Our aim was to investigate the changes in the myocardium stiffness index for patients suffering from systemic hypertension, and to assess their left ventricular performance. We studied 263 hypertensive patients and 166 healthy subjects as a control group. By using conventional Doppler echocardiography, the following parameters were measured—Left ventricular end diastolic diameter, left ventricular end systolic diameter, transmitral early velocity, isovolumic relaxation time, and isovolumic contraction time. Tissue Doppler imaging (TDI) was used in the measurements of the early mitral annular velocity (Ea) and the diastolic stiffness was obtained by calculating the ratio E\Ea\LVIDd. Index myocardial performance (IMP) was calculated according to following equation (IVCT + IVRT)/ET for both the control group and hypertensive group. Results reveal that the differences in the average value of transmitral early filling velocity (E) between patients and control groups for age range (20 - 49) and (50 - 80) were (−1.91%) and (−3.69%) respectively with p value >0.05 for both groups, and the changes in LVIDd between patients and control groups were 0.42% and 1.29% for age ranges (20 - 49) and (50 - 80) respectively with p value >0.05 for both age groups. A significant difference in IMP between patients and controls has also been observed and the changes were 29.54% and 30.43% for age range (20 - 49) and (50 - 80) respectively with p value <0.05 for both groups. The mean values for E/Ea ratio and for the measured LV stiffness index were significantly higher in hypertensive patients compared with control group (p value < 0.05) for both age groups. In conclusion, LV myocardial diastolic stiffness index and IMP are increased in hypertensive patients.
An improved Metal Solar Wall (MSW) with integrated thermal energy storage is presented in this research. The proposed MSW makes use of two, combined, enhanced heat transfer methods. One of the methods is characterized by filling the tested ducts with a commercially available copper Wired Inserts (WI), while the other one uses dimpled or sinusoidal shaped duct walls instead of plane walls. Ducts having square or semi-circular cross sectional areas are tested in this work.
A developed numerical model for simulating the transported thermal energy in MSW is solved by finite difference method. The model is described by system of three governing energy equations. An experimental test rig has been built and six new duct configurations have b
Numerical Investigation was done for steady state laminar mixed convection and thermally and hydrodynamic fully developed flow through horizontal rectangular duct including circular core with two cases of time periodic boundary condition, first case on the rectangular wall while keeping core wall constant and other on both the rectangular duct and core walls. The used governing equations are continuity momentum and energy equations. These equations are normalized and solved using the Vorticity-Stream function and the Body Fitted Coordinates (B.F.C.) methods. The Finite Difference approach with the Line Successive Over Relaxation (LSOR) method is used to obtain all the computational results the (B.F.C.) method is used to generate th
... Show MoreFlexible job-shop scheduling problem (FJSP) is one of the instances in flexible manufacturing systems. It is considered as a very complex to control. Hence generating a control system for this problem domain is difficult. FJSP inherits the job-shop scheduling problem characteristics. It has an additional decision level to the sequencing one which allows the operations to be processed on any machine among a set of available machines at a facility. In this article, we present Artificial Fish Swarm Algorithm with Harmony Search for solving the flexible job shop scheduling problem. It is based on the new harmony improvised from results obtained by artificial fish swarm algorithm. This improvised solution is sent to comparison to an overall best
... Show MoreThis paper reports a numerical study of flow behaviors and natural convection heat transfer characteristics in an inclined open-ended square cavity filled with air. The cavity is formed by adiabatic top and bottom walls and partially heated vertical wall facing the opening. Governing equations in vorticity-stream function form are discretized via finite-difference method and are solved numerically by iterative successive under relaxation (SUR) technique. A computer program to solve mathematical model has been developed and written as a code for MATLAB software. Results in the form of streamlines, isotherms, and average Nusselt number, are obtained for a wide range of Rayleigh numbers 103-106 with Prandtl number 0.71
... Show MoreThe study aimed to assess the expression of CD49d and CD26 in newly diagnosed CLL patients and find their correlation with clinical Binet stage, and other clinical parameters. This study was conducted on 51 newly diagnosed CLL patients based on lymphocyte count > 5×109/L and immunophenotyping. The expression of CD49d, and CD26 were investigated using eight-color flow cytometer. The expression of CD49d and CD26 were detected in 56.9 %, 68.8 % of CLL patients, respectively. The correlation between CD49d expression and CD26 expression was statistically significant (p < 0.001) with high concordance rate between them. The positive expression of both CD49d and CD26 had statistically significant association with clinical Binet staging (p < 0.001,
... Show MoreMy research to study the processes of the creation of shapes and encrypt any encryption in design forms and contents of computer technology as the creative property of definable and renewal, change and transformation process of transformative theme of shape, form and content encryption process in textile designs lets us know the meaning or substance which may be invisible to the encryption in the digital design of fabrics is a recruitment ideas modern and refined through a technique to accomplish the work of a beautiful audiences with novelty and innovation. The search includes four chapters:1Chapter I deal with the problem of research and its current research (form and content encryption with digital designs in women's contemporary fabr
... Show MoreNumerical study is adapted to combine between piezoelectric fan as a turbulent air flow generator and perforated finned heat sinks. A single piezoelectric fan with different tip amplitudes placed eccentrically at the duct entrance. The problem of solid and perforated finned heat sinks is solved and analyzed numerically by using Ansys 17.2 fluent, and solving three dimensional energy and Navier–Stokes equations that set with RNG based k−ε scalable wall function turbulent model. Finite volume algorithm is used to solve both phases of solid and fluid. Calculations are done for three values of piezoelectric fan amplitudes 25 mm, 30 mm, and 40 mm, respectively. Results of this numerical study are compared with previous b
... Show MoreDBN Rashid, JOURNAL OF XI'AN UNIVERSITY OF ARCHITECTURE & TECHNOLOGY, 2020
Objectives: This study aimed to evaluate the therapeutic potential effects of ascorbic acid or and pyridoxine on diabetic renal microalbumiuria. Methods: This was a cross-sectional study on patients with diabetes mellitus at Al-Yarmouk teaching hospital from January to December 2012, Iraq-Baghdad. Twenty one patients with diabetes mellitus (D.M), 8 IDDM and 13 IDDM were selected from, the duration of disease were ranged from 2-12 years for both type (10 females and 11males) and all enrolled patients ages were ranged from 28-65years. The concentration of total protein in urine was calculated by a biuret colorimetric assay and the urine creatinine level was measured by a modified Jaffe test. Statistical analysis: results are expressed as mean
... Show More