symptomatic and asymptomatic AP are still unrecognized. This study examined different inflammatory markers within gingival crevicular fluid, including matrix metalloproteinases 8 (MMP8), tissue inhibitors of metalloproteinases 1 (TIMP1), receptor activator of nuclear factor κB (RANK), its ligand (RANKL), and osteoprotegerin (OPG), to be used in comparing symptomatic apical periodontitis (SAP) and asymptomatic apical periodontitis (AAP) versus healthy teeth. Subjects with SAP, AAP, and a control group were recruited and GCF samples were collected by Periopaper strips. Clinical and radiographical measures were used f

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Acta Facultatis Medicae Naissensis
Malignant bone tumors in pediatric age groups in Iraq
...Show More Authors

Introduction/Aim. Roughly six percent of all malignancies diagnosed in children are malignant bone tumors. They have a dramatic effect on psychological status of children and their families. The aim of the study was to analyze the clinico-pathological features of bone tumors in Iraqi children and to assess response to treatment, outcome, and survival. Patients and methods. Over an eleven-year period, a retrospective study was done for children with bone tumors conducted on patients data that included a battery of pre-treatment investigations including a complete blood count, serum electrolyte, hepatic, and renal profile, bone marrow aspirate and biopsy, fine-needle aspiration, and imaging studies. Results. Data of 41 children with b

... Show More
View Publication
Scopus Clarivate Crossref