A simple and novel method was developed by combination of dispersive liquid-liquid microextraction with UV spectrophotometry for the preconcentartion and determination of trace amount of malathion. The presented method is based on using a small volume of ethylenechloride as the extraction solvent was dissolved in ethanol as the dispersive solvent, then the binary solution was rapidly injected by a syringe into the water sample containing malathion. The important parameters, such the type and volume of extraction solvent and disperser solvent, the effect of extraction time and rate, the effect of salt addition and reaction conditions were studied. At the optimum conditions, the calibration graph was linear in the range of 2-100 ng mL-1 of ma
... Show MoreThe behavior of AC conductivity (σac), loss tangent (tan δ), and relative permittivity (ε′) for composites of PVC-P/graphite electrode waste (GEW) was investigated, and a qualitative explanation was provided as a function of PVC-P weight fractions (0, 5, 10, 15, 20, and 25) wt. percent, temperature (30-90) °C, and frequency (100Hz-2MHz). The behaviors of the composites' ac. conductivity and impedance as a frequency function and temperature have been examined. The permittivity was shown to rise with increasing temperature (Tg). The relative permittivity increased as the GEW filler concentration increased and was highest in the low-frequency range; nevertheless decreased as the frequency increased.
A new colorimetric-flow injection method has been developed and validated for the detection of Cefotaxime sodium in pharmaceutical formulations. This method stands out for its rapid and sensitive nature. The formation of a brown-colored complex between Cefotaxime sodium and the Biuret reagent in a highly alkaline environment serves as the basis for the detection. The intensity of this colored complex is measured using a custom-built Continuous Flow Injection Analyzer, enabling accurate quantification of Cefotaxime sodium. Optimization studies of the chemical and physical parameters such as dilution of Biuret reagent, effect of the medium basicity, flow rate, sample loop and others have been investigated. The calibration gra
... Show MoreReactive Powder Concrete (RPC) is one of the most advanced recent high compressive strength concrete. This work explored the effects of using glass waste as a fractional replacement for fine aggregate in reactive powder concrete at levels of 0%, 25%, 50%, and 100%. Linear and mass attenuation coefficients have been calculated as a function of the sample's thickness and bremsstrahlung energy. These coefficients were obtained using energy selective scintillation response to bremsstrahlung having an energy ranging from (0.1-1.1) MeV. In addition, the half-value thickness of the samples prepared has been investigated. It was found that there is a reversal association between the attenuation coefficient and the energy of the bremsstrahlu
... Show Moreتعد الملابس وسيلة هامة لكل مايقوم به الانسان في حياته العامة ، فهي الانطباع والكلمة الخارجية عن ذاته الداخلية فهي تعكس فكرة الفرد عن ذاته وعن شخصيته , كما تعد وسيلة تعبير جمالية وفنية , فهي تساعد على اخفاء عيوب الجسد وابراز محاسنه . ويتوقف اختيار الفرد لملابسه على مجموعة عوامل منها احتياجه , قدراته المالية , سنه , مركزه الاجتماعي , طبيعة عمله ,الظروف الجوية التي يعيش فيها وعلى مايُؤمن به من قيم و
... Show MoreThis paper deals with the preparation of new monomers and polymers which including heterocyclic unit. The diacid chlorides compounds [1-3] were prepared from the reaction of glutaric acid, adipic acid, terephthalic acid with thionyl chloride. Succinic acid reacted with ethanol to produce compound [4]. Compound [4] reacted with hydrazine hydrate to obtain succinic hydrazide [5].Compound [5] reaction with CS2 and KOH in absolute ethanol to produce compound [6].The polymers [7-12] have been created by reacting diacid chlorides compounds [1-3] with compound[5] or [6] in dry pyridine with some drops of DMF. The topology of produced compounds has characterized through their spectral and analytical data as in FT-IR spectra, Thermal analysis [DSC,
... Show MoreBackground: percutaneous balloon dilation of corotation of aorta is a less invasive and alternative to surgical repair for patients with discrete coaction of aorta and although the used of balloon angioplasty in patients with recurrent postoperative coarctation gained a wide consensus, the use this technique for native coarctation is still controversial in children less one years.
Objective: to evaluate the immediate and late result of balloon dilation of native coarctation of aorta in infant and children.
Type of the study: A prospective study.
Subjects & Methods: The study was done on forty-five patients who were referred for cardiac catheterization and balloon
... Show MoreThe removal of turbidity from produced water by chemical coagulation/flocculation method using locally available coagulants was investigated. Aluminum sulfate (alum) is selected as a primary coagulant, while calcium hydroxide (lime) is used as a coagulant aid. The performance of these coagulants was studied through jar test by comparing turbidity removal at different coagulant/ coagulants aid ratio, coagulant dose, water pH, and sedimentation time. In addition, an attempt has been made to examine the relationship between turbidity (NTU) and total suspended solids (mg/L) on the same samples of produced water. The best conditions for turbidity removal can be obtained at 75% alum+25% lime coagulant at coagulant dose of 80 m
... Show MoreObjective: The evaluation of serum osteocalcin (OSN) for Iraqi infertile patients to see the effect of osteocalcin insufficiency, which may lead to a decreased level of testosterone production in males that may cause infertility. Methods: Forty two newly diagnosed infertile males age range (24–47) years and thirty two apparently healthy males as controls age range (25–58) years. Serum levels of testosterone (TEST), stimulating follicle hormone (FSH) and luteinizing hormone (LH), prolactin (PROL), osteocalcin OSN, and fasting blood sugar (FBS) were performed in both patients and controls. Estimation of serum OSN by Immulite1000 auto-analyzer, TEST, FSH, LH, PROL, and FBS by Immulite2000 auto-analyzer. Results: Infertile patients
... Show More