A major disadvantage of dose reconstruction by means of thermoluminescence (TL) is the fact that during readout of any TL material exposed to ionizing radiation (i.e., during measuring the glow curve), the radiation-induced signal gets lost. Application of the photo-transferred thermoluminescence phenomenon (PTTL) may offer a solution to this problem. In PTTL, the residual signal that is not destroyed by conventional TL readout (because it comes from deeper electron traps) can be readout through simultaneous stimulation by UV light and heating, allowing to obtain information about the absorbed dose in a second run. The present paper describes the application of PTTL for emergency dose assessment. For this, MTS-N thermoluminescent detectors (LiF: Mg, Ti) were exposed using a high-energy Clinac 2300 medical linear accelerator to doses of 100 mGy, 300 mGy, 500 mGy, 700 mGy and 1000 mGy. Irradiation with UV radiation allowed the determination of the optimal heating time of 3 h, while the optimal temperature was identified to be 70 °C. The results obtained demonstrated the usefulness of the PTTL method for emergency dose assessment. The efficiency of the PTTL method was determined as 19%. Finally it was found that the detector background after UV exposure should not be underestimated during routine dose measurements.
One of the Iraqi geotechnical problems is the presence of gypseous soils covering about (27-36) percentage of Iraq soils containing gypsum between (10-70) ratios. The main reason for soil problematic is the gypsum dissolution when these soils are inundated. However, the soluble gypsum can be leached out of the soil particles, so these problems can be led to cracking, tilting, and collapsing the related soil structure and changing the soil properties. The aim of this work is to investigate the performance of under-reamed piles as a new, improved method to reduce the moisture sensitive and the primary triggering mechanism for the volume reduction of collapsible soil, which is considered as a non-elastic deformation; this was done by c
... Show MoreThe rhetoric is concerned with the expressive emphasis of things, the science of the statement takes the treatment of graphic images and rhetorical fiction, and in the science of the exquisite dealing with the study of verbal and moral improvements, and in the science of meanings took all related to compositions and methods, and these vocabulary entered into the field of art and its branches largely, especially in the uncle and art of design because it has a major role in including a lot of biological functions with a deep meaning of its comprehensiveness on the multiplicity of real meanings characterized by suggestive and important and semantics refer to the recipient in the research to refer to the recipient The discovery of the intern
... Show MoreIn this paper, we define a cubic positive implicative-ideal, a cubic implicative-ideal and a cubic commutative-ideal of a semigroup in KU-algebra as a generalization of a fuzzy (positive implicative-ideal, an implicative-ideal and a commutative-ideal) of a semigroup in KU-algebra. Some relations between these types of cubic ideals are discussed. Also, some important properties of these ideals are studied. Finally, some important theories are discussed. It is proved that every cubic commutative-ideal, cubic positive implicative-ideal, and cubic implicative-ideal are a cubic ideal, but not conversely. Also, we show that if Θ is a cubic positive implicative-ideal and a cubic commutative-ideal then Θ is a cubic implicative-ideal. Some example
... Show MoreThe gamma camera, along with SPECT and PET scanners, is one of the main imaging technologies in nuclear medicine. A collimator is typically constructed from tungsten to provide high absorption of gamma photon energies. It has a hole or holes for imaging. Gamma rays from a radioactive source within the body are emitted in all directions, while the photons required constructing an image travel through the hole. A scintillator is the most common material used to convert the high energy of gamma radiation into a lowenergy optical photon. These detectors are one of the primary secrets to radio-diagnosis in nuclear medicine. The photomultiplier tube (PMT) is a versatile device with extraordinarily highly sensitivity and response. A typical photom
... Show MoreVarious Hall Effects have been successfully observed in samples of n-type indium antimonide with values for conductivity, energy gap, Hall mobility and Hall coefficient all agreeing with theory. A particular interest in developing a method for obtaining accurate values of carrier concentrations in semiconductor samples has been fulfilled with an experimental result of (1.6×1016 cm-3 ±10.7%) giving a percentage difference of (6.7%) to a quoted value of (1.5×1016cm-3) at (77K) using an (80mW C.W. CO2) laser beam at (10.6μm) to illuminate a similar sample of n-type indium antimonide, an "Optical" Hall effect has been observed. Although some doubt has been raised as to the validity of effect i.e. "thermal" rather than "Optical", values o
... Show MoreA simple, rapid, accurate and sensitive spectrophotometric method for the determination of thiaminehydrochloride has been developed. The method is based on the formation of the Schiff’s base between the primary amino group present in thiamine hydrochloride and aldehyde group present in the vanillin reagent to produce a yellow colored complex having maximum absorption at 390 nm. Beer’s law has obeaid over the concentration range of 2-28µg/mL, with molar absorptivity of 0.96x104L/mol.cm. The average recovery which is a measure of accuracy is 100±1.3% and the relative standard deviation (RSD) is less than1.5 .The present method is considered to be
... Show MoreReview of multidrug sensitivity and resistance in enterococcus