Preferred Language
Articles
/
Jhemh5IBVTCNdQwCW7M0
YIELDS CALCULATIONS FOR POSITRON EMISSION TOMOGRAPHY (PET) FOR NON-STANDARD RADIONUCLIDE
...Show More Authors

The PET scans provide images that pinpoint the anatomic location of abnormal metabolic activity within the body. A radionuclide suitable for labeling a wide range of radiopharmaceuticals for positron emission tomography imaging is used also for local therapy of tumors. Among the possible methods for cyclotron production of radionuclide used in PET. We investigate the proton irradiation to produce the standard radionuclide (15O, 11C,1 3N, 18F) and some non-standard Radionuclide (76Br,124I,60Cu,66Ga,86Y and 89Zr). The total integral yield based on the main published and approved experimental results of excitation functions were calculated.

Preview PDF
Quick Preview PDF
Publication Date
Sat Apr 19 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of bone density after six months from dental implants placement using Computed Tomography
...Show More Authors

Background: Determination of local bone mineral density (BMD) immediately after implant insertion play an important role in implant success rate, may offer comprehensive description of the bone, and give enough information to the surgeon prior to implant insertion and at follow up status. The aim of the present study is to evaluate the changes of local bone density in the dental implant recipient sites by using computerized tomography. Material and method: The sample consisted of (20) dental implants recipient sites, bone density assessment was done twice, immediately after implants insertion and after six months. Results: The mean HU of the bone around the implant insertion site, immediately after implant placement was 552.28 HU, and inc

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 29 2023
Journal Name
Pakistan Journal Of Ophthalmology
Corneal Parameters Measurement in Healthy Subjects Using Scheimpflug and Anterior Segment Optical Coherence Tomography
...Show More Authors

Purpose:  To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design:  Descriptive observational. Place and Duration of Study:  Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods:  A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results:  Mean age was 28.54 ± 6.6 years, me

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jan 25 2021
Journal Name
Journal Of Craniofacial Surgery
Cone Beam Computed Tomography Evaluation of the Morphological Variation and Width in Mandibular Condyle
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Investigation of density and form factor of some F isotopes using Hartree-Fock and shell model calculations
...Show More Authors

Structure of unstable 21,23,25,26F nuclei have been investigated
using Hartree – Fock (HF) and shell model calculations. The ground
state proton, neutron and matter density distributions, root mean
square (rms) radii and neutron skin thickness of these isotopes are
studied. Shell model calculations are performed using SDBA
interaction. In HF method the selected effective nuclear interactions,
namely the Skyrme parameterizations SLy4, Skeσ, SkBsk9 and
Skxs25 are used. Also, the elastic electron scattering form factors of
these isotopes are studied. The calculated form factors in HF
calculations show many diffraction minima in contrary to shell
model, which predicts less diffraction minima. The long tail

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 01 2021
Journal Name
International Medical Journal
Knowledge and Attitude of Iraqi Dentists towards the Use of Cone Beam Computed Tomography in Endodontics: A Questionnaire Study
...Show More Authors

Objective: The aim of this study was to assess the knowledge and attitude of Iraqi dentists towards cone beam computed tomography (CBCT) applications in endodontics by using an online survey. Materials and Methods: A questionnaire, consisting of 31 questions, targeted general dental practitioners and specialists in different dental specialities. A total of 306 participants were included. Data were assessed according to the frequency of distribution and the chi-square test was applied to analyse the difference in responses between two independent groups. Results: Among the participants 63.4% were using digital radiography in their daily practice, and 84% had awareness about CBCT's uses, with higher statistically significant responses among e

... Show More
View Publication Preview PDF
Publication Date
Wed May 31 2023
Journal Name
International Journal Of Advanced Technology And Engineering Exploration
Investigation of phase change characteristics for refrigerant R-134a flow in a double pipe heat exchanger with the use of thermal non-equilibrium model
...Show More Authors

Almost all thermal systems utilize some type of heat exchanger. In a lot of cases, evaporators are important for systems like organic Rankine cycle systems. Evaporators give a share in a large portion of the capital cost, and their cost is significantly attached to their size or transfer area. Open-cell metal foams with high porosity are taken into consideration to enhance thermal performance without increase the size of heat exchangers. Numerous researchers have tried to find a representation of the temperature distribution closer to reality due to the different properties between the liquid and solid phases. Evaporation heat transfer in an annular pipe of double pipe heat exchanger (DPHEX) filled with cooper foam is investigated numerical

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Physics
A Study of the generation of laser soliton from spontaneous emission by ring cavity with carbon nanotube
...Show More Authors

We demonstrate a behavior of laser pulse grows through fiber laser inside and output cavity with a soliton fiber laser based on the multi-wall carbon nanotube saturable absorber (SA), we investigate the effects of a saturable absorber parameter on the mode-locking of a realistic Erbium fiber ring laser. Generalized nonlinear Schrodinger equation including the nonlinear effects as gain dispersion, second anomalous group velocity dispersion (GVD), self phase modulation (SPM), and two photon absorption used to describe pulse evolution. An analytical method has been used to understand and to quantify the role of the SA parameter on the propagation dynamics of pulse laser. We compute the chirp, power, width and phase of the soliton for range

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 01 2021
Journal Name
Nonlienear Optics Quantum Optics
Narrow Emission Linewidth of Highly-Pure Silicon Nitride Nanoparticles in Different Dye Solutions as Random Gain Media
...Show More Authors

In this work, two different laser dye solutions were used to host highly-pure silicon nitride nanoparticles as scattering centers to fabricate random gain media. The laser dye was dissolved in three different solvents (ethanol, methanol and acetone) and the final results were obtained for methanol only. The silicon nitride nanoparticles were synthesized by dc reactive magnetron sputtering technique with average particle size of 35 nm. The random gain medium was made as a solid rod with high spectral efficiency and low production cost. Optical emission with narrow linewidth was detected at 532-534 nm as 9 mg of silicon nitride nanoparticles were added to the 10 -5 M dye solution. The FWHM of 0.3 and 3.52 nm was determined for Rhodamine B and

... Show More
View Publication
Publication Date
Tue Nov 15 2022
Journal Name
Nasaq Journal
Componential Analysis of Hatred Synonymy in the Lexicons of English and Standard Arabic
...Show More Authors

ABSTRACT This paper has a three-pronged objective: offering a unitary set of semantic distinctive features to the analysis of nominal “hatred synonyms” in the lexicon of both English and Standard Arabic (SA), applying it procedurally to test its scope of functionality crosslinguistically, and singling out the closest noun synonymous equivalents among the membership of the two sets in this particular lexical semantic field in both languages. The componential analysis and the matching procedures carried have been functional in identifying ten totally matching equivalents (i.e. at 55.6%), and eight partially matching ones (i.e. at %44.4%). This result shows that while total matching equivalences do exist in the translation of certain Eng

... Show More
View Publication
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
Minimal sternotomy surgery in comparison to standard sternotomy in the coronary bypass Surgery
...Show More Authors

Background Median sternotomy is the gold standard incision for most cardiac operations. However, with the advent of minimal invasive surgery, a new approach emerged in cardiac surgery named mini-sternotomy and has been successfully used to perform a variety of operations.

 The aim of this paper is to present our experience of using mini-sternotomy to harvest the left internal mammary artery (LIMA) for off-pump revascularization of the left anterior descending artery (LAD)

 Methodology Over a 2-year period (October 2012-October 2014), 100 patients underwent coronary artery bypass grafting (CABG) via conventional median sternotomy (CMS) (n=80) and mini-sternotomy (MS) (n=20). The

... Show More
View Publication Preview PDF
Crossref