Preferred Language
Articles
/
Jxdi5Y8BVTCNdQwCKICK
EVALUATION AND PERFORMANCE COMPARISON OF MOLD BOARD AND DISC PLOW IN SOILS OF CENTRAL IRAQ
...Show More Authors

The experiment was conducted to evaluate and performance comparison for moldboard and disk plows in central of Iraq in 2011. Three factor were used in this study included Two types of plows included moldboard and disk plows which represented main plot , three forward speeds of the tillage was second factor included 1.85, 3.75 and 5.62 km / h which represented sup plot , and three levels of soil moisture was third factor included 21 , 18 and 14 % to determined data actual plow depth , Practical productivity, Volume of disturbed soil, Field efficiency , Slippage percentage in silt clay loam soil with depth 22 cm were studied in the experiment Split – split plot design under randomized complete block design with three replications using Least Significant Design was used . Mold board plough recorded best practical productivity was 0.3118 ha/hr , volume of disturbed soil was 629.77 m3/hr and field efficiency was 59.85 % , while disc plough recorded higher actual plow depth 21.02 cm and slippage percentage was9.71 % . Increasing forward speeds of the tillage from 1.85 to 3.75 then to 5.62 increasing slippage percentage from 6.39 to 8.26 then to 12.22 % , practical productivity from 0.1421 to 0.2845 then to o.4180 ha/hr and volume of disturbed soil from 299.89 to 592.38 then to 838.24 m3/hr , while decreased actual plow depth from 21.13 to 20.86 then to 20.08 cm and field efficiency from 58.98 to 58.21 then to 57.07 % . with decrease soil moisture from 21 to 18 % decrease actual plow depth from 20.92 to 20.70 cm and slippage percentage from 10.58 to 7.29 % , and increase practical productivity from 0.2712 to 0.2923 ha/hr, volume of disturbed soil from 562.01 to 598.98 m3/hr and field efficiency from 55.94 to 60.31 % . While continues decrease from 18 to 14 % decrease actual plow depth from 20.70 to 20.46 cm, practical productivity from 0.2923 to 0.2811, volume of disturbed soil from 598.98 to 569.52 m3/hr and field efficiency from 60.31 to 58.01 % , and increase slippage percentage from 7.29 to 9.00 % .

Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
The Effect of Fluorine and Hydrogen Concentrations on the Chain Reaction of HF Chemical Laser
...Show More Authors

A numerical investigation has been performed to examine the effect of fluorine concentration on the chain reaction mechanisms and parameters of hydrogen fluoride (HF) chemical laser. The practical difficulties associated with this type of lasers impose that an alternative route might be quite useful. Thus, particular attention was paid to develop a computer program to investigate various processes. The results of this computer simulation program proved their credibility when compared with the little published data. This computer program is called Reaction Rate Simulation Model (RRSM). An entirely new approach to emulate the reaction mechanisms has been followed. The effectiveness of reaction rates in the processes of HF lase

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 30 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Upgrading of Al-Rustamiyah Sewage Treatment Plant Through Experimental and Theoretical Analysis of Membrane Fouling
...Show More Authors

Al-Rustamiyah plant is the oldest and biggest sewage treatment plant in Iraq; it locates in the south of Baghdad city. The plant suffers from serious problems associated with overflow and low capacity. The present work aims to upgrade the heart of biological treatment process through suggesting the use of membrane bioreactor; (MBR). In this work, fouling of membrane during sewage treatment has been analyzed experimentally and theoretically by fouling mechanisms. Aeration has been applied in order to control fouling through producing effective diameters of air bubbles close to the membrane walls. Effect of air flow rate on flux decline was investigated. Hermia's models were used to investigate the fouling mechanisms. The results showed th

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 03 2016
Journal Name
Al-mustansiriyah Journal Of Science
Synthesis and Characterization of Some New Metal Complexes of Ligand [N-(3-acetylphenylcarbamothioyl)-4-chlorobenzamide]
...Show More Authors

A new ligand [N-(3-acetylphenylcarbamothioyl)-4-chlorobenzamide] (CAD) was synthesized by reaction of 4-Chlorobenzoyl isothiocyanate with 3-amino acetophenone, The ligand was characterized by elemental micro analysis C.H.N. S., FT-IR, UV-Vis and 1H,13C- NMR spectra, some transition metals complexes of this ligand were prepared and characterized by FT-IR, UV-Vis spectra, conductivity measurements, magnetic susceptibility and atomic absorption, From obtained results the molecular formula of all prepared complexes were [M(CAD)2(H2O)2]Cl2 (M+2 =Mn, Co, Ni, Cu, Zn, Cd and Hg),the proposed geometrical structure for all complexes were octahedral

Publication Date
Thu Oct 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Influence of the Applied Potential and Temperature on the Electrode position of the Lead Dioxide
...Show More Authors

The excellent specifications of electrodes coated with lead dioxide material make it of great importance in the industry. So it was suggested this study, which includes electrodeposition of lead dioxide on graphite substrate, knowing that the electrodeposition of lead dioxide on graphite studied earlier in different ways.

