Preferred Language
Articles
/
RxYtU4cBVTCNdQwCfUU4
The reliability of using light therapy compared with LASER in pain reduction of temporomandibular disorders: a randomized controlled trial
...Show More Authors
Abstract<sec> <title>Background

Temporomandibular Disorders (TMD) refer to a group of symptoms where pain is the most leading cause to demand a treatment by the patient. Light therapies are of great importance at current times due to its biosafety and non-invasive quality when used for the management of TMD symptoms. This study aimed to evaluate the efficacy of red LED light with low-level LASER in treating TMD patients.

Materials and methods

A double-blind randomized clinical study was conducted and included 60 patients along 3 groups (20 for each group) presented with myofascial pain related to TMD. Patients were randomly divided into 3 groups. Group A were managed by applying the LED light device into the trigger points without switching the device on. A red LED light was given to group B for 5 min at the tender muscles. Group C were treated by using low-level LASER therapy for 30 s. Patients were evaluated for any improvements regarding the pain score, presence of trigger points, and trismus along 4 visits (1 week interval between each visit). Any side effects related to the 2 devices were also assessed.

Results

Both group B and C patients showed a statistically significant improvement in the pain value (P < 0.05) at the 3rd and 4th visits when compared to group A. Regarding tenderness, there was a reduction in the number of trigger points in both study groups; however, the results were insignificant in group B. Statistics showed insignificant differences between group B & C patients regarding pain and number of trigger points at all visits (P > 0.05).

Conclusion

Both LED light and LASER therapies could effectively relieve pain associated with myogenic TMD as there were no important differences between their outcomes. However, the biosafety and lower cost of the LED light device compared to the LASER should also be considered.

Trial Registration This clinical trial was prospectively registered (TCTR ID: TCTR20190507002) on 07/05/2019. URL: http://www.thaiclinicaltrials.org/show/TCTR20190507002

Scopus Crossref
View Publication
Publication Date
Sun Mar 30 2025
Journal Name
Samarra Journal Of Engineering Science And Research
Proposed low Xilinx FPGA power consumption for recursive NOMA applied in optical visible light communication
...Show More Authors

Today the NOMA has exponential growth in the use of Optical Visible Light Communication (OVLC) due to good features such as high spectral efficiency, low BER, and flexibility. Moreover, it creates a huge demand for electronic devices with high-speed processing and data rates, which leads to more FPGA power consumption. Therefore; it is a big challenge for scientists and researchers today to recover this problem by reducing the FPGA power and size of the devices. The subject matter of this article is producing an algorithm model to reduce the power consumption of (Field Programmable Gate Array) FPGA used in the design of the Non-Orthogonal Multiple Access (NOMA) techniques applied in (OVLC) systems combined with a blue laser. However, The po

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Impact of Brix 3000 and conventional restorative treatment on pain reaction during caries removal among group of children in Baghdad city
...Show More Authors

Background: Pain and the usage of local anesthetic agents are still real problem in pediatric dentistry, for these reasons, the use of minimal invasive dentistry (MID) in regard to the patient comfort is important especially for children, anxious and uncooperative patients. Chemomechanical caries removal (CMCR) methods involve the selective removal of the carious dentine hence it avoided the painful removal of the sound dentine and the anxiety resulted due to the vibration of the hand piece which is also decreased thus it appears to be more acceptable and comfortable to the patient. Aims of this study: This study was conducted among group of children to assess and compare the anxiety rating scale (during and after treatment) between the

... Show More
View Publication
Scopus (17)
Crossref (16)
Scopus Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
Blue Organic-Inorganic Light Emitting Diode Based on Electroluminescence CdS Nanoparticle
...Show More Authors

     A hybrid cadmium sulfide nanoparticles (CdSNPs) electroluminescence (EL) device was fabricated by Phase – Segregated Method and characterized. It was fabricated as layers of (ITO/poly-TPD:CdS ) and (ITO/poly-TPD:CdS /Alq3). Poly-TPD is an excellent Hole Transport Layer (HTL), CdSNPs is an emitting layer and Alq3 as electron transport layer (ETL). The EL of Organic-Inorganic Light Emitting Diode (OILED) was studied at room temperature at 26V. This was achieved according to band-to-band transition in CdSNPs. From the I-V curve behavior, the addition of Alq3 layer decreased the transfer of electrons by about 250 times. The I-V behavior for (poly-TPD/CdS) is exponential with a maximum current of 4500 µA. While, the current i

