Background:Fractures of patella constitute 1% of all fractures. Various techniques have been described for internal fixation of patella fractures. Superiority of one technique over the other has long been debated. Objective:We reviewed a series of seventy patients with transverse or comminuted fractures of patella treated with cerclage and tension band wiring technique to assess if it had any advantages over k. wires and tension band wiring technique. Type of the study:Retrospective study.Methods; Seventy patients with displaced patella fracture, with a mean age of 47 years (range 13-75) were divided into two groups :group A 36 patients were treated with cerclageand tension bands technique ,and group B 34 patients were fixed by 2 K. wires and tension bands technique. Clinical outcome was assessed using the system of Bostman score. Range of motion and evidence of radiological union were assessed at regular follow-ups. Results; All patients in group A gained Excellent result and good result, while only one patient gained poor result in group B . One patient (2.8%) developed superficial infection in group A and three patients( 8.8% ) developed superficial infection in group B. All fractures had united at the end of 10 weeks. Twenty two patients (31.4%) underwent a second surgery for wire removal; 5 cases in group A ( 13.9 % ) two of them due to implant related complications and 15 ( 44.1%) patients for group B mainly due to pain and interference with daily activity. Malunion or non-union was not noted in any of the cases. . Conclusion; The advantages of the cerclage and tension bands technique for fixation of displaced patella fracture are early mobilization, elimination of k-wire related complications, and ease of use in comminuted fracture pattern as well and a lower reoperation rates as compared to other method of fixation by 2 K. wires and tension bands technique. We strongly recommend its use in cases of displaced comminuted transverse fractures of patella
Zeolite Y nanoparticles were synthesized by sol - gel method. Dffirent samples using two silica sources were prepared.
Sodium metasilicate (Na2SiO3) (48% silica) and silicic acid silica (H2SiO3) (75% silica) were employed as silica
source and aluminum nitrate (Al(NO3)3.9H2O) was the aluminum source with tetrapropylammonium hydroxide
(TPAOH) as templating agent.
The synihesized-samples were characterized by X-ray diffraction, showed the requirement of diffirent aging time for
complete crystallization to be achieved. Transmission Electronic Microscope (TEM) images, showed the particles were
in the same range of 30 - 75 nm. FT-IR spectroscory, showed the synthesized samples having the zeolite Y crystal
properties. The i
Objectives: This study explored knowledge, attitude, and practice of infection control by dental students at College of Dentistry/ University of Baghdad, Iraq. Material and Methods: Three hundred dental students participated in this study. A self administrated questionnaire with 21 close ended questions related to use of personal protective equipments, infection control awareness, vaccination status, percutaneous exposures, and attitude towards treatment of patients with hepatitis B (HBV)/ or human immunodeficiency virus (HIV) was distributed to dental students. Data were analyzed using Statistical Package for Social Sciences (SPSS) version 21. Fisher exact and Chi-square test were used with significance level set to 0.05. Results: The
... Show Morein this paper copper oxide (cuO thin films were prepared by the method of vacum thermal evaporation a pressure.
New simple and sensitive spectrophotometric methods for the determination of paracetamol in aqueous medium were developed. The first method is based on coupling of paracetamol with p-amino-2-hydroxy sodium benzoate (AHB) in the presence of sodium periodate, as oxidizing agent, to form a brownish-orange compound which shows a λmax at 470 nm. The molar absorptivity (εmax) of the colored product was found to be (3371) l. mole1. cm-1 and Sandel’s index 0.0449 μg. cm-2. The method follows Beer’s law in the concentration range of 12.5-500.0 μg of paracetamol in a final volume of 25 ml (0.5-20.0) μg. ml-1 with relative standard deviation percent (RSD%) ranged between 0.26-4.71% and accuracy, expressed by recovery percent, 95-106% for five
... Show MoreThis work involves separating and studying the aminoacylase-1 (ACY1) of amniotic fluid from healthy pregnant, mainly one peak with higher activity has been isolated by DEAE-Cellulose ion exchange from the proteinous supernatant produced by deposition of proteins using ammonium sulfate (65%) after dialysis. The purification folds reaching to 19 folds also gave one protein peak when injected into the gel filtration column, a high ACY1 purity was obtained, with 38 folds of purification. It was found that the molecular weight of the isolated ACY1 was up to 46698 Dalton when using gel chromatography technique.The effect of ACY1 isolate was studied on rats with oxidative stress caused by lead acetate(LA) at 40 mg / kg body weight and compare
... Show MoreDenture cleansing is an essential step that can stop cross‑contamination and adds to the health of the patient, denture durability, and the general quality of life. A disinfection technique must be practical and devoid of damaging effects on the material's properties used to construct the denture base. The main aim of this study is to evaluate the effect of three concentrations of electrolyzed water denture cleanser on heat cure acrylic and polyamide after immersion in electrolyzed water. The evaluation is based on their efficacy on surface hardness, wettability, and color stability compared with one submerged in distilled water as a control group. The method consists of eighty samples of heat-cured acrylic and polyamide material.
... Show MoreIn this paper, Pentacene based-organic field effect transistors (OFETs) by using different layers (monolayer, bilayer and trilayer) for three different gate insulators (ZrO2, PVA and CYEPL) were studied its current–voltage (I-V) characteristics by using the gradual-channel approximation model. The device exhibits a typical output curve of a field-effect transistor (FET). Source-drain voltage (Vds) was also investigated to study the effects of gate dielectric on electrical performance for OFET. The effect of capacitance semiconductor in performance OFETs was considered. The values of current and transconductance which calculated using MATLAB simulation. It exhibited a value of current increase with increasing source-drain voltage.
The removal of congo red (CR) is a critical issue in contemporary textile industry wastewater treatment. The current study introduces a combined electrochemical process of electrocoagulation (EC) and electro-oxidation (EO) to address the elimination of this dye. Moreover, it discusses the formation of a triple composite of Co, Mn, and Ni oxides by depositing fixed salt ratios (1:1:1) of these oxides in an electrolysis cell at a constant current density of 25 mA/cm2. The deposition ended within 3 hours at room temperature. X-ray diffractometer (XRD), field emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), and energy dispersive X-ray (EDX) characterized the structural and surface morphology of the multi-oxide sedim
... Show More