In this work the deposition process for lead dioxide conducted using electrolytic solution containing lead nitrate concentration 0.72 M with the addition of some other material to the solution, such as copper nitrate, nickel nitrate, sodium fluoride and cetyl trimethyl ammonium bromide, but only in very small concentrations. As for the operating conditions, the effect of change potential and temperature as well

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 28 2023
Journal Name
Baghdad Science Journal
A Comparative Study of the Photostabilization of Polyvinyl Chloride with Nano and Micro Nickel Oxide
...Show More Authors

NiO nanoparticle synthesis by chemical method and characterized by XRD with crystal size 11.72
nm and grain size 13 nm from FESEM image also NiO micro used ,two NiO as an additive to evaluate the
possibility of producing photodegradable polymers, the practical application of solid-phase photocatalytic
degradation of polyvinyl chloride (PVC- NiO composite films) was investigated. PVC has a negative impact
on the environment since its polymer degrades slowly, yet it has a wide range of industrial applications and
the amount used shows no evidence of diminishing use. Thus, a synthesis of modified PVC- NiO micro and
nano has been studied with 0, 50, 100, 150, 200, 250, and 300 (hours) as irradiation time a

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Fri Dec 06 2019
Journal Name
Mechanics Of Advanced Materials And Structures
Finite element modeling of RC gable roof beams with openings of different sizes and configurations
...Show More Authors

View Publication Preview PDF
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Feb 01 2021
Journal Name
International Medical Journal
The Effect of Adding Poloxamer Surfactant on Cleaning Efficiency of NaOCl and NaOH (SEM Study)
...Show More Authors

Objectives: The purpose of this in vitro study was to compare the effect of adding a poloxamer surfactant to the irrigant solutions on its cleaning efficiency. Design: In this study the roots of extracted permanent premolar teeth were used and evaluated by using Scanning Electronic Microscopy (SEM). Materials and Method: 72 human single tooth of permanent premolar (8 for each group) were used in this in vitro study. Roots after sectioning at cervical area to get 15 mm were embedded in a plastic container filled with impression silicon, then instrumented with ProTaper rotary instruments till size F4. Each group (8 root) were irrigated with one of the nine solutions used in study: three concentrations of NaOH [5% (A1), 2.5%(A2), 0.5%(A3)], th

... Show More
Preview PDF
Publication Date
Fri Apr 04 2025
Journal Name
European Journal Of Dentistry
The Effectiveness of Conventional and Advanced Aligning Archwires: The Insights of Two Randomized Clinical Trials
...Show More Authors
Abstract<p> Objectives This study aimed to compare the clinical effectiveness of four aligning archwires: Superelastic Nickel-Titanium (Superelastic-NiTi), SmartArch, Copper-Nickel-Titanium (Cu-NiTi), and Speed Tubular coaxial-Nickel-Titanium (Tubular coaxial-NiTi), regarding the alignment efficiency, associated perception of pain, and possibility of inducing root resorption.</p><p> Materials and Methods This study includes two randomized clinical trials run in parallel. Patients with 5 to 9 mm of mandibular anterior teeth crowding according to Little's irregularity index (LII) who needed fixed orthodontic appliances without extraction were randomly assigned to four groups of</p> ... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2018
Journal Name
World Journal Of Dentistry
Effect of Mouthwashes on Frictional Properties of Gold-plated and Ordinary Stainless Steel Orthodontic Brackets
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Effects of Sodium Chloride and Sodium Sulphate Solutions on the Output of the Electrochemical Machining
...Show More Authors

Electrochemical Machining is a term given to one of nontraditional machining that uses a chemical reaction associated with electric current to remove the material. The process is depending on the principle of anodic dissolution theory for evaluating material removal during electrochemical process. In this study, the electrochemical machining was used to remove 1 mm from the length of the a workpiece (stainless steel 316 H) by immersing it in to electrolyte (10, 20 and 30 g) of NaCl and Na2SO4 to every (1 litter of filtered water).  The tool used was made from copper. Gap size between the workpiece and electrode is (0.5) mm. This study focuses on the effect of the changing the type and concentration of electroly

... Show More
View Publication Preview PDF