Ultrasound has been used as a diagnostic modality for many intraocular diseases, due its safety, low cost, real time and wide availability. Unfortunately, ultrasound images suffer from speckle artifact that are tissue dependent. In this work, we will offer a method to reduce speckle noise and improve ultrasound image to raise the human diagnostic performance. This method combined undecimated wavelet transform with a wavelet coefficient mapping function: where UDWT used to eliminate the noise and a wavelet coefficient mapping function used to enhance the contrast of denoised images obtained from the first component. This methods can be used not only as a means for improving visual quality of medical images but also as a preprocessing module for computer-aided detection/diagnosis systems to improve the performance of screening and detecting regions of interest in images. The proposed method is experimentally evaluated via 60 ultrasound images of eye. It is demonstrated that the proposed method can further improve the image quality of ocular ultrasound; the results reveal the effectiveness and superiority of the proposed method.
Mass transfer was studied using a rotating cylinder electrode with different lengths of legs acting as turbulence promoters. Two types of rotating cylinder ,made of brass, were examined : an enhanced cylinder one, with four rectangular extensions 10 mm long, 10 mm wide, and 1mm thick, and an enhanced cylinder two with four longitudes 30 mm long,10 mm wide, and 1mm thick. The best performance was obtained for enhanced cylinder two at low rotation speeds while enhanced cylinder one was realized at high rotation speeds. The mass transfer enhancement as compared with a normal rotating cylinder electrode, devoid of promoters, is 53% or 58% higher. The enhancement percentage decreased as rotation speeds increased further, since, seemingly, ful
... Show MoreBackground: Menstrual problems with all manifestations ranging from life-threatening bleeding to amen- orrhea are considered patterns of abnormal uterine bleeding (AUB), which is until now a popular reason for referral to the gynaecologic clinic and requires a special diagnostic tool. Objective: To assess the accuracy of hysteroscopy in diagnosing endometrial pathologies and to compare it with sonographic and histopathologic reports. Patients and Methods: A prospective study conducted in the Baghdad Teaching Hospital on 60 Iraqi females having varying complaints from abnormal uterine bleeding in pre- and post-menopausal women, infertility, and chronic pelvic pain with normal or abnormal ultrasound findings. Office hysteroscopy was done and
... Show MoreThis study was conducted to evaluate the efficacy of different techniques for extraction and purification of Tomato yellow leaf curl virus (TYLCV). An isolate of the virus free of possible contamination with other viruses infecting the same host and transmitted by the same vector Bemisia tabaci Genn. was obtained. This was realized by indicator plants and incubation period in the vector. Results obtained revealed that the virus infect Nicotiana glutinosa without visible symptoms, while Nicotiana tabaccum var. White Burley was not susceptible to the virus. The incubation period of the virus in the vector was found to be 21 hrs. These results indicate that the virus is TYLCV. Results showed that Butanol was more effective in clarification the
... Show MoreHydromorphometric analysis as a method is considered one of the most reliable and used methods in solving hydrological problems. Where it is possible to know the volume of runoff and the rest of the elements that enter into the water balance. Geographical Information System and Remote Sensing is the technique that used the hydro-morphometric analysis of the Wadi Al-Mohammadi basin. Wadi Al-Mohammadi, located in the Western Desert, is one of the main valleys that flow into the Euphrates River. It is considered an important basin, because of its many characteristics, including its relatively large area and the amount of water drained through, which is used mainly in watering livestock and agriculture, in addition to industrial purposes suc
... Show MoreIn this study, industrial fiber and polymer mixtures were used for high-speed impact (ballistic) applications where the effects of polymer (epoxy), polymeric
mixture (epoxy + unsaturated polyester), synthetic rubber (polyurethane), Kevlar fiber, polyethylene fiber (ultra High molecular weight) and carbon fiber.
Four successive systems of samples were prepared. the first system component made of (epoxy and 2% graphene and 20 layer of fiber), then ballistic test was
applied, the sample was successful in the test from a distance of 7 m. or more than, by using a pistol personally Glock, Caliber of 9 * 19 mm. The second
system was consisting of (epoxy, 2% graphene, 36 layers of fiber and one layer of hard rubber), it was succeeded
In the present study, an attempt has been to develop a new water quality index (WQI) method that depends on the Iraqi specifications for drinking water (IQS 417, 2009) to assess the validity of the Euphrates River for drinking by classifying the quality of the river water at different stations along its entire reach inside the Iraqi lands. The proposed classifications by this method are: Excellent, Good, Acceptable, Poor, and Very poor. Eight water quality parameters have been selected to represent the quality of the river water these are: Ion Hydrogen Concentration (pH), Calcium (Ca), Magnesium (Mg), Sodium (Na), Chloride (Cl), Sulphate (SO_4), Nitrate (NO_3), and Total Dissolved Solids (TDS). The variation of the water quality parameters
... Show MoreIn the present study, an attempt has been to develop a new water quality index (WQI) method that depends on the Iraqi specifications for drinking water (IQS 417, 2009) to assess the validity of the Euphrates River for drinking by classifying the quality of the river water at different stations along its entire reach inside the Iraqi lands. The proposed classifications by this method are: Excellent, Good, Acceptable, Poor, and Very poor. Eight water quality parameters have been selected to represent the quality of the river water these are: Ion Hydrogen Concentration (pH), Calcium (Ca), Magnesium (Mg), Sodium (Na), Chloride (Cl), Sulphate (SO_4), Nitrate (NO_3), and Total Dissolved Solids (TDS). The variation of the water quality p
... Show More