Preferred Language
Articles
/
GBcsT48BVTCNdQwCpmvX
Spectroscopic study of dielectric barrier discharge argon plasma at different gas flow rates
...Show More Authors

Dielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadening method was used to calculate the electron density (ne). © 2024 American Institute of Physics Inc.. All rights reserved.

Scopus Crossref
View Publication
Publication Date
Sun Dec 29 2019
Journal Name
Iraqi Journal Of Science
Plasma diagnostic of gliding arc discharge at atmospheric pressure
...Show More Authors

A gliding arc discharge (GAD) with a water spray system was constructed. A non-thermal plasma, generated between two V shaped electrodes in an ambient argon driven by 100 Hz AC voltage, was investigated using optical emission spectroscopy (OES) with different gas flow rates (0.5, 1, 1.5, 2 , 2.5 , 3  1/min). Boltzmann plot method was used to calculate electron temperature (Te) and electron density (ne). The electrodes design was spectrally recognized and its Te value was about 0.588-0.863 eV, while the ne value of 6.875×1017-10.938×1017 cm-3. The results of the plasma diagnostics generated by gliding arc showed that increasing gas f

... Show More
View Publication Preview PDF
Scopus (24)
Crossref (9)
Scopus Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
The influence of argon gas flow in the killing of staphylococcus epidermidis bacteria
...Show More Authors

In this research, non-thermal plasma system of argon gas is designed to work at normal atmospheric pressure and suitable for work in medical and biotechnological applications. This technique is applied in the treatment of the Staphylococcus epidermidis bacteria and show the role of the flow rate of Argon gas on the killing rate of bacteria, and it obtained a 100 % killing rate during the time of 5 minutes at the flow Argon gas of 5 liters/ min.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Argon plasma needle source
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded

View Publication Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Effect of Recirculation Ratio on the Uniformity Flow in a High Area Ratio of Outlets Pipe at Different Entrance flow rates
...Show More Authors

The uniform flow distrbiution in the multi-outlets pipe highly depends on the several parameters act togather. Therefor, there is no general method to achieve this goal. The  goal of this study is to investigate the proposed approach that can provide significant relief of the maldistribution. The method is based on re-circulating portion of flow from the end of the header to reduce pressure at this region . The physical model consists of main manifold with uniform longitudinal section having diameter of 152.4 mm (6 in), five laterals with diameter of 76.2 mm (3 in), and spacing of 300 mm. At first, The experiment is carried out with conventional manifold, which is a closed-end. Then, small amount of water is allowed

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Influence of Glow and Afterglow Times on the Discharge Current of Argon at Low Pressure
...Show More Authors

     An experimental investigation of the variation of argon discharge current with a glow and afterglow time intervals of a square discharge voltage was carried out at low pressure (6-11 mbar). The discharge was created between two circular metal electrodes of diameter (7.5 cm), separated horizontally by a distance (10 cm) at the two ends of a Pyrex cylindrical tube. A composite of two Gaussian functions has been suggested to fit and explain the variation graphs clearly. It is shown that the necessary times of glow and afterglow needed to attain a maximum discharge current are (70 us) and (60 us), respectively. The discharge current is observed to drop to the lowest value when the two times are serially longer than (85 us) and (72 u

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Feb 08 2023
Journal Name
Iraqi Journal Of Science
Magnetic Field Effect on the Characteristics of Large-Volume Glow Discharge in Argon at Low Pressure
...Show More Authors

The magnetic field effect on the current-voltage characteristic curves of glow discharge in argon at low pressures has been experimentally investigated. The electrical discharge was ignited in a stainless steel tapered chamber of a nominal volume of 0.5m3 immersed inside a water-cooled coil capable of delivering a magnetic field of strength B of up to 0.42T. Three water-cooled electrodes were inserted into the chamber up to a point where their tips were 20cm away from the surface of the central column of the chamber. An enhancement of the electric field configuration within the region of the electrode assembly was performed by threading one of the electrodes with stainless circular discs(80mm and 140mm in diameter) in various forms(attac

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave
...Show More Authors

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

View Publication Preview PDF
Scopus (11)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Effects of Gas Flow on Spectral Properties of Plasma Jet Induced by Microwave
...Show More Authors

In this paper, a construction microwave induced plasma jet(MIPJ) system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate using flow meter regulator. The influence of the MIPJ parameters such as applied voltage and argon gas flow rate on macroscopic microwave plasma parameters were studied. The macroscopic parameters results show increasing of microwave plasma jet length with increasing of applied voltage, argon gas flow rate where the plasma jet length exceed 12 cm as maximum value. While the increasing of argon gas flow rate will cause increasing into the ar

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Correlation of Paschen parameters in magnetized argon plasma
...Show More Authors

A number of glow discharge experiments has been carried out in a relatively large-volume metallic vacuum chamber containing argon at low pressure and immersed in an inhomogeneous magnetic field generated by a solenoidal coil capable of delivering 2100G. Two Paschen curves demonstrating the dependence of the discharge voltage on sparking parameter Pd and magnetic field strength B were deduced. A graphical correlation showing the behaviour of the voltage difference from the two curves on the ratio B/Pd was constructed. Investigations showed a reduction in the nominal impedance of the discharge device of nearly 20% when B reaches a value of 525G. Plasma confinement regions were found around the internal surface of the chamber at the entranc

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
Effects of Non-Thermal Argon Plasma Produced at Atmospheric Pressure on the Optical Properties of CdO Thin Films
...Show More Authors

In this paper the effect of nonthermal atmospheric argon plasma on the optical properties of the cadmium oxide CdO thin films prepared by chemical spray pyrolysis was studied. The prepared films were exposed to different time intervals (0, 5, 10, 15, 20) min. For every sample, the transmittance, Absorbance, absorption coefficient, energy gap, extinction coefficient and dielectric constant were studied. It is found that the transmittance and the energy gap increased with exposure time, and absorption. Absorption coefficient, extinction coefficient, dielectric constant decreased with time of exposure to the argon plasma

View Publication Preview PDF
Scopus (17)
Crossref (9)
Scopus Clarivate Crossref