Preferred Language
Articles
/
Jhemh5IBVTCNdQwCW7M0
YIELDS CALCULATIONS FOR POSITRON EMISSION TOMOGRAPHY (PET) FOR NON-STANDARD RADIONUCLIDE
...Show More Authors

The PET scans provide images that pinpoint the anatomic location of abnormal metabolic activity within the body. A radionuclide suitable for labeling a wide range of radiopharmaceuticals for positron emission tomography imaging is used also for local therapy of tumors. Among the possible methods for cyclotron production of radionuclide used in PET. We investigate the proton irradiation to produce the standard radionuclide (15O, 11C,1 3N, 18F) and some non-standard Radionuclide (76Br,124I,60Cu,66Ga,86Y and 89Zr). The total integral yield based on the main published and approved experimental results of excitation functions were calculated.

Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of alveolar bone height in adolescents utilizing Cone Beam Computed Tomography: a retrospective radiographic analysis
...Show More Authors

Background: To assess the alveolar bone crest level (ABCL) by Cone Beam Computed To-mography (CBCT) and to investigate several variables as predictors for the height of the alveolar bone in adolescents. Materials and methods: Age, sex, and ethnic groups were rec-orded for each patient. CBCT images were used to obtain measurements of the interproximal alveolar bone level from the cementoenamel junction (CEJ) to the alveolar crest. The highest measurement in each sextant was recorded along with any presence of a vertical bone defect or calculus. Results: Total of 720 measurements were recorded for 120 subjects. No vertical bony defects or calculus were observed radiographically. Statistically significant (P< 0.05) differences were observed be

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Dec 22 2024
Journal Name
Journal Of Baghdad College Of Dentistry
A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings
...Show More Authors

Background: The main aim of the present study is to qualify and quantify voids formation of root canals obturated with GuttaCore (GC) and experimental Hydroxyapatite polyethylene (HA/PE) as new carrier-based root canal fillings by using micro computed tomography scan. Materials and methods: In the present study, eight straight single-rooted human permanent premolar teeth are selected and disinfected, then stored in distilled water. The teeth decoronated leaving a root length of 12mm each. The root canals instrumented by using crown down technique and the apical diameter of the root canal prepared to a size # 30/0.04 for achieving standardized measurements. A 5mL of 17% EDTA used to remove the smear layer followed by 5mL of 2.5% NaOCl and r

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 03 2011
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Performance of computed tomography in diagnosis and evaluation of traumatic intracerebral hemorrhage
...Show More Authors

Background: The intracerebral hemorrhage (ICH) can be classified as traumatic and spontaneous. The frontal and temporal lobes are classic sites for traumatic ICH, which are less commonly affected by spontaneous episodes. Computed tomography (CT) scanning is the most accurate radiological method for demonstrating the acute lesion of intracerebral hemorrhage (ICH). Both types are of high density, but traumatic bleeding is more frequently multifocal, in this study we are dealing with traumatic type of intracerebral hematoma. Aim of the study is to identify the accuracy and performance of CT scan in diagnosis and evaluation of intracerebral hemorrhage.
Patients and methods: 60 patients were examined, their ag

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 22 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Cephalometric analysis of craniofacial deformity of ?-thalassemic major by using computed tomography
...Show More Authors

Background: Thalassemia is a hereditary anemia resulting from defects in hemoglobin production. ?- thalassemia caused by decrease in the production of ?- globin chains affect multiple organs and is associated with cranio-oro-facial deformity which include prominent cheek bones and protrusive premaxilla with depression of the nasal bridge often referred to as “rodent or chip-munk face” with small mandible and Cl.II skeletal relationship. This study aimed to investigate cephalometric craniofacial parameters (skeletal) of ?- thalassemic major patients by using computed tomography and to compare findings with a group of healthy patients in the same age group. Subject, Materials and Method: The study included (40) patients with ?- thalassemi

