Microfluidic devices provide distinct benefits for developing effective drug assays and screening. The microfluidic platforms may provide a faster and less expensive alternative. Fluids are contained in devices with considerable micrometer-scale dimensions. Owing to this tight restriction, drug assay quantities are minute (milliliters to femtoliters). In this research, a microfluidic chip consisting of micro-channels carved on substrate materials built using an Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters influence the chip’s width, depth, and roughness. To have a regular channel surface, and low roughness, the laser power (60 W), with scanning speed (250 m/s), allows us to obtain microchannels with a minimum diameter of width (450 µm), depth of the channels was 89.4 µm and( Arithmetic Average Roughness Ra=2.3), (Relative roughness, Ɛ=5%) surface roughness with high accuracy and good surface quality. The functionalized multiwalled carbon nanotubes (F-MWCNTs) were used to enhance the drug signal to detect tiny Augmentin concentrations. In this work, laser microfluidic sensors have high accuracy in Augmentin detection compared to the traditional method(UV-VIS) spectrophotometer with LOD equal to 250 nM, 1 µM respectively.
A field experiment was conducted in an agricultural field in Al-Hindia district, Karbala governorate in a silty clay soil during the year 2020. The research included a study of two factors, the first is the depth of plowing at two levels, namely 13 and 20 cm, which represented the main blocks. The second is the tire inflation pressure at two levels, namely (70 and 140 kPa), which represented the secondary blocks. Slippage percentage, field efficiency, leaf area, and 300 grain weight were studied. The experiment was carried out using a split-plot system under a Randomized complete block design, at three replications. The tillage depth of 13 cm exceeds/transcend by giving it the least slippage of (11.01%), the highest field efficiency of (50.
... Show MorePlumbago (Plumbaginaceae) is a genus of 10-20 species of flowering plants used in traditional Indian medicine, native to warm temperature to tropical regions of the world. The roots of Plumbago europaea, the Iraqi species of Plumbago, have been used for the treatment of cancer, rheumatoid arthritis, and dysmenorrhea. The main active constituents from dried powdered leaves and roots of Plumbago europaea were extracted by Soxhlet apparatus using ethyl acetate, the main active constituent was characterized by spectroscopic analysis (IR, 1H NMR, and 13C NMR) as plumbagin. Quantitative and qualitative study of plumbagin in the roots and leaves extracts was carried out by HP
... Show MoreIn this paper to isolate and study the properties of the cyclooxygenase-2 (EC: 1.14.99.1) enzyme in the blood of a patient suffering from rheumatoid arthritis and study the effect of natural products of the Soapwort on the activity of purified enzyme. The study involves taking 30 ml of blood from an adult woman 40 years old, who suffers from rheumatoid arthritis disease for 13 years. Serum is separated and subjected to a series of purification processes including: precipitation by ammonium sulfate, filtration by centrifugation radiator, dialysis in presence of ammonium bicarbonate, separation using the technology of ion exchange, lipholization and then estimating approximate molecular weight of the enzyme using gel filtration techni
... Show MoreAnalyzing plantar pressure trajectories is crucial for assessing foot behavior in dynamic gait stability. We propose the identification of foot symmetry and the detection of deformities by analyzing the trajectories of the center of pressure (CoP) and peak pressure (PP). First, using a foot pressure mapping system, plantar pressure data are acquired during a normal gait cycle. After the data have been acquired, post processing extracts both the CoP and PP trajectories over the spatiotemporal domain of foot motion for each foot independently. For this purpose, we used the optical flow technique which accurately estimates the direction of foot motion. The extracted trajectories of each foot are then segmented into, the medial and lateral regi
... Show MorePower-electronic converters are essential elements for the effective interconnection of renewable energy sources to the power grid, as well as to include energy storage units, vehicle charging stations, microgrids, etc. Converter models that provide an accurate representation of their wideband operation and interconnection with other active and passive grid components and systems are necessary for reliable steady state and transient analyses during normal or abnormal grid operating conditions. This paper introduces two Laplace domain-based approaches to model buck and boost DC-DC converters for electromagnetic transient studies. The first approach is an analytical one, where the converter is represented by a two-port admittance model via mo
... Show MoreIn this research, an enhancement in lubricating, rheological, and filtration properties of unweighted water-based mud is fundamentally investigated using XC polymer NPs with 0.2gm, 0.5gm, 1gm, 2gm, and 4gm concentrations. Bentonite, that had been used in the preparation of unweighted water-based mud, was characterized using XRF-1800 Sequential X-ray Fluorescence Spectrometer, XRD-6100/7000 X-ray Diffractometer, and Malvern Mastersizer 2000 particle size analyzer, respectively. Lubricating, rheology and filtration properties of unweighted water-based mud were measured at room temperature (35°C) using OFITE EP and Lubricity Tester, OFITE Model 900 Viscometer, and OFITE Low-Pressure Filter Press, respectively. XC Polymer N
... Show MoreAbstract. This work presents a detailed design of a three-jointed tendon-driven robot finger with a cam/pulleys transmission and joint Variable Stiffness Actuator (VSA). The finger motion configuration is obtained by deriving the cam/pulleys transmission profile as a mathematical solution that is then implemented to achieve contact force isotropy on the phalanges. A VSA is proposed, in which three VSAs are designed to act as a muscle in joint space to provide firm grasping. As a mechatronic approach, a suitable type and number of force sensors and actuators are designed to sense the touch, actuate the finger, and tune the VSAs. The torque of the VSAs is controlled utilizing a designed Multi Input Multi Output (MIMO) fuzzy controll
... Show More