A simple, accurate and rapid method for separation and determination of most commonly usedinsecticides in Iraq [thiamethoxam (Thi), imidacloprid (Imi), indoxacarb (Ind), and abamectin (Aba)] ispresented. The separation was performed by gradient reversed-phase high performance liquidchromatography on a C18 stationary phase column. The method was developed and validated. The-1mobile phase was a mixture of acetonitrile and water using gradient flow. The flow rate was 1.0 mL min .The optimum temperature of separation was 25 ºC. The detection was performed at multiple wavelengths.The analysis time was up to 10.5 minutes with retention times of 3.221, 3.854, 6.385, and 9.452 min for-1the studied insecticides. The linearity was in the range of 0.1-200 μg mL . The proposed method wasapplied for the quantitative determination of these insecticides in their pure form and in differentcommercial formulations with little interference of additives
This approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo
... Show MoreA simple and rapid spectrophotometric method for the determination of sulphite SO3-2 is described. The method is based on the rapid reduction of known amount of chromate CrO4-2 in the presence of sulphite in acidic medium of 2N H2SO4. The amount of excess of chromate was measured after it reactions with 1,5-diphenylcarbazide which finally gives a pink-violet, water soluble and stable complex, which exhibit a maximum absorption at 542 nm. Beer's law was obeyed in the concentration range from 0.004-6.0 µg of sulphite in a final volume of 25 ml with a molar absorbtivity of 4.64×104 l.mol-1.cm-1, Sandal's sensitivity index of 0.001724 ?g .cm-2 and relative standard deviation of ±0.55 - ±0.83 depending on the concentration level. The present
... Show MoreA simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations
... Show MoreAlterations of trace element concentrations adversely affect biological processes and could promote carcinogenesis. Trace element deficiency or excess is implicated in the development or progression of some cancers like colorectal cancer. The aim of the present study was to compare the serum copper (Cu) and zinc (Zn) concentrations in patients with colorectal cancer from Iraqi male patient with those of healthy subjects. During the period of March 2015 until august 2015, a total of 25 patients with metastatic colon cancer and 20 healthy volunteers were enrolled from the Al-Kadhimia Teaching Hospital after the diagnosis using a histopathological examination for the malignant tumor; their age was between (38-60) years. Higher
... Show MoreAlterations of trace element concentrations adversely affect biological processes and could promote carcinogenesis. Trace element deficiency or excess is implicated in the development or progression of some cancers like colorectal cancer. The aim of the present study was to compare the serum copper (Cu) and zinc (Zn) concentrations in patients with colorectal cancer from Iraqi male patient with those of healthy subjects. During the period of March 2015 until august 2015, a total of 25 patients with metastatic colon cancer and 20 healthy volunteers were enrolled from the Al-Kadhimia Teaching Hospital after the diagnosis using a histopathological examination for the malignant tumor; their age was between (38-60) years. Higher levels o
... Show MoreThis study was aimed to determine bone formation markers (OST and BALP) and lysyl oxidase in diabetes and non-diabetes Iraqi acromegaly patients in addition to find the relationship among these parameters. The present study conducted 60 acromegalic patients (30 diabetes & 30 non diabetes) attending National Diabetes Center / AL-Mustansiriya University/Baghdad, and 30 healthy individuals as a control group aged (35-60) years. All patients were administrated Sandostatin drug, and they were diagnosed by physician in the hospital.FBG, GH, IGF-1, OST, BALP, and LOX were determined in all groups. The results showed a highly significant rise in all parameters (GH, IGF-1, FBG, OST, BALP, and LOX values in serum of all pati
... Show MoreBackground: Prosthodontists estimated the parallelism of the occlusal plane to different anatomical landmarks, which was somewhat arbitrary and depended mainly on their vision. The aim of this research was to assess the degree of accuracy of prosthodontists in determining the parallelism of two lines. This research was aimed to assess which technique would be more accurate for the prosthodontist to distinguish parallelism; the comparison of the occlusal plane with the interpupillary line or with the inferior border of the earlobes. Materials and methods: Twenty eight prosthodontic specialists were included in this research. Illustrations of two lines with different tilts were presented to the participants to distinguish whether parallel or
... Show MoreMefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen
... Show More