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Cogent Engineering
IEC 60909 and ANSI standards comparison with ASCC based fault calculations of Iraqi power system
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Ab–Initio large unit cell calculations of the electronic structure of Si and Ge nanocrystals
...Show More Authors

Ab – initio restricted Hartree - Fock method within the framework of large unit cell (LUC) formalism is used to investigate the electronic structure of Si and Ge nanocrystals. The surface and core properties are investigated. A large unit cell of 8 atoms is used in the present analysis. Cohesive energy, energy gap, conduction and valence band widths are obtained from the electronic structure calculations. The results are compared with available experimental data and theoretical results of other investigators. The calculated lattice constant is found to be slightly larger than the corresponding experimental value because we use only 8 atoms and we compared the results with that of the bulk crystals, nanoclusters are expected to have str

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Microscopic calculations of the electric Quadrupole transition strengths of Be isotopes (9, 10, 12, 14)
...Show More Authors

Electric Quadrupole transitions are calculated for beryllium isotopes (9, 10, 12 and 14). Calculations with configuration mixing shell model usually under estimate the measured E2 transition strength. Although the consideration of a large basis no core shell model with 2ℏtruncations for 9,10,12 and14 where all major shells s, p, sd are used, fail to describe the measured reduced transition strength without normalizing the matrix elements with effective charges to compensate for the discarded space. Instead of using constant effective charges, excitations out of major shell space are taken into account through a microscopic theory which allows particle–hole excitations from the core and model space orbits to all higher orbits

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Apr 28 2022
Journal Name
Iraqi Journal Of Science
Microscopic calculations of effective charges and quadrupole transition rates in Si, S and Ar isotopes.
...Show More Authors

Quadrupole transition rates and effective charges are calculated for even-even Si,
S and Ar isotopes based on sd and sdpf -shell model spaces. Shell model
calculations are performed with sd shell-model space for neutron number (N) ≤ 20
and sdpf shell-model space for N > 20. Excitation out of major shell space are taken
into account through a microscopic theory which allows particle-hole excitation
from the core and model space orbits to all higher orbits with 2 excitation.
Effective charges are obtained for each isotope. The results show a systematic
increase in the B(E2) values for N 20. Shell model calculation predicts the erosion
of the N=28 magicity in the neutron rich 42Si. No clear indications abo

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 31 2018
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Ultrasound, computed tomography and surgical observations in the evaluation and staging of the renal cell carcinoma
...Show More Authors

Background: The evaluation and staging of renal cell carcinoma (RCC) has dramatically changed with the introduction of cross-sectional imaging. Nowadays, small renal lesions are easily detected by computed tomography (CT) examination while missed by other modalities.

Objective: To determine whether ultrasound (US) or CT scan is the optimum imaging modality for the evaluation of the renal masses.

Patients and methods: This is a comparative study in which 30 patients with hematuria were attending the urological consulting clinic in Ghazzi Al-Harriry hospital, Baghdad, Iraq from May 2016 to July 2017 were subjected to abdominal US and CT scan.

Results:

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Science
Investigation of the Characteristics of CO (1-0) Line Integrated Emission Intensity in Extragalactic Spirals
...Show More Authors

This paper aims to deal with the understanding of the properties of the molecular gas hydrogen in the extragalactic spirals sample. It is critical to make observations of CO (J = 1-0) line emission for spiral galaxies, particularly those with an energetic nucleus.  In the sample of spiral galaxies compiled, a carbon monoxide CO (1-0) emission line can be observed. This sample of galaxies' gas kinematics and star-forming should be analyzed statistically utilizing appropriate atomic gas HI, molecular gas H2, infrared (1μm-1000μm), visual (at λblue-optical=4400A0), and radio spectrum (at νradio=1.4 GHz and 5GHz) databases. STATISTICA is software that allows us to perform this statistical analysis. The presence of a high scale of s

... Show More
Crossref