In this paper, a fast lossless image compression method is introduced for compressing medical images, it is based on splitting the image blocks according to its nature along with using the polynomial approximation to decompose image signal followed by applying run length coding on the residue part of the image, which represents the error caused by applying polynomial approximation. Then, Huffman coding is applied as a last stage to encode the polynomial coefficients and run length coding. The test results indicate that the suggested method can lead to promising performance.
This study relates to the estimation of a simultaneous equations system for the Tobit model where the dependent variables ( ) are limited, and this will affect the method to choose the good estimator. So, we will use new estimations methods different from the classical methods, which if used in such a case, will produce biased and inconsistent estimators which is (Nelson-Olson) method and Two- Stage limited dependent variables(2SLDV) method to get of estimators that hold characteristics the good estimator .
That is , parameters will be estim
... Show MoreThe digital image with the wavelet tools is increasing nowadays with MATLAB library, by using this method based on invariant moments which are a set of seven moments can be derived from the second and third moments , which can be calculated after converting the image from colored map to gray scale , rescale the image to (512 * 512 ) pixel , dividing the image in to four equal pieces (256 * 256 ) for each piece , then for gray scale image ( 512 * 512 ) and the four pieces (256 * 256 ) calculate wavelet with moment and invariant moment, then store the result with the author ,owner for this image to build data base for the original image to decide the authority of these images by u
... Show MoreCeftriaxone sodium were one of the widely antibacterial drugs used. Azo dye derivatization of diazonium salt that formed via the reaction between ceftriaxone with hydrochloric acid and sodium nitrite was developed for the on-research drug analysis then coupling with each one 2,5-dimethylphenol (2,5-DMP) and 4-tertbutylphenol (4-TBP) respectively in the alkaline media. The developed diazonium coupling methods include an optimization study. The results show a limit of detection and limit of quantification 0.482, 0.284 µg/mL, and 1.607, 0.945 µg/mL using 2,5-DMP and 4-TBP reagents respectively. Moreover, the recovery % obtained was 100.89%, and 103.37% at linear concentration range 3.0 – 50, and 10 – 30 µg/mL, with mo
... Show MoreThe purpose of this work is to concurrently estimate the UVvisible spectra of binary combinations of piroxicam and mefenamic acid using the chemometric approach. To create the model, spectral data from 73 samples (with wavelengths between 200 and 400 nm) were employed. A two-layer artificial neural network model was created, with two neurons in the output layer and fourteen neurons in the hidden layer. The model was trained to simulate the concentrations and spectra of piroxicam and mefenamic acid. For piroxicam and mefenamic acid, respectively, the Levenberg-Marquardt algorithm with feed-forward back-propagation learning produced root mean square errors of prediction of 0.1679 μg/mL and 0.1154 μg/mL, with coefficients of determination of
... Show MoreIn this paper flotation method experiments were performed to investigate the removal of lead and zinc. Various parameters such as pH, air flow rate, collector concentrations, collector type and initial metal concentrations were tested in a bubble column of 6 cm inside diameter. High recoveries of the two metals have been obtained by applying the foam flotation process, and at relatively short time 45 minutes . The results show that the best removal of lead about 95% was achieved at pH value of 8 and the best removal of zinc about 93% was achieved
at pH value of 10 by using 100 mg/l of Sodium dodecylsulfate (SDS) as a collector and 1% ethanol as a frother. The results show that the removal efficiency increased with increasing initial m