... Show More
Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Wed Oct 21 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of light curing tip distance on the curing depth of bulk fill resin based composites
...Show More Authors

Background: This in vitro study measure and compare the effect of light curing tip distance on the depth of cure by measuring vickers microhardness value on two recently launched bulk fill resin based composites Tetric EvoCeram Bulk Fill and Surefil SDR Flow with 4 mm thickness in comparison to Filtek Z250 Universal Restorative with 2 mm thickness. In addition, measure and compare the bottom to top microhardness ratio with different light curing tip distances. Materials and Method: One hundred fifty composite specimens were obtained from two cylindrical plastic molds the first one for bulk fill composites (Tetric EvoCeram Bulk Fill and Surefil SDR Flow) with 4 mm diameter and 4 mm depth, the second one for Filtek Z250 Universal Restorative

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 12 2007
Journal Name
Iraqi Journal Of Laser
Incident Laser Power and Concentration Effects on the Fluorescence of DCM Dye in PMMA Polymer
...Show More Authors

Incident laser power and concentration effects on fluorescence emission from DCM dye in PMMA polymer have been investigated. Different concentrations of the dye were used. It was found that the fluorescence intensity increased with increasing of the concentration of the dye, with a red shift. In addition, it was found that the fluorescence intensity increased with the increase of the incident laser power I0.

View Publication Preview PDF
Publication Date
Thu Jan 06 2022
Journal Name
Chemical Papers
A solvent collection technique using dispersive liquid–liquid microextraction coupled with spectrophotometry for the trace determination of folic acid in pure, dosage forms and flaxseed
...Show More Authors

A simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl

... Show More
View Publication
Scopus (8)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Rsc Advances
Development of a multi-source blue light irradiation platform for photometric quantification of ascorbic acid <i>via</i> continuous absorbance quenching of the ferric–thiocyanate complex
...Show More Authors

Diagram of CFIA system: (A) Fe 3+ line; (B) SCN − line; (C) A.A carrier; (D) sample valve; (E) mixing/reaction coil quenched by A.A; (F) blue LED detector.

View Publication Preview PDF
Scopus (5)
Crossref (6)
Scopus Crossref
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Establish Growth Curve in Light of Body Mass Index for Infertile Women in Baghdad City
...Show More Authors

Objective: To establish growth curve for a sample of infertile women and to assess Body Mass Index.
Methodology: Non-probability (purposive sample) of (100) infertile women, who visit Kamal Al-Samaraee
Hospital/ fertility and IVF center . The data are collected through the use of constructed questionnaire, which
consists of two parts. Part 1: consists of (5) items about demographic characteristics, part 2: consists of (4) items
about reproductive status, descriptive statistical analysis procedures (frequency, percentage, Contingency
coefficients, polynomial cube order).
Results: Revealed that the infertile women in the study group had decrease in their Body Mass Index with aging
(with increase of infertility duration

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Effect of CO2 Laser Irradiation on the Topographic and Optical Properties of CdO Thin Films
...Show More Authors

     In this study, cadmium oxide (CdO) was deposited on glass bases by thermal chemical spraying technique at three concentrations (0.05, 0.1, 0.15) M and then was irradiated by CO2 laser with 10.6 μm wave length and 1W power. The results of the atomic force microscope AFM test showed that the surfaces of these CdO thin films were homogenous and that the laser irradiated effect resulted in decreasing the roughness of the surface as well as the heights of the granular peaks, indicating a greater uniformity and homogeneity of the surfaces. The optical properties were studied to determine laser effect. The results of optical tests of these thin films showed that the photoluminescence spectra and absorption s

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Dec 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of Solvent Extraction of Light Lubricating Oil on Viscosity Index and Chemical Composition
...Show More Authors

An investigation was conducted for the improvement of viscosity index of light lubricating oil fraction (40 stock)
obtained from vacuum distillation unit of lube oil plant of Daura Refinery, using solvent extraction process.
In this study furfural solvent was used to extract the undesirable materials which reduce the viscosity index of raw
lubricating oil fraction.
The studied effecting variables of extraction were extraction temperature range from 70 to 110°C, and solvent to oil
ratio range from 1:1 to 4:1 (wt/wt).
The n-d-M method was used for calculation of carbon distribution and structural group analysis of the raffinate
produced from furfural extraction.
Also the three component phase diagram for a mixed-ba

... Show More
View Publication Preview PDF