Background: The estimation of ferritin and related variables by complete serum iron profile, for Iraqi hashimoto’s patients to see the effect of thyroid hormone insufficiency, which may lead to deficiency of ferritin iron stores, this may be quite useful during the diagnosis and treatment of hashimoto’s patients. Patients and Method: The study was performed at National Center of Teaching laboratories of Medical city institute in Baghdad. Fifty newly diagnosed patients with hashimoto’s and forty apparently healthy controls. Diagnosis based on thyroid profile analysis including:Thyroid Stimulating Hormone (TSH), Thyroxine (totalT4) and Triiodothyronine (total T3), estimation of antibodies against thyroperoxidase, iron profile including: serum ferritin, serum iron, total iron-binding capacity (TIBC), unsaturated iron-binding capacity (UIBC) and Transferrin saturation (TSAT) for both groups. Result: The hashimoto’s patients have elevated levels of anti-TPO, TSH, TIBC, UIBC and TSATas compared with controls. Anti-TPO, TSH, UIBC and TSAT were significantly higher than that of controls, while TIBC is not significant. In other hand, hashimoto’s patients have lowered levels of Total T3, Total T4, Ferritin and Iron as compared with controls. Total T4, Ferritin and Iron were significantly lower than that of control,while TotalT3 is not significant. Conclusion: Statistical application for the current study by employing Receiver Operation Characteristic curve (ROC curve) shows the validaty of anti-TPO in addition to serum iron and total T4 to be used as a biomarkers for detection of hashimoto’s thyroiditis.
Beata thalassemia
Beta thalassemia syndrome by reduction or absence of B-globin chain synthesis. Without iron chelation therapy (ICT) the regular blood transfusion would increase the iron stores to several times. Endocrine glands are vulnerable to iron overload causing endocrine dysfunction. Iron deposition within the parathyroid gland causes hypoparathyroidism particularly after ten years of age. Pancreatic islets are very susceptible to oxidative damage due to iron overload; their high divalent metal expression makes them highly susceptible to iron-catalyzing oxidative stress. The pathogenicity of osteopathy in is multifactorial comprising environmental (diet and lifestyle), iatrogenic (medicines), genetic and acqui
... Show MoreArchives of Razi Institute (ARI)
From 124 women in different stage of pregnancy ,there were 83 (67%) conceded
anemic and 41(33%) were non anemic ,there were 54(65%) suffering from iron
deficiency anemia. According to the form of anemia , 27 (32.5%) were suffering
from mild anemia, 41 (49.4%) moderately anemia while15 (18.1%) severe anemia
The number of anemic pregnant women from Baghdad was 39 (47%) and the
internally displaced anemic pregnant women 44 (53%). the anemic pregnant women
who were primigravida 36 (43.4%), while the pregnant women who were multipart
gravida 47 (56.6%) .The number of anemic pregnant women was 26(31.3%) for age
of 17-27y ,33(39.8%) for age of 28-37y and 24(28.9% )for age of 38-45y .while the
number of anemic pregnant
Iron-Epoxy composite samples were prepared by added
different weight percentages (0, 5, 10, 15, and 20 wt %) from Iron
particles in the range of (30-40μm) as a particle size. The contents
were mixed carefully, and placed a circular dies with a diameter of
2.5 cm. Different mechanical tests (Shore D Hardness, Tensile
strength, and Impact strength ) were carried out for all samples. The
samples were immersed in water for ten weeks, and after two weeks
the samples were take-out and drying to conducting all mechanical
tests were repeated for all samples. The hardness values increased
when the Iron particle concentration increased while the Impact
strength is not affected by the increasing of Iron particles
c
This study investigated the applicability of iron oxide (Fe2O3) nanoparticles for the removal of cadmium metal from sewage water by using batch scale experiments. The iron oxide nanoparticles of 27.7nm were synthesized using a biological method and characterized by Atomic Force Microscope (AFM). The Box-Wilson design was used to conduct experiments with three parameters such as pH (2-6), time of adsorption (6-120min) and adsorbent dosage (5-25mg/L). The best conditions occurred at pH: 5.5; contact time: 95.8 min; and iron oxide nanoparticle dosage: 20.77 mg/L for maximum cadmium removal of (96.9%).
Background: occult blood loss must be considered as a
possible cause in every case of iron deficiency anemia.
Objective: to evaluate upper gastrointestinal endoscopy
in finding a potential cause for iron deficiency anemia
among children in Al-Anbar governorate.
Methods: Twenty five children aged 2-14 years, referred
to the gastroenterology unit in Al-Ramadi General Hospital
for upper gastrointestinal endoscopy had iron deficiency
anemia. Fiberoptic endoscopy was used under general
anesthesia and endoscopic tissue biopsies were taken from
22 patients for histopathological examination.
Results: The main presenting signs and symptoms were
pallor, abdominal pain, and stunting. The upper
gastrointestinal
In this paper, two types of iron oxide nanomaterial (Fe3O4) and nanocomposite (T-Fe3O4) were created from the bio-waste mass of tangerine peel. These two materials were utilized for adsorption tests to remove cefixime (CFX) from an aqueous solution. Before the adsorption application, both adsorbents have been characterized by various characterizations such as XRD, FTIR, VSM, TEM, and FESEM. The mesoporous nano-crystalline structure of Fe3O4 and T-Fe3O4 nanocomposite with less than 100-nm diameter is confirmed. The adsorption of the obtained adsorbents was evaluated for CFX removal by adjusting several operation parameters to optimize the removal. The optimal conditions for CFX removal were found to be an initial concentration of 40 and 50 m
... Show MoreElectrocoagulation is an electrochemical method for treatment of different types of wastewater whereby sacrificial anodes corrode to release active coagulant (usually aluminium or iron cations) into solution, while simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation or settling. The Taguchi method was applied as an experimental design and to determine the best conditions for chromium (VI) removal from wastewater. Various parameters in a batch stirred tank by iron metal electrodes: pH, initial chromium concentration, current density, distance between electrodes and KCl concentration were investigated, and the results have been analyzed using signal-to-noise (S/N) ratio. It was found that the r
... Show MoreA research was conducted to determine the feasibility of using adsorption process to remove boron from aqueous solutions using batch technique. Three adsorbent materials; magnesium, aluminum and iron oxide were investigated to find their abilities for boron removal. The effects of operational parameters on boron removal efficiency for each material were determined.
The experimental results revealed that maximum boron removal was achieved at pH 9.5 for magnesium oxide and 8 for aluminum and iron oxide. The percentage of boron adsorbed onto magnesium,aluminum and iron oxide reaches up to 90, 42.5 and 41.5% respectively under appropriate conditions. Boron concentration in effluent water after adsorption via magnesium oxide comply with th
In this research the electrical conductivity and optical measurements were made on the Iron Oxide (Fe2O3) films prepared by chemical spray pyrolysis method as a function of thickness (250, 350, 450, and 550)  20 nm. The measurements of electrical conductivity (σ), activation energies (Ea1, Ea2),and optical constant such as absorption coefficient, refractive index, extinction coefficient and the dielectric constants for the wavelengths in the range (300-900) nm have been investigated on (Fe2O3) thin films as a function of thickness. All films contain two types of transport mechanisms, and the electrical conductivity (σ) increases whereas the activation energy (Ea) would decrease as the films thi
... Show More